MachineryFix

AC drive (VFD) · 51 codes

Hitachi WJ200 fault codes

The WJ200 is Hitachi's compact AC inverter, built for single-phase 200 V, three-phase 200 V and three-phase 400 V supplies. When it trips, the display shows an error code in the form E xx, such as E01 for over-current or E07 for over-voltage.

Below is every error code in the table in Hitachi's WJ200 instruction manual, with the cause Hitachi gives for each. The manual lists causes only; the general checks for each kind of fault are on this site's category guides.

01 / Reading codes

Reading and clearing WJ200 codes

The display shows the error automatically when a fault trips the inverter, in the form E xx. The inverter records each trip in its trip history; setting B084 to 00 clears the trip history and keeps the other settings.

A trip switches the inverter's output off, the way a circuit breaker trips on over-current, and the error code stays on the display until it is reset.

  • Remove the cause, then press the STOP/RESET key or switch on an input terminal set as RS (reset).
  • Reset is not accepted for 10 seconds after a trip.
  • For E08, E14 and E30, reset by RS or STOP/RESET is not accepted: switch the power off and on. If the same error comes back, initialise the inverter.

02 / Current and earth faults

Current and earth faults

CodeNameKind
E01Over-current event while at constant speedThe inverter output was short-circuited, or the motor shaft is locked or heavily loaded: the excessive current makes the inverter switch its output off. Fault · Overcurrent
E02Over-current event during decelerationThe inverter output was short-circuited, or the motor shaft is locked or heavily loaded: the excessive current makes the inverter switch its output off. Fault · Overcurrent
E03Over-current event during accelerationThe inverter output was short-circuited, or the motor shaft is locked or heavily loaded: the excessive current makes the inverter switch its output off. Fault · Overcurrent
E04Over-current event during other conditionsThe inverter output was short-circuited, or the motor shaft is locked or heavily loaded: the excessive current makes the inverter switch its output off. Fault · Overcurrent
E14Ground faultA ground fault between the inverter output and the motor was detected during the power-up test. The feature protects the inverter, not people. Fault · Earth fault

03 / Voltage and supply

Voltage and supply

CodeNameKind
E06Braking resistor overload protectionThe braking resistor (BRD) operation rate went above the setting in b090, so the inverter switched its output off. Fault · Braking resistor
E07Over-voltage protectionThe DC bus voltage went above its threshold, from energy regenerated by the motor. Fault · DC bus overvoltage
E09Under-voltage errorThe internal DC bus voltage fell below its threshold, causing a control circuit fault. Low voltage can also overheat the motor or reduce its torque. Fault · DC bus undervoltage
E15Input over-voltageThe input voltage was too high when tested after the inverter had been in Stop mode for 100 seconds. Once the condition clears, the inverter can run again. Fault · DC bus overvoltage

04 / Temperature and overload

Temperature and overload

CodeNameKind
E05Overload protectionThe electronic thermal function detected a motor overload, so the inverter tripped and switched its output off. Fault · Motor overload or overtemperature
E21Inverter thermal tripThe inverter's internal temperature went above its threshold: the thermal sensor in the inverter module detected the power devices running too hot. Fault · Drive overtemperature
E35ThermistorA thermistor connected to terminals [5] and [L] sensed too high a temperature. Fault · Motor overload or overtemperature
E38Low-speed overload protectionAn overload while the motor was running at very low speed. Fault · Drive overload

05 / Motor and load

Motor and load

CodeNameKind
E81Excessive speedThe motor speed reached the maximum frequency (A004) times the over-speed detection level (P026), or more. Fault · Load monitoring
E83Positioning range errorThe current position went beyond the position range (P072 to P073). Fault · Overtravel

