About this model

The ABB ACS800

The ACS800 is ABB's long-running industrial AC drive, found across Indian cement, steel, paper, water and chemical plants on pumps, fans, conveyors, extruders and winders. It comes as wall-mounted single drives, free-standing cabinet drives and multidrive line-ups sharing a common DC bus, and many units in service today have been running for well over a decade.

ABB has moved new projects to the ACS880, so ACS800 spares are getting harder to find. Component-level repair keeps these drives running without re-engineering the panel or the process: the failed stage, whether an IGBT module, DC capacitors, a fan, a gate-drive board or the control unit, is found and replaced, and the drive is tested on its own motor and load.

Engineers on MachineryFix work on the full ACS800 range. An engineer can come to the plant from our Hyderabad base, or the drive or the failed module can be sent to MachineryFix from anywhere in India and routed to an engineer who works on ACS800s.

Common faults

What goes wrong on the ACS800

  • Overcurrent and short-circuit trips

    An ACS800 that trips on overcurrent at start, or reports a short circuit, usually has a failed IGBT, a damaged motor cable or a motor insulation fault. The motor and cable are tested with the drive disconnected before the power stage is opened.

  • DC overvoltage on deceleration

    Fast deceleration of high-inertia loads such as fans and centrifuges pushes energy back into the DC link. A failed braking chopper or resistor, or a deceleration ramp set too short, causes the trip.

  • Overtemperature

    Blocked air paths, failed cooling fans and hot electrical rooms. ACS800 cooling fans have a finite life and are a routine replacement on older drives; a drive that overheats in summer often just needs its fans and filters attended to.

  • Earth faults

    Insulation breakdown in the motor or cable, moisture in a terminal box during the monsoon, or a failing current measurement circuit inside the drive. Insulation is measured with the motor isolated from the drive.

  • Supply and charging faults

    Supply phase loss, a failing input stage or ageing DC capacitors show up as supply or undervoltage faults, often after a power disturbance.

Fault codes

ACS800 fault codes

Codes and names as ABB lists them; the explanations are ours. Check the manual for your firmware version before acting on a code.

  • 2310

    OVERCURRENT

    Output current exceeded the trip limit. Check the load and acceleration ramp first; if it trips at start with no load, suspect the power stage or motor cable.

  • 2330

    EARTH FAULT

    Current is leaking to earth. Test motor and cable insulation with the drive disconnected before resetting.

  • 2340

    SHORT CIRC

    A short circuit in the motor, cable or output stage. Do not reset repeatedly; this often means a failed IGBT or a cable fault.

  • 3130

    SUPPLY PHASE

    The intermediate circuit voltage is oscillating, usually from a missing supply phase or a blown input fuse.

  • 3210

    DC OVERVOLT

    The DC link voltage is too high, typically during deceleration. Check the braking chopper and resistor and the deceleration time.

  • 3220

    DC UNDERVOLT

    The DC link voltage is too low: a supply dip, a missing phase or a failing input stage.

  • 4210

    ACS800 TEMP

    The drive's power stage is too hot. Check cooling fans, filters, heatsink cleanliness and the room temperature.

  • 4310

    MOTOR TEMP

    The motor temperature model or sensor reports overheating: overload, poor motor cooling or wrong motor data.

  • 5300

    PANEL LOSS

    The control panel selected as the control location has stopped communicating: a loose panel, cable or connector.

  • 7121

    MOTOR STALL

    The motor is running in the stall region: a jammed load, a brake not releasing or limits set too low.

First checks

What to check before calling an engineer

Safe for plant staff

  • Read the fault code and fault history from the control panel, and note what the drive was doing when it tripped.
  • Check that the cooling fans run and that filters and heatsinks are not blocked with dust.
  • Check whether other drives on the same supply tripped at the same time, which points to the supply.
  • Disconnect the motor and test its insulation with a suitable tester before restarting after an earth or short-circuit fault.

Leave to a specialist

  • Any work inside the drive: ACS800 DC links hold a dangerous charge after isolation and need the waiting time in the manual.
  • Replacing IGBT modules, capacitors, gate-drive or control boards.
  • Changing motor data, control mode or protection parameters on a drive running a critical process.
  • Work on multidrive line-ups that share a DC bus with other drives.

Getting it fixed

How to get a ACS800 repaired

Technicians work onsite from our Hyderabad base and travel to plants across India; anything that can be removed can also be sent to MachineryFix from anywhere in the country. The diagnosis and repair cost are confirmed before any work starts.

Warranty. Repairs carry a warranty of 30 days to 6 months, depending on the item and the repair; the exact term is confirmed before work starts.

FAQ

ACS800 repair questions

Is the ACS800 still worth repairing now that ABB sells the ACS880?+

Usually, yes, for drives that are otherwise healthy. Repair keeps the panel, cabling and settings unchanged and avoids an engineering project. Where a drive keeps failing or spares can't be found, the engineer will say so and outline a migration to a current drive.

Can an ACS800 be repaired onsite?+

Fan, capacitor and many board replacements can be done onsite. Power-stage repairs on larger drives are often done on a bench and the drive or module refitted. Either way, it is tested on the motor and load before handover.

How do I send an ACS800 for repair?+

Send the drive or the failed module to MachineryFix with the model, rating and fault code. It is routed to an engineer who works on ACS800s, and the diagnosis and repair cost are confirmed before any work starts.

Will our parameters be kept?+

Parameters are read and saved before work where the drive allows it, and restored afterwards. If the control unit has failed, settings are rebuilt from your records or the motor and process data.

Is there a warranty on the repair?+

Yes. Repairs carry a warranty of 30 days to 6 months, depending on the item and the repair; the exact term is confirmed before work starts.

Same manufacturer

Other ABB AC Drives & VFDs

ABB and ACS800 are named only to identify the equipment. MachineryFix is not affiliated with or endorsed by ABB.

ACS800 down?