The SINAMICS V90 is Siemens' basic servo drive, used with SIMOTICS S-1FL6 servo motors on packaging, printing, textile and handling machines. Faults show as F codes and alarms as A codes, for example F7801 for motor overcurrent or F30001 for power unit overcurrent.
Below is every fault and alarm in the list in Siemens' V90 operating instructions (edition 04/2014), with the cause and remedy given for each, and each fault's reaction and how it is acknowledged.
01 / Reading codes
Reading and clearing SINAMICS V90 codes
The BOP shows a fault or alarm with its number, for example F7011 or A5000, and marks the first one when several are active. The RDY LED flashes slowly in red. Faults take priority: while a fault is active, alarms are not shown until the fault is acknowledged.
A fault triggers the reaction set for it: OFF1 ramps the motor down, OFF2 lets it coast down, OFF3 stops it quickly as an emergency stop, and NONE takes no action. Each fault page gives the reaction and the acknowledgement type. An alarm takes no action on the motor and acknowledges itself once the cause is gone.
- Remove the cause first. Then acknowledge the fault on the BOP, with the RESET digital input, or in SINAMICS V-ASSISTANT.
- Each fault has its own acknowledgement type: POWER ON (power the drive off and on after removing the cause), IMMEDIATELY (it clears once the cause is removed), or PULSE INHIBIT (it can only be acknowledged with a pulse inhibit).
- If the cause is not removed, the fault can come back after five seconds with no button pressed.
- Alarms acknowledge themselves.
02 / Current and earth faults
Current and earth faults
| Code | Name | Kind |
|---|---|---|
| F7410 | Current controller output limited | Fault · Output phase loss |
| F7801 | Motor overcurrent | Fault · Overcurrent |
| F30001 | Power unit: Overcurrent | Fault · Overcurrent |
| F30015 | Phase failure motor cable | Fault · Output phase loss |
| F30021 | Ground fault | Fault · Earth fault |
| A30031 | Hardware current limiting in phase U | Alarm · Overcurrent |
03 / Voltage and supply
Voltage and supply
| Code | Name | Kind |
|---|---|---|
| F7403 | Lower DC link voltage threshold reached | Fault · DC bus undervoltage |
| F7404 | Upper DC link voltage threshold reached | Fault · DC bus overvoltage |
| F30002 | DC link voltage, overvoltage | Fault · DC bus overvoltage |
| F30003 | DC link voltage, undervoltage | Fault · DC bus undervoltage |
| F30011 | Line phase failure in main circuit | Fault · Input phase loss |
| F30027 | Precharging DC link time monitoring | Fault · DC bus undervoltage |
| A30016 | Load supply switched off | Alarm · DC bus undervoltage |
| A52901 | Braking resistor reaches alarm threshold | Alarm · Braking resistor |
04 / Temperature and overload
Temperature and overload
| Code | Name | Kind |
|---|---|---|
| F7011 | Motor overtemperature | Fault · Motor overload or overtemperature |
| F30004 | Drive heat sink overtemperature | Fault · Drive overtemperature |
| F30005 | Power unit: Overload I2t | Fault · Drive overload |
| F30036 | Internal overtemperature | Fault · Drive overtemperature |
| A1009 | Control module overtemperature | Alarm · Drive overtemperature |
| A5000 | Drive heat sink overtemperature | Alarm · Drive overtemperature |
| A7012 | Motor temperature model 1/3 overtemperature | Alarm · Motor overload or overtemperature |
05 / Motor and load
Motor and load
| Code | Name | Kind |
|---|---|---|
| F7450 | Standstill monitoring has responded | Fault · Motor stall |
| F7452 | Following error too high | Fault · Motor stall |
| F7475 | EPOS: Target position < start of traversing rangeThe target position for relative traversing is outside the traversing range. Correct the target position. | Fault · Overtravel |
| F7476 | EPOS: Target position > end of the traversing rangeThe target position for relative traversing is outside the traversing range. Correct the target position. | Fault · Overtravel |
| F7481 | EPOS: Axis position < software limit switch minus | Fault · Overtravel |
| F7482 | EPOS: Axis position > software limit switch plus | Fault · Overtravel |
| F7491 | STOP cam minus reached | Fault · Overtravel |
| F7492 | STOP cam plus reached | Fault · Overtravel |
| F7900 | Motor blocked/speed controller at its limit | Fault · Motor stall |
| F7901 | Motor overspeedThe maximum permissible speed was exceeded. Check and correct the maximum speed (p1082). | Fault · Load monitoring |
| A7469 | EPOS: Traversing block < target position < software limit switch minus | Alarm · Overtravel |
| A7470 | EPOS: Traversing block > target position > software limit switch plus | Alarm · Overtravel |
| A7473 | EPOS: Beginning of traversing range reachedThe axis reached the traversing range limit. Move away in the positive direction. | Alarm · Overtravel |
| A7474 | EPOS: End of traversing range reachedThe axis reached the traversing range limit. Move away in the negative direction. | Alarm · Overtravel |
| A7477 | EPOS: Target position < software limit switch minus | Alarm · Overtravel |
| A7478 | EPOS: Target position > software limit switch plus | Alarm · Overtravel |
