The ASDA-B2 is Delta Electronics' general-purpose AC servo drive, paired with ECMA servo motors in ratings from 100 W to 3 kW. It shows alarms as AL codes on its front panel display, such as AL001 for over current or AL009 for excessive position deviation.
Below is every alarm in chapter 9 of Delta's ASDA-B2 user manual, with the causes, the checks and corrective actions Delta lists, and how each alarm is cleared.
01 / Reading codes
Reading and clearing ASDA-B2 codes
The drive's front panel display shows the alarm as ALnnn, for example AL011 for an encoder error. The five most recent alarms are kept in P4-00 (the latest) to P4-04. For AL017, pressing SHIFT shows an E code that points to the parameter or memory area at fault.
This alarm switches the servo off, so the motor is no longer driven until the alarm is cleared. This is a warning: the drive reports it on its WARN output and the servo stays on.
- Remove the cause first. Most alarms clear by turning on the alarm reset input, DI.ARST (assigned to DI5 by default).
- Some alarms clear only after the drive is powered off and on: AL004, AL011, AL024 to AL029, AL031 and AL035. AL003 also needs a power cycle, unless P2-66 bit 2 is set so it clears once the voltage is back to normal.
- AL013 clears by itself once the emergency stop input (DI.EMGS) is off. AL014 and AL015 clear with DI.ARST, by switching the servo off, or by moving the motor back off the limit.
- AL099 clears by setting P2-08 to 30, then to 28, and powering the drive off and on. For AL555 and AL880, do nothing to the drive: Delta's instruction is to send it back to the distributor or contact Delta.
02 / Current and earth faults
Current and earth faults
| Code | Name | Kind |
|---|---|---|
| AL001 | Over current | Alarm · Overcurrent |
| AL031 | Incorrect wiring of the motor power line U, V, W, GNDThe motor's U, V, W are connected wrongly, or the connection has broken. Check the motor's U, V, W connections; wire them correctly as the user manual shows, and make sure the motor is grounded. | Alarm · Output phase loss |
| AL083 | Servo drive outputs excessive current | Alarm · Output short circuit |
03 / Voltage and supply
Voltage and supply
| Code | Name | Kind |
|---|---|---|
| AL002 | Over voltage | Alarm · DC bus overvoltage |
| AL003 | Under voltage | Alarm · DC bus undervoltage |
| AL005 | Regeneration error | Alarm · Braking resistor |
| AL022 | Main circuit power lack phaseThe main circuit power is abnormal. Check whether the R, S, T power cable is loose or not connected; on a single-phase drive the alarm also appears when no power is connected. Make sure power is applied. If it persists, Delta's instruction is to send the drive back to the distributor or contact Delta. | Alarm · Input phase loss |
| AL085 | Regeneration error | Alarm · Braking resistor |
04 / Temperature and overload
Temperature and overload
| Code | Name | Kind |
|---|---|---|
| AL006 | Overload | Alarm · Motor overload or overtemperature |
| AL016 | IGBT overheat | Alarm · Drive overtemperature |
| AL023 | Early warning for overload | Warning · Motor overload or overtemperature |
| AL035 | Encoder temperature exceeds the protective rangeThe encoder temperature is over 120°C. Check whether the ambient temperature is too high or the motor temperature is over 105°C, and reduce the operating temperature. | Alarm · Motor overload or overtemperature |
| AL067 | Encoder temperature warningThe encoder temperature is over 100°C (above the warning level, still within the protective range). Check whether the operating temperature is too high or the motor temperature is over 85°C, and reduce the operating temperature. | Alarm · Motor overload or overtemperature |
05 / Motor and load
Motor and load
06 / Signals and communication
Signals and communication
| Code | Name | Kind |
|---|---|---|
| AL004 | Motor combination error | Alarm · Encoder signal |
| AL011 | Encoder error | Alarm · Encoder signal |
| AL013 | Emergency stopThe emergency stop button is pressed. Check whether the emergency stop button is pressed, and release it. | Alarm · Safety input |
| AL018 | Abnormal signal output | Alarm · Encoder signal |
| AL019 | Serial communication error | Alarm · Communication loss |
| AL020 | Serial communication time out | Warning · Communication loss |
| AL024 | Encoder initial magnetic field error | Alarm · Encoder signal |
| AL025 | The internal of the encoder is in error | Alarm · Encoder signal |
| AL026 | Unreliable internal data of the encoder | Alarm · Encoder signal |
| AL027 | The internal of the encoder is in errorThe encoder's internal reset is in error. Check the servo is properly grounded. Delta's corrective action is to connect the UVW connector's green lead to the servo drive's heat sink. | Alarm · Encoder signal |
| AL028 | The internal of the encoder is in errorThe encoder's U, V, W signals are in error. Check the servo is properly grounded. Delta's corrective action is to connect the UVW connector's green lead to the servo drive's heat sink. | Alarm · Encoder signal |
| AL029 | The internal of the encoder is in errorThe encoder's internal address is in error. Check the servo is properly grounded. Delta's corrective action is to connect the UVW connector's green lead to the servo drive's heat sink. | Alarm · Encoder signal |
| AL048 | Excessive encoder output error | Alarm · Encoder signal |
07 / Setup, memory and internal
Setup, memory and internal
| Code | Name | Kind |
|---|---|---|
| AL008 | Abnormal pulse commandThe pulse command frequency is higher than the rated input frequency. Check the input frequency with a scope, and set the input pulse frequency correctly. | Alarm · Setup |
| AL012 | Adjustment error | Alarm · Internal drive fault |
| AL017 | Abnormal EEPROM | Alarm · Parameter memory |
| AL099 | DSP firmware upgrade | Warning · Parameter memory |
| AL555 | System failureA DSP processing error. Do nothing to the drive: Delta's instruction is to send it back to the distributor or contact Delta. | Alarm · Internal drive fault |
| AL880 | System failureA DSP processing error. Do nothing to the drive: Delta's instruction is to send it back to the distributor or contact Delta. | Alarm · Internal drive fault |
Related
Related pages
Source
Delta Electronics, ASDA-B2 Standard AC Servo Drive User Manual, Revision May 2018, DELTA_IA-ASDA_B2_UM_EN_20180509, Chapter 9, Troubleshooting (9.1 to 9.3).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Delta and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007