MachineryFix

Servo drive · 37 codes

Delta ASDA-B2 alarm codes

The ASDA-B2 is Delta Electronics' general-purpose AC servo drive, paired with ECMA servo motors in ratings from 100 W to 3 kW. It shows alarms as AL codes on its front panel display, such as AL001 for over current or AL009 for excessive position deviation.

Below is every alarm in chapter 9 of Delta's ASDA-B2 user manual, with the causes, the checks and corrective actions Delta lists, and how each alarm is cleared.

01 / Reading codes

Reading and clearing ASDA-B2 codes

The drive's front panel display shows the alarm as ALnnn, for example AL011 for an encoder error. The five most recent alarms are kept in P4-00 (the latest) to P4-04. For AL017, pressing SHIFT shows an E code that points to the parameter or memory area at fault.

This alarm switches the servo off, so the motor is no longer driven until the alarm is cleared. This is a warning: the drive reports it on its WARN output and the servo stays on.

  • Remove the cause first. Most alarms clear by turning on the alarm reset input, DI.ARST (assigned to DI5 by default).
  • Some alarms clear only after the drive is powered off and on: AL004, AL011, AL024 to AL029, AL031 and AL035. AL003 also needs a power cycle, unless P2-66 bit 2 is set so it clears once the voltage is back to normal.
  • AL013 clears by itself once the emergency stop input (DI.EMGS) is off. AL014 and AL015 clear with DI.ARST, by switching the servo off, or by moving the motor back off the limit.
  • AL099 clears by setting P2-08 to 30, then to 28, and powering the drive off and on. For AL555 and AL880, do nothing to the drive: Delta's instruction is to send it back to the distributor or contact Delta.

02 / Current and earth faults

Current and earth faults

CodeNameKind
AL001Over currentAlarm · Overcurrent
AL031Incorrect wiring of the motor power line U, V, W, GNDThe motor's U, V, W are connected wrongly, or the connection has broken. Check the motor's U, V, W connections; wire them correctly as the user manual shows, and make sure the motor is grounded.Alarm · Output phase loss
AL083Servo drive outputs excessive currentAlarm · Output short circuit

03 / Voltage and supply

Voltage and supply

CodeNameKind
AL002Over voltageAlarm · DC bus overvoltage
AL003Under voltageAlarm · DC bus undervoltage
AL005Regeneration errorAlarm · Braking resistor
AL022Main circuit power lack phaseThe main circuit power is abnormal. Check whether the R, S, T power cable is loose or not connected; on a single-phase drive the alarm also appears when no power is connected. Make sure power is applied. If it persists, Delta's instruction is to send the drive back to the distributor or contact Delta.Alarm · Input phase loss
AL085Regeneration errorAlarm · Braking resistor

04 / Temperature and overload

Temperature and overload

CodeNameKind
AL006OverloadAlarm · Motor overload or overtemperature
AL016IGBT overheatAlarm · Drive overtemperature
AL023Early warning for overloadWarning · Motor overload or overtemperature
AL035Encoder temperature exceeds the protective rangeThe encoder temperature is over 120°C. Check whether the ambient temperature is too high or the motor temperature is over 105°C, and reduce the operating temperature.Alarm · Motor overload or overtemperature
AL067Encoder temperature warningThe encoder temperature is over 100°C (above the warning level, still within the protective range). Check whether the operating temperature is too high or the motor temperature is over 85°C, and reduce the operating temperature.Alarm · Motor overload or overtemperature

05 / Motor and load

Motor and load

CodeNameKind
AL007Over speedAlarm · Load monitoring
AL009Excessive deviation of position commandAlarm · Motor stall
AL014Reverse limit errorWarning · Overtravel
AL015Forward limit errorWarning · Overtravel
AL030Motor crash errorAlarm · Load monitoring

06 / Signals and communication

Signals and communication

CodeNameKind
AL004Motor combination errorAlarm · Encoder signal
AL011Encoder errorAlarm · Encoder signal
AL013Emergency stopThe emergency stop button is pressed. Check whether the emergency stop button is pressed, and release it.Alarm · Safety input
AL018Abnormal signal outputAlarm · Encoder signal
AL019Serial communication errorAlarm · Communication loss
AL020Serial communication time outWarning · Communication loss
AL024Encoder initial magnetic field errorAlarm · Encoder signal
AL025The internal of the encoder is in errorAlarm · Encoder signal
AL026Unreliable internal data of the encoderAlarm · Encoder signal
AL027The internal of the encoder is in errorThe encoder's internal reset is in error. Check the servo is properly grounded. Delta's corrective action is to connect the UVW connector's green lead to the servo drive's heat sink.Alarm · Encoder signal
AL028The internal of the encoder is in errorThe encoder's U, V, W signals are in error. Check the servo is properly grounded. Delta's corrective action is to connect the UVW connector's green lead to the servo drive's heat sink.Alarm · Encoder signal
AL029The internal of the encoder is in errorThe encoder's internal address is in error. Check the servo is properly grounded. Delta's corrective action is to connect the UVW connector's green lead to the servo drive's heat sink.Alarm · Encoder signal
AL048Excessive encoder output errorAlarm · Encoder signal

07 / Setup, memory and internal

Setup, memory and internal

CodeNameKind
AL008Abnormal pulse commandThe pulse command frequency is higher than the rated input frequency. Check the input frequency with a scope, and set the input pulse frequency correctly.Alarm · Setup
AL012Adjustment errorAlarm · Internal drive fault
AL017Abnormal EEPROMAlarm · Parameter memory
AL099DSP firmware upgradeWarning · Parameter memory
AL555System failureA DSP processing error. Do nothing to the drive: Delta's instruction is to send it back to the distributor or contact Delta.Alarm · Internal drive fault
AL880System failureA DSP processing error. Do nothing to the drive: Delta's instruction is to send it back to the distributor or contact Delta.Alarm · Internal drive fault

Related

Related pages

Source

Delta Electronics, ASDA-B2 Standard AC Servo Drive User Manual, Revision May 2018, DELTA_IA-ASDA_B2_UM_EN_20180509, Chapter 9, Troubleshooting (9.1 to 9.3).

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Delta and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

ASDA-B2 fault you can't clear?

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.