| A7479 | EPOS: Software limit switch minus reached | Alarm · Overtravel |
| A7480 | EPOS: Software limit switch plus reached | Alarm · Overtravel |
06 / Signals and communication
Signals and communication
| Code | Name | Kind |
|---|---|---|
| F1030 | Sign-of-life failure for master controlWith PC master control active, no sign of life arrived within the monitoring time. Contact the Siemens hotline. | Fault · Communication loss |
| F1611 | SI CU: Defect detected | Fault · Safety input |
| F7412 | Commutation angle incorrect (motor model) | Fault · Encoder signal |
| F7430 | Changeover to open-loop torque controlled operation not possible | Fault · Encoder signal |
| F7431 | Changeover to encoderless operation not possible | Fault · Encoder signal |
| F7443 | Reference point coordinate not in the permissible rangeThe reference point coordinate received when adjusting the encoder through connector input p2599 is outside half the encoder range, so it cannot be set as the actual axis position. Set the reference point coordinate below the value given in the fault value (see p2599). For a motor with an absolute encoder, the largest permissible encoder range is (4096 × p29247) / 2. | Fault · Reference position |
| F7453 | Position actual value preprocessing errorAn error occurred while preprocessing the actual position value. Check the encoder used for the actual position value. | Fault · Encoder signal |
| F7458 | EPOS: Reference cam not found | Fault · Reference position |
| F7459 | Zero mark not detected | Fault · Reference position |
| F7460 | EPOS: End of reference cam not found | Fault · Reference position |
| F7599 | Encoder 1: Adjustment not possibleThe maximum encoder value, converted from increments to length units, went beyond the range for showing the actual position (-2147483648 to 2147483647). | Fault · Encoder signal |
| F31100 | Zero mark distance error | Fault · Encoder signal |
| F31110 | Serial communications errorA serial protocol transfer error between the encoder and the evaluation module. Contact the Siemens hotline. | Fault · Encoder signal |
| F31112 | Error bit set in the serial protocolThe encoder sends an error bit through the serial protocol. Contact the Siemens hotline. | Fault · Encoder signal |
| F31117 | Inversion error signals A/B/R | Fault · Encoder signal |
| F31130 | Zero mark and position error from the coarse synchronization | Fault · Encoder signal |
| F31150 | Initialization error | Fault · Encoder signal |
| F52980 | Absolute encoder motor changedThe servo motor with absolute encoder was changed: the motor ID differs from the commissioned one. Acknowledge the fault: the servo motor is then configured automatically. | Fault · Encoder signal |
| F52981 | Absolute encoder motor mismatchedThe connected absolute encoder motor cannot be run: the servo drive does not support its motor ID. Use a suitable absolute encoder motor. | Fault · Encoder signal |
| F52983 | No encoder detected | Fault · Encoder signal |
| F52984 | Incremental encoder motor not configuredCommissioning of the servo motor failed: the incremental encoder motor is connected but could not be commissioned. Configure the motor ID in p29000. | Fault · Encoder signal |
| F52985 | Absolute encoder motor wrong | Fault · Encoder signal |
| F52987 | Absolute encoder replacedThe absolute encoder data is incorrect. Contact the Siemens hotline. | Fault · Encoder signal |
| A1920 | Drive Bus: Receive setpoints after To | Alarm · Communication loss |
| A1932 | Drive Bus clock cycle synchronization missing for DSCDynamic Servo Control (DSC) is selected, but there is no clock synchronisation or clock-synchronous sign of life. Set clock synchronisation in the bus configuration and transfer a clock-synchronous sign of life. | Alarm · Communication loss |
| A7461 | EPOS: Reference point not setA traversing block or direct setpoint started with no reference point set. Reference the system: search for reference, flying referencing, or set the reference point. | Alarm · Reference position |
| A7576 | Encoderless operation due to a fault active | Alarm · Encoder signal |
| A31411 | Absolute encoder signals internal alarmsThe absolute encoder's fault word has alarm bits set. Replace the encoder. | Alarm · Encoder signal |
| A31412 | Error bit set in the serial protocol | Alarm · Encoder signal |
| A52902 | Emergency missingServo on was given while the emergency input (EMGS) was off. Switch on the emergency input (EMGS), then give servo on. | Alarm · Safety input |
07 / Setup, memory and internal
Setup, memory and internal
| Code | Name | Kind |
|---|---|---|
| F1000 | Internal software error | Fault · Internal drive fault |
| F1001 | FloatingPoint exception | Fault · Internal drive fault |
| F1002 | Internal software error | Fault · Internal drive fault |
| F1003 | Acknowledgement delay when accessing the memory | Fault · Internal drive fault |
| F1015 | Internal software error | Fault · Internal drive fault |
| F1018 | Booting has been interrupted several times | Fault · Internal drive fault |
