MachineryFix

AC drive (VFD) · 184 codes

Yaskawa GA500 fault codes

The GA500 is Yaskawa's versatile compact AC drive, covering 200 V single-phase input up to 5 HP, 200 V three-phase up to 30 HP and 400 V three-phase up to 40 HP. It runs induction, permanent magnet and synchronous reluctance motors, and takes an LED or Bluetooth LCD keypad.

GA500 codes appear on the keypad as short letter codes, such as oC, ov, GF, oL1 or CPF06, and most are shared with Yaskawa's A1000 and V1000. Below is every fault, minor fault and alarm, parameter setting error (oPE) and Auto-Tuning error (End, Er) in the technical reference's troubleshooting chapter, with the causes and solutions Yaskawa gives.

01 / Reading codes

Reading and clearing GA500 codes

The keypad shows the code. For a fault, ALM/ERR stays lit; for a minor fault or alarm it flashes. Several codes, such as ov, CE, oH and the external faults EF1 to EF7, can appear as either, so note which.

A fault shuts off the drive's output and the motor coasts to a stop (some faults let you choose the stopping method). ALM/ERR stays lit, a terminal set to H2-01 to H2-03 = E activates, and the drive will not run until the fault is reset. A minor fault or alarm leaves the drive running the motor (some let you choose a stopping method) while ALM/ERR flashes. A minor fault activates a terminal set to H2-01 to H2-03 = 10; an alarm gives no signal. No fault reset is needed.

  • Remove the cause, then reset in one of three ways: the reset key on the keypad while the code is shown, a multi-function input set to H1-xx = 14 (terminal S4 by default), or switching off the main circuit power and switching it back on once the keypad display has gone out.
  • A fault will not reset while a run command is active from the terminals or a communication option; the keypad shows CrST until the run command is removed.
  • oL1 resets only once monitor U4-16 (Motor oL1 Level) is below 100.

02 / Current and earth faults

Current and earth faults

CodeNameKind
GFGround FaultFault · Earth fault
LFOutput Phase LossFault · Output phase loss
LF2Output Current ImbalanceFault · Output phase loss
oCOvercurrentFault · Overcurrent
oC2Overcurrent2In OLV/PM, AOLV/PM or EZOLV (A1-02 = 5, 6 or 8), the output current went above L8-27 (Overcurrent Detection Gain). Correct L8-27.Fault · Overcurrent
SCShort Circuit/IGBT FailureFault · Output short circuit
HCAHigh Current AlarmAlarm · Overcurrent

03 / Voltage and supply

Voltage and supply

CodeNameKind
boLBraking Transistor Overload FaultFault · Braking resistor
oL7High Slip Braking OverloadFault · Braking resistor
ovOvervoltageFault · DC bus overvoltage
PFInput Phase LossFault · Input phase loss
rFBraking Resistor FaultFault · Braking resistor
rHBraking Resistor OverheatFault · Braking resistor
rrDynamic Braking Transistor FaultThe drive's control circuit is damaged, or its internal braking transistor has failed. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Braking resistor
Uv1DC Bus UndervoltageFault · DC bus undervoltage
Uv2Control Power UndervoltageFault · DC bus undervoltage
EP24vExternal Power 24V SupplyThe main circuit supply voltage fell, and the 24 V supply is powering the drive. Examine the main circuit supply and switch it on to run the drive.Alarm · DC bus undervoltage
L24vLoss of External Power 24 SupplyThe backup 24 V supply voltage fell while the main circuit supply is working. Examine the external 24 V supply and its wiring, and repair problems.Alarm · DC bus undervoltage
UvDC Bus UndervoltageAlarm · DC bus undervoltage

