Wirtgen Group · Excitation & Generator Controls
Wirtgen Group 121344 repair
Get the Wirtgen Group 121344 repaired rather than replaced. It is matched to an engineer who works on Wirtgen Group excitation or generator controls, and the cost is confirmed before work starts.
Cost confirmed before any work starts · Warranty of 30 days to 6 months
At a glance
The Wirtgen Group 121344
- Manufacturer
- Wirtgen Group
- Model / part number
- 121344
- Description
- Joystick
- Category
- Excitation & Generator Controls
- Service
- Diagnosis and component-level repair, onsite or ship-in
- Warranty
- 30 days to 6 months, confirmed before work starts
Wirtgen Group equipment in this catalog is listed by model or part number. Send the model from the nameplate and the fault, and it will be matched to an engineer who works on that kind of unit.
Common faults
What usually fails on a unit like the 121344
Excitation systems and generator controls regulate voltage and protect the generator, so faults show up as unstable voltage, field failures or tripping on load. AVR boards, thyristor bridges, controllers and engine control units can be repaired and tested.
Voltage hunting or instability
AVR control faults, sensing problems or worn feedback components.
Field failure and loss of excitation
Failed field thyristors or diodes, firing circuits or a fault in the exciter.
Overvoltage or undervoltage trips
Sensing circuit faults or wrong settings after a board change.
Controller and display faults
Dead controllers, lost settings and failed communication with switchgear.
Engine control unit faults
Speed control, sensor input and actuator driver faults on gensets.
First checks
What to check before calling an engineer
Isolate and lock out the supply, and wait for stored energy to discharge, before opening anything.
Safe for plant staff
- Record alarms and event logs from the controller.
- Note the load and conditions when the fault appeared.
- Keep a copy of the controller settings.
Leave to a specialist
- Work on the field circuit or exciter.
- AVR tuning and setting after repair.
- Any test on a running generator.
Getting it fixed
How to get the 121344 repaired
What to send with it
- The AVR, exciter board or controller.
- The generator rating and the alarm or log.
- Its settings, if they can be read out.
Onsite or ship-in
Technicians work onsite from our Hyderabad base and travel to plants across India; anything that can be removed can also be sent to MachineryFix from anywhere in the country.
Warranty. Repairs carry a warranty of 30 days to 6 months, depending on the item and the repair; the exact term is confirmed before work starts.
FAQ
121344 repair questions
Does the Wirtgen Group 121344 need setting up after repair?+
Usually its settings are kept, but voltage regulation and any limits should be checked on the generator when it is refitted.
Does the Wirtgen Group 121344 have to be sent in, or can an engineer come to the plant?+
Either. An engineer can diagnose it in place and repair it there or take it away, or the unit can be sent to MachineryFix from anywhere in India. The diagnosis and repair cost are confirmed before any work starts.
Is MachineryFix connected to Wirtgen Group?+
No. Wirtgen Group and the model name are used only to identify the equipment. MachineryFix is an independent repair service and is not affiliated with or endorsed by Wirtgen Group.
Same manufacturer
Other Wirtgen Group Excitation & Generator Controls
Other manufacturers
Excitation & Generator Controls from other makers
Wirtgen Group and 121344 are named only to identify the equipment. MachineryFix is not affiliated with or endorsed by Wirtgen Group.
121344 down?
Send the fault and what the machine was doing. We'll match an engineer who works on it.