06 / Signals and communication

Signals and communication

CodeNameKind
E12External tripAn input terminal set as EXT (external trip) received a signal. Fault · External fault
E36Braking errorWith brake control enabled (b120 = 01), the brake confirmation signal did not arrive within the wait time (b124) after the brake release signal was output. Fault · External fault
E37Safe StopThe safe stop signal was given. Fault · Safety input
E40Operator connectionThe connection between the inverter and the operator keypad failed. Fault · Communication loss
E41Modbus communication errorWith "trip" selected for a communication error (C076 = 00), a communication timeout occurred. Fault · Communication loss
E50EzSQ user trip 0A user-defined trip (0) in the EzSQ program. Fault · External fault
E51EzSQ user trip 1A user-defined trip (1) in the EzSQ program. Fault · External fault
E52EzSQ user trip 2A user-defined trip (2) in the EzSQ program. Fault · External fault
E53EzSQ user trip 3A user-defined trip (3) in the EzSQ program. Fault · External fault
E54EzSQ user trip 4A user-defined trip (4) in the EzSQ program. Fault · External fault
E55EzSQ user trip 5A user-defined trip (5) in the EzSQ program. Fault · External fault
E56EzSQ user trip 6A user-defined trip (6) in the EzSQ program. Fault · External fault
E57EzSQ user trip 7A user-defined trip (7) in the EzSQ program. Fault · External fault
E58EzSQ user trip 8A user-defined trip (8) in the EzSQ program. Fault · External fault
E59EzSQ user trip 9A user-defined trip (9) in the EzSQ program. Fault · External fault
E60Option error (DeviceNet communications error)A Bus-Off disconnection or a timeout occurred while running on DeviceNet commands. How the inverter trips is set in P045 and P048. Fault · Communication loss
E61Option error (duplicated MAC ID)Two or more devices with the same MAC ID were found on the same network. Fault · Communication loss
E62Option error (external trip)The Force Fault/Trip bit (attribute 17, instance 1 of the Control Supervisory object) was set to 1. Fault · External fault
E69Option error (inverter communication error)A timeout in communication between the inverter and the DeviceNet option board. Fault · Communication loss
E80Encoder disconnectionThe encoder wiring is disconnected, an encoder connection error was found, the encoder failed, or the encoder does not support line driver output. Fault · Encoder signal

07 / Setup, memory and internal

Setup, memory and internal

CodeNameKind
E08EEPROM errorThe built-in EEPROM memory has a problem, from electrical noise or excessive temperature. Fault · Parameter memory
E10Current detection errorAn error in the inverter's internal current detection system. Fault · Internal drive fault
E11CPU errorThe built-in CPU malfunctioned. Fault · Internal drive fault
E13USPUnattended Start Protection (USP) is on, and power was applied while a Run signal was present. The inverter does not go into Run until the error is cleared. Fault · Setup
E22CPU communication errorCommunication between the inverter's two CPUs failed. Fault · Internal drive fault
E25Main circuit errorThe inverter could not confirm the power supply was established, because of a malfunction from electrical noise or damage to a main circuit element. Fault · Internal drive fault
E30Driver errorAn internal error in the safety protection circuit between the CPU and the main driver unit, possibly from excessive electrical noise. The inverter switched off the IGBT module output. Fault · Internal drive fault
E43EzSQ invalid instructionThe program stored in the inverter's memory is corrupted, or the PRG terminal was switched on with no program downloaded. Fault · Setup
E44EzSQ nesting count errorSubroutines, if statements or for-next loops are nested more than eight levels deep. Fault · Setup
E45EzSQ instruction errorThe inverter found a command it cannot execute. Fault · Setup
E63Option errorThe inverter found an error in the option board in the option slot. The option board's own manual gives the details. Fault · Internal drive fault
E64Option errorThe inverter found an error in the option board in the option slot. The option board's own manual gives the details. Fault · Internal drive fault
E65Option errorThe inverter found an error in the option board in the option slot. The option board's own manual gives the details. Fault · Internal drive fault
E66Option errorThe inverter found an error in the option board in the option slot. The option board's own manual gives the details. Fault · Internal drive fault
E67Option errorThe inverter found an error in the option board in the option slot. The option board's own manual gives the details. Fault · Internal drive fault
E68Option errorThe inverter found an error in the option board in the option slot. The option board's own manual gives the details. Fault · Internal drive fault

Related

Related pages

Source

Hitachi Industrial Equipment Systems, WJ200 Series Inverter Instruction Manual, May 2010, NT325X, Chapter 6, Monitoring Trip Events, History, & Conditions (Error Codes).

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Hitachi and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007