04 / Temperature and overload

Temperature and overload

CodeNameKind
oHHeatsink OverheatFault · Drive overtemperature
oH1Heatsink OverheatFault · Drive overtemperature
oH3Motor Overheat (PTC Input)Fault · Motor overload or overtemperature
oH4Motor Overheat Fault (PTC Input)Fault · Motor overload or overtemperature
oL1Motor OverloadFault · Motor overload or overtemperature
oL2Drive OverloadFault · Drive overload
LT-1Cooling Fan Maintenance TimeThe cooling fan is at 90% of its expected life. Replace the cooling fan and set o4-03 = 0 to reset its operation time.Alarm · Cooling fan
oH2External Overheat (H1-XX=B)An external device sent an overheat alarm through an input set to H1-xx = B. Find the device that sent the alarm, remove the cause, and clear the input on S1 to S7.Alarm · Drive overtemperature

05 / Motor and load

Motor and load

CodeNameKind
CP1Comparator 1 Limit FaultThe monitor value selected in H2-20 was within the range of H2-21 (lower limit) and H2-22 (upper limit). Examine the monitor value and remove the cause.Fault · Process limit
CP2Comparator 2 Limit FaultThe monitor value selected in H2-26 was outside the range of H2-27 (lower limit) and H2-28 (upper limit). Examine the monitor value and remove the cause.Fault · Process limit
FbHExcessive PID FeedbackFault · Process limit
FbLPID Feedback LossFault · Process limit
LSoLow Speed Motor Step-OutFault · Motor stall
oL3Overtorque Detection 1Fault · Load monitoring
oL4Overtorque Detection 2Fault · Load monitoring
oL5Mechanical Weakening Detection 1The drive detected overtorque under the mechanical weakening conditions set in L6-08. Do a deterioration diagnosis on the machine.Fault · Load monitoring
STPoMotor Step-Out DetectedFault · Motor stall
UL3Undertorque Detection 1Fault · Load monitoring
UL4Undertorque Detection 2Fault · Load monitoring
UL5Mechanical Weakening Detection 2The drive detected undertorque under the mechanical weakening conditions set in L6-08. Examine the machine for deterioration.Fault · Load monitoring

06 / Signals and communication

Signals and communication

CodeNameKind
bCEBluetooth Communication FaultFault · Communication loss
bUSOption Communication ErrorFault · Communication loss
CEModbus Communication ErrorFault · Communication loss
dEvSpeed DeviationFault · Encoder signal
dWF2DriveWorksEZ Fault 2A fault in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause.Fault · External fault
dWF3DriveWorksEZ Fault 3A fault in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause.Fault · External fault
dWFLDriveWorksEZ FaultA fault in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause.Fault · External fault
E5MECHATROLINK Watchdog Timer ErrThe drive detected a watchdog circuit exception while receiving data from the controller. Check the MECHATROLINK cable connection; if it recurs, check the wiring and reduce interference following the MECHATROLINK-II or -III installation manuals.Fault · Communication loss
EF0Option Card External FaultFault · External fault
EF1External Fault (Terminal S1)Fault · External fault
EF2External Fault (Terminal S2)Fault · External fault
EF3External Fault (Terminal S3)Fault · External fault
EF4External Fault (Terminal S4)Fault · External fault
EF5External Fault (Terminal S5)Fault · External fault
EF6External Fault (Terminal S6)Fault · External fault
EF7External Fault (Terminal S7)Fault · External fault
oFA00Option Not Compatible with PortThe option on connector CN5 is not compatible. Connect a compatible option.Fault · Communication loss
oFA01Option Fault/Connection ErrorThe option card on CN5 was changed during operation. De-energize the drive and connect the option card correctly, following its manual.Fault · Communication loss
oFA03Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA04Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA05Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA06Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA10Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA11Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA12Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA13Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA14Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA15Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA16Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA17Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA30Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA31Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA32Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA33Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA34Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA35Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA36Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA37Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA38Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA39Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA40Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA41Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA42Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oFA43Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card.Fault · Communication loss
oPrKeypad Connection FaultFault · Communication loss
oSOverspeedFault · Encoder signal
PE1PLC FaultsThe communication option detected a fault. See the communication option card's manual.Fault · Communication loss
PE2PLC FaultsThe communication option detected a fault. See the communication option card's manual.Fault · Communication loss
PGoEncoder (PG) Feedback LossFault · Encoder signal
SCFSafety Circuit FaultThe safety circuit is broken. Replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Safety input
AErStation Address Setting ErrorAlarm · Communication loss
bbBaseblockAn external baseblock command on input S1 to S7 stopped the drive's output. Check the sequence and timing of the baseblock input.Alarm · External fault
CALLSerial Comm Transmission ErrorAlarm · Communication loss
CyCMECHATROLINK CommCycleSettingErrThe controller's communication cycle is outside the MECHATROLINK option's permitted range. Set the controller's communication cycle within the option's range.Alarm · Communication loss
dWA2DriveWorksEZ Alarm 2An error in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause.Alarm · External fault
dWA3DriveWorksEZ Alarm 3An error in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause.Alarm · External fault
dWALDriveWorksEZ AlarmAn error in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause.Alarm · External fault
PASSModbus Communication TestThe MEMOBUS/Modbus communication test completed. PASS clears once test mode is ended.Alarm · Communication loss
SEModbus Test Mode ErrorMEMOBUS/Modbus self-diagnostics (H1-xx = 67) was run while the drive was running. Stop the drive, then run the self-diagnostics.Alarm · Communication loss
SToFSafe Torque OFF HardwareAlarm · Safety input

