273 models · 33 manufacturers
Protection Relays repair
Numerical and electromechanical protection relays for motors, feeders, generators and transformers. Protection relays have to trip when needed and stay quiet otherwise, so a repaired relay must be tested against its settings, not just powered up. Power supplies, input boards, displays and output contacts are the usual failure points.
Manufacturers
Protection Relays by manufacturer
Models
Protection Relays in the catalog
A selection. Pick a manufacturer above for the full list, or search by part number at the top of the catalog.
| Model / part | Manufacturer | Actions |
|---|---|---|
| 3SK1220-2AB40Safety relay | Siemens | |
| 4600Digital display controller | ABB | |
| 462-M51-H21-ASafety relay | Elobau | |
| 489Relay, generator management 489-P5-LO-A20-E | GE Power Management | |
| 79-81-026-715Kit, 3S power realy | Mann + Hummel | |
| 7SA86 P1A39686Relay, siprotec multifunction protection | Siemens | |
| 7SJ6001-4EA00-0DA0-BBRelay | Siemens | |
| 7SJ6101-5BB39-2BA0-DD M2BSiprotec relay | Siemens | |
| 7SJ62Relay, siprotec multifunction protection 7SJ6211-4EN22-1FE0/CC | Siemens | |
| 7SJ62Relay, siprotec multifunction protection 7SJ6211-4EN22-3HF0/CC | Siemens | |
| 7SJ62Relay, siprotec multifunction protection 7SJ6211-5EB90-1FE0/GG | Siemens | |
| 7SJ62Relay, siprotec multifunction protection 7SJ6211-1FE0-3HF0/CC | Siemens | |
| 7SJ63Relay, siprotec multifunction protection 7SJ6311-4EE22-3HF0 I -CC | Siemens | |
| 7SJ66Protective relay | Siemens | |
| 7SK85 P1H4963Relay, siprotec multifunction protection | Siemens | |
| 7SK85 P1H5829Relay, siprotec multifunction protection | Siemens | |
| 7SS5220-5AB90-1BA0/HHUnit, busbar protection siprotec | Siemens | |
| 7SS5251-5FA01 -0AA1/FFBusbar siprotec | Siemens | |
| ARGUS 7SR1003-1KA20-2CA0-DDOvercurrent relay | Siemens | |
| BAP-SIG-RELAY-4-00-114-229925Relay card | Phoenix Contact | |
| BCG-C0E1-B1A0-C0A0-A1SYMAP BCG relay | Stucke Elektronik | |
| Card, tanker earth relay monitoring earth rite II RTR | Newson Gale | |
| Control card, receiver relay | Itowa | |
| D70EU00936 YM11ASafety relay unit | Mazak | |
| DMUB8D1BLMotor, DC 8P 750W DC 280V | Panasonic | |
| DRS-C2AGenerator protection relay | Elin | |
| DU3-206-EB-50EDuobias-m | Easun Reyrolle | |
| ECG-A2K0-B0A0-A5F0-B0SYMAP ECG relay | Stucke Elektronik | |
| EX-RM1Relay module | Lutz | |
| F650Relay, multilin feeder protection F650MOD001 | GE |
- 3SK1220-2AB40Safety relay · Siemens
- 4600Digital display controller · ABB
- 462-M51-H21-ASafety relay · Elobau
- 489Relay, generator management 489-P5-LO-A20-E · GE Power Management
- 79-81-026-715Kit, 3S power realy · Mann + Hummel
- 7SA86 P1A39686Relay, siprotec multifunction protection · Siemens
- 7SJ6001-4EA00-0DA0-BBRelay · Siemens
- 7SJ6101-5BB39-2BA0-DD M2BSiprotec relay · Siemens
- 7SJ62Relay, siprotec multifunction protection 7SJ6211-4EN22-1FE0/CC · Siemens
- 7SJ62Relay, siprotec multifunction protection 7SJ6211-4EN22-3HF0/CC · Siemens
- 7SJ62Relay, siprotec multifunction protection 7SJ6211-5EB90-1FE0/GG · Siemens
- 7SJ62Relay, siprotec multifunction protection 7SJ6211-1FE0-3HF0/CC · Siemens
- 7SJ63Relay, siprotec multifunction protection 7SJ6311-4EE22-3HF0 I -CC · Siemens
- 7SJ66Protective relay · Siemens
- 7SK85 P1H4963Relay, siprotec multifunction protection · Siemens