| F7085 | Open-loop/closed-loop control parameters changedControl parameters had to be changed, because other parameters pushed them past their dynamic limits, or because the hardware lacks features they need. No change is needed: the parameters have already been limited correctly. | Fault · Setup |
| F7442 | LR: Multiturn does not match the modulo rangeThe ratio between the multiturn resolution and the modulo range (p29246) is not a whole number, so the adjustment is reset: the actual position cannot be reproduced after a power cycle. Make the ratio a whole number. It is calculated as v = (4096 × p29247 × p29248) / (p29249 × p29246). | Fault · Setup |
| F7490 | Enable signal withdrawn while traversing | Fault · Setup |
| F7493 | LR: Overflow of the value range for position actual value | Fault · Setup |
| F7802 | Infeed or power unit not ready | Fault · Internal drive fault |
| F7815 | Power unit has been changedThe code number of the fitted power unit does not match the saved one. Connect the original power unit and power the Control Unit up again (POWER ON). | Fault · Internal drive fault |
| F7995 | Motor identification failureA motor with an incremental encoder needs pole position identification at the first servo on; if the motor is already turning, for example pushed by an outside force, identification can fail. Stop the motor before switching the servo on. | Fault · Motor identification |
| F30050 | 24 V supply overvoltage | Fault · Internal drive fault |
| F52903 | Fault inconsistence between fault status and fault bufferThe fault status and the fault number buffer do not match. Power the drive off and on. | Fault · Internal drive fault |
| F52904 | Control mode changeThe control mode was changed: the drive must be saved and restarted. Save and restart the drive. | Fault · Setup |
| F52911 | Positive torque limitation value errorOne of the positive torque limit values (P29050) is below 0. Set all the positive torque limit values (P29050) to 0 or more. | Fault · Setup |
| F52912 | Negative torque limitation value errorOne of the negative torque limit values (P29051) is above 0. Set all the negative torque limit values (P29051) to 0 or less. | Fault · Setup |
| F52931 | Gear box limitThe electronic gear ratio (p29012[x] / p29013[x]) is outside the range 0.02 to 200. Set the electronic gear ratio within 0.02 to 200. | Fault · Setup |
| A1019 | Writing to the removable data medium unsuccessfulWriting to the removable data medium failed. Remove and check the data medium, then run the data backup again. | Alarm · Parameter memory |
| A1032 | All parameters must be savedOne drive object's parameters were saved, but there is no backup of all the drive system's parameters yet. The saved object-specific parameters will not load at the next power-up. Save all parameters. | Alarm · Parameter memory |
| A1045 | Configuring data invalidAn error was found in the parameter files saved in non-volatile memory, so some saved values may not have been accepted. Save the parameters with "Copy RAM to ROM" in SINAMICS V-ASSISTANT, or on the BOP. This overwrites the bad files and the alarm goes. | Alarm · Parameter memory |
| A7441 | LR: Save the position offset of the absolute encoder adjustmentThe absolute encoder adjustment changed, and the position offset (p2525) must be saved to keep it. None needed: the alarm disappears once the offset is saved. | Alarm · Setup |
| A7456 | EPOS: Setpoint velocity limitedThe setpoint velocity is above the set maximum velocity, so it is limited. Reduce the setpoint velocity. | Alarm · Setup |
| A7471 | EPOS: Traversing block target position outside the modulo range | Alarm · Setup |
| A7472 | EPOS: Traversing block ABS_POS/ABS_NEG not possibleThe traversing block uses ABS_POS or ABS_NEG positioning without modulo correction activated. Correct the traversing block. | Alarm · Setup |
| A7496 | SON enable missingIn PTI mode, or a compound mode with PTI, the drive is in the servo off state. Enable servo on for the drive. | Alarm · Setup |
| A7585 | P-TRG or CLR activeIn PTI mode, or a compound mode with PTI, the P-TRG or CLR function is active. In PTI mode, deactivate P-TRG or CLR; in a compound mode with PTI, do not switch to other modes. | Alarm · Setup |
| A7965 | Save requiredThe angular commutation offset was redefined but not yet saved. Save it to non-volatile memory to keep the new value; the alarm then disappears. | Alarm · Setup |
| A7971 | Angular commutation offset determination activatedAutomatic determination of the angular commutation offset (encoder adjustment) is activated; it runs at the next power-on command. None needed: the alarm disappears once the determination is done. | Alarm · Motor identification |
| A7991 | Motor data identification activated | Alarm · Motor identification |
| A52900 | Failure during data copying | Alarm · Parameter memory |
| A52932 | PTO max limitThe PTO frequency is above its limit, which the manual gives as 120K with an incremental encoder and 280K with an absolute encoder. Change the PTO ratio. | Alarm · Setup |
Related
Related pages
Source
Siemens, SINAMICS V90, SIMOTICS S-1FL6 Operating Instructions, 04/2014, 6SL3298-0AV60-0BP0, 11 Diagnostics (11.2 List of faults and alarms).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007