07 / Setup, memory and internal

Setup, memory and internal

CodeNameKind
bATKeypad Battery Low VoltageThe keypad battery voltage is low. Replace the keypad battery.Fault · Internal drive fault
CFControl FaultFault · Setup
CoFCurrent Offset FaultFault · Internal drive fault
CPF00Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF01Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF02Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF03Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF06Control Circuit Error (EEPROM memory Data Error)Fault · Parameter memory
CPF08Terminal Board Connection ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF11Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF12Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF13Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF14Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF16Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF17Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF18Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF19Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF20Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF21Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF22Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF23Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF24Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
CPF25Terminal Board not ConnectedThe terminal board is not connected to the drive correctly. De-energize the drive, connect the terminal board correctly, and re-energize.Fault · Internal drive fault
CPF38EEPROM Memory Data ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board).Fault · Internal drive fault
dCE1Communication Error1A temporary drive hardware problem caused by noise. Remove the source of the noise.Fault · Internal drive fault
dCE2Communication Error2A temporary drive hardware problem caused by noise. Remove the source of the noise.Fault · Internal drive fault
dv7Polarity Judge TimeoutFault · Motor identification
dWF1EEPROM Memory DWEZ Data ErrorFault · Parameter memory
ErrEEPROM Write ErrorFault · Parameter memory
nSENode Setup ErrorThe Node Setup input (H1-xx = 47, CANopen) was activated during run, or a run command came while Node Setup was active. Stop the drive while Node Setup is in use.Fault · Setup
SErSpeed Search Retries ExceededFault · Automatic restart limit
TiMKeypad Time Not SetThe keypad has a battery, but the date and time are not set. Set the date and time on the keypad.Fault · Setup
Uv3Soft Charge Answerback FaultFault · Internal drive fault
bUSyBusyAlarm · Setup
CrSTRemove RUN Command to ResetA fault reset command arrived while a run command was active. Turn off the run command, then de-energize and re-energize the drive.Alarm · Setup
CyPoCycle Power to Accept ChangesF6-15 = 1 (reload now) was set, but the drive has not updated the communication option parameters. Re-energize the drive.Alarm · Setup
dnEDrive DisabledA terminal set to H1-xx = 6A (Drive Enable) turned off. Check the operation sequence.Alarm · Setup
EFFWD/REV Run Command Input ErrorForward and reverse commands were both input for longer than 0.5 s. The motor ramps to stop. Check the forward and reverse command sequence and correct it.Alarm · Setup
LoGLog Com ErrorAlarm · Parameter memory
LT-2Capacitor Maintenance TimeThe main and control circuit capacitors are at 90% of expected life. Replace the control board or the drive (contact Yaskawa about replacing the control board).Alarm · Internal drive fault
