A closed-loop drive that controls the position, velocity and torque of a servo motor using continuous feedback.
01 / Definition
What a Servo Drive is
A servo drive controls a servo motor's position, speed and torque precisely using feedback. The controller or PLC sends a position or speed command; the drive compares it with the actual position reported by the motor's encoder, thousands of times a second, and adjusts the motor current to correct any difference. Three nested loops do this: a current loop inside a speed loop inside a position loop. The result is an axis that moves exactly where and when it is told, which is what CNC machines, packaging machines and pick-and-place systems depend on.
Servo alarms usually point outside the drive. Encoder alarms come from damaged feedback cables and connectors on moving cable chains. Following error alarms mean the axis could not keep up with its command, because of mechanical binding, an overloaded axis or poor tuning. Overcurrent and overload alarms come from crashes, jams or brake problems. Checking the cables and the mechanics before suspecting the drive solves most of them.
Also called
02 / Anatomy
The parts that matter
The components a technician reaches for when this machine stops working.
Power stage
Rectifier, DC bus and IGBT inverter, like a VFD, sized for high peak current.
Control loops
Current, speed and position loops whose gains are set by tuning.
Encoder interface
Reads the motor's absolute or incremental encoder.
Command interface
Pulse-and-direction, analogue, or a motion network such as EtherCAT, Mechatrolink or SSCNET.
Regeneration circuit
Handles energy returned when the axis decelerates.
Safety input
Safe torque off (STO) that removes motor torque safely.
03 / Applications
Where it is used
CNC axes, pick-and-place arms, indexing tables, filling and labelling heads — any motion that must land on an exact position repeatedly.
04 / Failure modes
How it fails
What actually goes wrong on Indian shop floors, and what each fault looks like to the operator.
FM_01
Encoder errors
Damaged cable, a loose connector, noise or a failed encoder.
FM_02
Following error
The axis lags its command: binding, overload or wrong tuning.
FM_03
Overcurrent
A crash, a shorted motor or cable, or a damaged power stage.
FM_04
Overload
Too much continuous torque, often from mechanical drag or a brake not releasing.
FM_05
Regeneration overvoltage
High-inertia axes decelerating without enough regenerative capacity.
05 / Onsite
What our technician checks
A methodical path to root cause, not a scattergun of part swaps.
- 01Read the alarm code and its history
- 02Inspect encoder and power cables along the cable chain, and the connectors
- 03Move the axis by hand (power off) to feel for binding
- 04Check the holding brake releases
- 05Check the load torque and duty against the motor rating
- 06Compare tuning parameters with the commissioning backup
06 / Get it fixed
Related services
The MachineryFix services that cover this equipment.
07 / Questions
Frequently asked questions
What is the difference between a servo drive and a VFD?+
A VFD controls speed, usually without feedback. A servo drive uses encoder feedback to control position and speed precisely, with much faster response.
Why do I get encoder alarms only when the machine moves?+
Usually a cable is breaking or a connector is loose where it flexes in the cable chain.
Can a servo drive be swapped with another of the same model?+
Yes, if the parameters are copied from a backup. Without the parameters, the axis must be set up and tuned again.
What causes following error alarms?+
The axis cannot follow the command: mechanical binding, an overloaded axis, too aggressive an acceleration, or poor tuning.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007