MachineryFix

Breakdown & Maintenance

Condition Monitoring & IoT

Sensors and drive data on the machines that justify it, designed per plant after a survey. Read-only, with alerts to your own maintenance staff.

  • Phone answered 24/7

    Call at any hour to report a breakdown.

  • Verified, experienced technicians

    Identity checked before a technician is sent to your plant.

Breakdown & Maintenance

What we do

Condition monitoring means leaving sensors on a machine so its temperature, vibration, current or drive status is recorded continuously instead of during a visit. It suits machines that are critical, hard to reach safely while running, or spread across several plants where nobody can walk round with an instrument every week.

MachineryFix designs and installs monitoring per plant, on request. There is no standard box to buy: the first step is a survey of the machines and what data they can already give. Many drives and PLCs report current, temperature, fault history and running hours over their own network port, which is often enough without adding a single sensor. Where sensors are needed, they are chosen for that machine.

Most machines do not need permanent monitoring. Periodic readings with portable instruments, as in a preventive and predictive maintenance schedule, cover them at lower cost. The survey says plainly which machines justify sensors and which do not.

Scope

What's covered

  • A survey of which machines are worth monitoring, and which are not
  • Drive data read out over the drive's own network port where it has one
  • Vibration and temperature sensors on motors, gearboxes, pumps and fans
  • Panel temperature and supply-quality logging
  • Alerts to your maintenance staff when a reading leaves its normal range
  • Read-only by design: the monitoring never sends commands to the machine

Failure modes

How condition monitoring & iot faults usually show up

  • Bearings and rotating parts

    Wear shows as rising vibration and temperature well before a seizure. This is where continuous readings give the longest warning.

  • Drives running hot

    Heatsink temperature, fan condition and DC bus behaviour drift before a drive fails. Most current drives already measure these and can report them.

  • Panels in summer

    Panel temperature climbing through April to June points to blocked filters or failed fans before components start tripping.

  • Supply problems

    Voltage dips and phase imbalance cause nuisance trips and early motor failures. A log of supply events separates a supply problem from an equipment one.

First checks

What you can check first, and what needs a specialist

Safe for a plant electrician

  • Check which of your drives and PLCs already have an unused network port.
  • Look at each drive's own fault history and running hours from its keypad.
  • Keep a manual log of temperatures and trips for a month; it shows which machines are worth monitoring.

Needs lockout or a specialist

  • Fitting sensors and current transformers inside panels or on running machines.
  • Connecting to a drive or PLC network without disturbing the control system.
  • Setting alert limits, which needs a baseline and knowledge of the machine.

Local conditions

In Hyderabad plants

Heat is the main reason to monitor panels and drives in Hyderabad: readings through April to June show which enclosures need better cooling before parts fail.

For groups with plants in several estates or cities, the design is done plant by plant, since network access and drive makes differ at each site.

Send the machine list and locations first. A plant outside Hyderabad can be surveyed from the drive and PLC models before anyone travels.

Before the visit

What to have ready before the technician arrives

  1. 01List the machines you are considering, and why each one matters.
  2. 02Note the drive and PLC makes and models, and whether they have a network port.
  3. 03Say who should receive alerts, and how: phone, email or a screen in the maintenance room.
  4. 04Involve whoever looks after the plant network early, since monitoring must sit apart from the control network.

Verification

How the repair is checked before handover

  • Each sensor and data point is checked against a portable instrument at commissioning.
  • Normal ranges are set from the machine's own baseline, not a generic table.
  • Alerts are tested end to end, to the person who is meant to receive them.
  • The system is confirmed to be read-only: it cannot change a setting or start a machine.

Parts

Boards and parts commonly involved

  • Vibration and temperature sensors
  • Current transformers and power meters
  • Gateways that read drive and PLC data
  • Panel temperature and humidity sensors
  • Cabling, enclosures and power supplies for the above

Job card

What the job card records

  • Machines surveyed and which were selected
  • Data points read from drives and PLCs, and sensors fitted
  • Baselines recorded and alert limits set
  • Who receives alerts and by what route
  • Network arrangement and what the system can and cannot access

Questions

Condition Monitoring & IoT: common questions

Which machines are worth monitoring continuously?+

Ones whose failure stops production, that give warning before failing (bearings, motors, drives running hot), and that are costly to check by hand: hard to reach, running unattended, or one of many identical drives across sites. A robust machine that is easy to inspect rarely justifies permanent sensors.

Can you monitor the drives across several of our plants?+

Yes, where the drives can report their status over a network port, which most current ones can. Each plant's drives are read locally and the readings are brought together so one team can see which drive is running hot, tripping repeatedly or reporting a fault. The design depends on the drive makes and each site's network, so it starts with a survey.

Is connecting plant equipment to a network a security risk?+

It can be, and it should be treated seriously. Monitoring should be one-directional wherever possible, reading data out and never accepting control commands in, and kept separate from your control network. A monitoring system that can write to a PLC is a real risk; one that only reads is a much smaller one.

Do you sell a monitoring product or dashboard?+

No. This is an engineering service: the sensors, gateways and display are selected per plant from what suits the machines and what your team will actually use. You are told what each part is and what it costs before anything is ordered.

What happens when an alert comes in?+

Your maintenance staff get it first, by the route agreed at commissioning. Limits are set with you so that the alerts reaching people are ones worth acting on: some mean plan a bearing change at the next stop, a few mean stop the machine now. If you want a technician to attend, the readings leading up to the alert go with the request.

How is this different from predictive maintenance visits?+

Predictive maintenance visits take readings with portable instruments at intervals. Condition monitoring leaves the measurement in place, so changes between visits are seen. Most plants use visits for most machines and monitoring for a few critical ones.

Does monitoring need internet access from the plant?+

Only if you want to see readings off site. A system that alerts people inside the plant can run on a local network alone. If off-site access is needed it is set up as outbound-only from the monitoring side.

Guides

Related guides

Related

Related services

Written & reviewed by MachineryFix

Last reviewed — questions? Call +91 70133 33007

Need condition monitoring & iot?

Send the machine and the fault code. We'll match a technician who works on that equipment.