- 7SK85 P1H5829Relay, siprotec multifunction protection · Siemens
- 7SS5220-5AB90-1BA0/HHUnit, busbar protection siprotec · Siemens
- 7SS5251-5FA01 -0AA1/FFBusbar siprotec · Siemens
- ARGUS 7SR1003-1KA20-2CA0-DDOvercurrent relay · Siemens
- BAP-SIG-RELAY-4-00-114-229925Relay card · Phoenix Contact
- BCG-C0E1-B1A0-C0A0-A1SYMAP BCG relay · Stucke Elektronik
- Card, tanker earth relay monitoring earth rite II RTRNewson Gale
- Control card, receiver relayItowa
- D70EU00936 YM11ASafety relay unit · Mazak
- DMUB8D1BLMotor, DC 8P 750W DC 280V · Panasonic
- DRS-C2AGenerator protection relay · Elin
- DU3-206-EB-50EDuobias-m · Easun Reyrolle
- ECG-A2K0-B0A0-A5F0-B0SYMAP ECG relay · Stucke Elektronik
- EX-RM1Relay module · Lutz
- F650Relay, multilin feeder protection F650MOD001 · GE
Common faults
What usually fails on Protection Relays
Relay dead or rebooting
Failed internal power supply, often from age or a surge on the auxiliary supply.
Self-supervision or internal fault alarms
Faults in the processor board, memory or analog input stages.
Wrong measurement
Current or voltage inputs reading wrongly because of damaged input transformers or analog circuits.
Output contacts not operating
Burnt or welded output relay contacts, or failed driver circuits.
Display and keypad faults
Unreadable displays and dead keys, which make settings hard to check.
First checks
What to check before calling an engineer
Isolate and lock out the supply, and wait for stored energy to discharge, before opening anything.
Safe for plant staff
- Record any self-supervision alarm and the event log.
- Check the auxiliary supply voltage.
- Keep a copy of the settings file.
Leave to a specialist
- Secondary injection testing after repair.
- Changing or uploading relay settings.
- Any work on CT and VT circuits: open CT secondaries are dangerous.
Warranty. Repairs carry a warranty of 30 days to 6 months, depending on the item and the repair; the exact term is confirmed before work starts.
FAQ
Protection Relays repair questions
How is the protection relay tested after repair?+
Beyond powering up, the relay is checked with secondary injection so its measuring inputs, protection functions and output contacts are confirmed to work.
More manufacturers
Protection Relays from other manufacturers
- Elobau 462-M51-H21-A
- GE Power Management 489
- Mann + Hummel 79-81-026-715
- Phoenix Contact BAP-SIG-RELAY-4-00-114-229925
- Stucke Elektronik BCG-C0E1-B1A0-C0A0-A1
- Newson Gale Card, tanker earth relay monitoring earth rite II RTR
- Itowa Control card, receiver relay
- Mazak D70EU00936 YM11A
- Panasonic DMUB8D1BL
- Elin DRS-C2A
- Stucke Elektronik ECG-A2K0-B0A0-A5F0-B0
- Lutz EX-RM1
- Larsen & Toubro MCOM ZX80032
- Mitsubishi Electric ME077148
- Seg PCM1-G
- Norvin PWM3021
- Omron PWM9
- Demag Relay, frequency FGB - 2
- Rocon RFI-D3
- Baumüller SAF-001 BM5-O-SAF-001-000-002
- Bitzer SE-I1
- English Electric SKD11BF8002B-M
- GE Multilin SR745-W2-P1-G1-HI-A-R
- Megger SYSTEM SMRT36
- Erl TR241H2
- Osna Electronics WE-77-EX-ERU
Don't see your model?
Engineers on MachineryFix work on far more models than are listed here. Send the make, the model or part number from the nameplate, and the fault, and we'll match an engineer who works on it.
Enter the make and model to continue.
Protection Relays down?
Send the make, model and fault. We'll match an engineer who works on it.