What VFD repair actually involves
A variable frequency drive that trips on overcurrent, throws a DC bus fault or refuses to start usually fails for one of a small number of reasons — a shorted IGBT module, a degraded DC bus capacitor bank, a failed cooling fan, or a motor-side insulation fault that the drive is correctly reporting as its own problem.
Our technicians carry drive test equipment to site, so the first job is always deciding whether the fault is in the drive, in the motor, or in the cable between them. That distinction changes the repair entirely and is the step most often skipped.
02 / On site
What the technician does
Board-Level Repair
IGBT and rectifier module replacement, gate driver repair, DC bus capacitor reforming and replacement.
Motor-Side Isolation
Insulation resistance and winding tests to confirm whether the drive or the motor is actually at fault.
Parameter Recovery
Drive parameters read, documented and restored after repair or replacement, so the machine runs as it did before.
03 / Error codes
VFD error codes we fix on site
If your display shows one of these, send us the code. Each one links to what it means and why it happens.
- OvercurrentF30001 · 2310 · OCF · E.OC1 / E.OC2 / E.OC3 · oC · Alarm 13
- DC bus overvoltageF30002 · 3210 · ObF · E.OV1 / E.OV2 / E.OV3 · ov · Alarm 7
- UndervoltageF30003 · 3220 · USF · E.UVT · Uv1 · Alarm 8
- Drive overtemperatureF30004 · 4210 · OHF · E.FIN · oH · Alarm 29
- Motor overloadOLF · E.THM · oL1 · Alarm 10
- Drive overloadF30005 · E.THT · oL2 · Alarm 9
- Earth faultF30021 · 2330 · E.GF · GF · Alarm 14
- Input phase lossF30011 · 3130 · PHF · PF · Alarm 4
- Output phase loss3381 · OPF · E.LF · LF
04 / How it works
What happens when you get in touch
- 01Call or WhatsApp us with the machine, the fault code if there is one, and where the plant is.
- 02We match a technician who works on this kind of equipment, and they review the code before setting out.
- 03On site they make it safe, diagnose, and tell you what has failed and what the repair involves before starting.
- 04After the repair they run the machine with you, and you sign off a job card and get a report for your records.
Questions
VFD Repair: questions we get asked
Why does the VFD trip on overcurrent at startup?+
Most often a shorted IGBT, a motor winding or cable insulation failure, or an acceleration ramp set too aggressively for the load's inertia. Mechanical binding on the driven equipment produces the same symptom, so the load is checked before any parameter is changed.
What causes an overvoltage fault during deceleration?+
A decelerating load feeds regenerated energy back into the DC bus. If the deceleration ramp is too short, or the braking resistor or braking chopper has failed, the bus voltage rises past the trip threshold. The braking circuit is checked before the ramp is extended.
Is a failed drive worth repairing or should it be replaced?+
It depends on power-stage damage, control-board condition, spare availability and whether the model is still supported. A drive with a failed fan or capacitor bank is almost always worth repairing; one with a destroyed power stage on an obsolete platform often is not.
Which VFD brands do you repair?+
Siemens, ABB, Schneider, Mitsubishi, Delta, Yaskawa, Danfoss, Allen-Bradley and most other drives found in Indian plants, including older models no longer sold. Tell us the make and model from the rating plate when you get in touch.
How much does VFD repair cost?+
It depends on what has failed. A cooling fan or a parameter fault is a small job; a failed power stage is a large one, and sometimes replacement is the better choice. The technician diagnoses first and tells you what is wrong and what it will cost before any work starts.
Can I send the fault code before anyone comes?+
Yes, and it helps. Send the code, the drive model and a photo of the display on WhatsApp. Often the code alone narrows the fault to the drive, the motor or the cable, so the technician arrives with the right test equipment and spares.
Do you repair the drive on site or take it away?+
Diagnosis, parameter work, fan and many board-level faults are handled on site. A drive that needs power-stage rework is sometimes taken to the bench, and you are told before it leaves the plant.