VFD keeps tripping on overcurrent or overvoltage?
Likely causes, what our technicians check onsite, and how to get it fixed — verified engineers across India, onsite in hours (under 4 in Hyderabad), 24/7.
01 / Overview
VFD Keeps Tripping
A VFD that trips repeatedly is reporting a specific fault — overcurrent (OC), overvoltage (OV), overtemperature (OH), ground fault (GF) or undervoltage (UV) — and each points at a different cause. Clearing the fault and restarting without diagnosing it just repeats the trip, sometimes until something lets go.
We repair and re-parameterise every major drive — Siemens SINAMICS/MICROMASTER, ABB ACS, Schneider Altivar, Allen-Bradley PowerFlex, Mitsubishi FR, Delta and Yaskawa — reading the fault history and testing the power stage, DC bus, cooling and motor before we quote.
02 / Diagnosis
Likely causes
The handful of things that actually cause this — in the order we rule them out.
Overcurrent (OC)
A failing IGBT leg, a shorted or breaking-down motor winding, a too-aggressive acceleration ramp, or a mechanical jam. We meter the IGBT stage and megger the motor to separate drive from motor.
Overvoltage (OV)
Usually a braking problem — a decelerating load regenerating energy with an open or missing brake resistor/chopper — or supply overvoltage. Common on high-inertia loads with short deceleration times.
Overtemperature (OH)
A clogged heatsink or a dead cooling fan, the single most common repeat-trip in dusty plant. The drive is fine; it just can't shed heat.
Ground fault (GF)
Current leaking to earth on the output side — a motor winding breaking down to frame, or a damaged/damp output cable. Far more often a motor/cable fault than a drive fault.
Undervoltage (UV)
Supply-side: phase loss, a loose incoming termination, or voltage sag when a big load starts elsewhere. Occasionally a failed pre-charge circuit in the drive.
03 / Onsite
What our technician checks
A methodical path to root cause — not a scattergun of part swaps.
- 01Read the fault history and identify the exact trip code
- 02Meter the IGBT power stage and DC-bus capacitors
- 03Megger the motor and output cable for shorts and ground faults
- 04Inspect heatsink, cooling fan and ambient conditions
- 05Review ramp times, current limits and brake-circuit parameters
04 / Fix it
Related services
The services that resolve this fault.
05 / Questions
Frequently asked questions
My VFD trips on overcurrent every time I start. Is the drive faulty?+
Is it cheaper to repair the VFD or replace it?+
Written & reviewed by MachineryFix Engineering Team — last reviewed — questions? Call +91 70751 47888