LT-3SoftChargeBypassRelay MainteTimeThe soft charge bypass relay is at 90% of its expected life. Replace the control board or the drive (contact Yaskawa about replacing the control board).Alarm · Internal drive fault
LT-4IGBT Maintenance Time (50%)The IGBTs are at 50% of expected life. Check the load, carrier frequency and output frequency.Alarm · Internal drive fault
ovErToo Many Parameters ChangedMore than 150 parameters were changed (fewer if some have dependencies). Return parameters that do not affect operation to their defaults.Alarm · Setup
rUnMotor Switch during RunMotor 2 Selection (H1-xx = 16) was input during run. Switch motors only while the drive is stopped.Alarm · Setup
TrPCIGBT Maintenance Time (90%)The IGBTs are at 90% of expected life. Replace the IGBT or the drive.Alarm · Internal drive fault
oPE01Drive Capacity Setting Erroro2-04 (Drive Model) does not match the drive. Set o2-04 correctly.Fault · Setup
oPE02Parameter Range Setting ErrorFault · Setup
oPE03Multi-Function Input Setting ErrFault · Setup
oPE05Run Cmd/Freq Ref Source Sel ErrFault · Setup
oPE07Analog Input Selection ErrorFault · Setup
oPE08Parameter Selection ErrorFault · Setup
oPE09PID Control Selection FaultFault · Setup
oPE10V/f Data Setting ErrorThe V/f pattern does not follow E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04 (E3 parameters for motor 2). Correct the V/f parameters to meet the rule.Fault · Setup
oPE11Carrier Frequency Setting ErrorFault · Setup
oPE13Pulse Monitor Selection ErrorH6-07 = 0 while H6-06 is not 101, 102, 105 or 116. Set H6-06 correctly.Fault · Setup
oPE16Energy Saving Constants ErrorThe energy saving parameters are outside their ranges. Set the E5 parameters from the motor nameplate.Fault · Setup
oPE33Digital Output Selection ErrorFault · Setup
End1Excessive Rated Voltage SettingFault · Motor identification
End2Iron Core Saturation CoefficientFault · Motor identification
End3Rated Current Setting AlarmThe rated current entered is incorrect. Tune again with the rated current from the motor nameplate.Fault · Motor identification
End4Adjusted Slip Calculation ErrorFault · Motor identification
End5Resistance Tuning ErrorFault · Motor identification
End6Leakage Inductance AlarmFault · Motor identification
End7No-Load Current AlarmFault · Motor identification
End8HFI AlarmFault · Motor identification
End9Initial Pole Detection AlarmFault · Motor identification
Er-01Motor Data ErrorFault · Motor identification
Er-02Drive in an Alarm StateFault · Motor identification
Er-03STOP Button was PressedThe STOP key was pressed during Auto-Tuning. Do Auto-Tuning again.Fault · Motor identification
Er-04Resistance Tuning ErrorFault · Motor identification
Er-05No-Load Current AlarmFault · Motor identification
Er-08Rated Slip ErrorFault · Motor identification
Er-09Acceleration ErrorFault · Motor identification
Er-10Motor Direction ErrorFault · Motor identification
Er-11Motor Speed ErrorFault · Motor identification
Er-12Current Detection ErrorFault · Motor identification
Er-13Leakage Inductance AlarmFault · Motor identification
Er-14Motor Speed Error 2The motor speed went above twice the speed reference amplitude during Inertia Tuning. Lower C5-01 (ASR Proportional Gain 1).Fault · Motor identification
Er-15Torque Saturation ErrorFault · Motor identification
Er-16Inertia ID ErrorFault · Motor identification
Er-17Reverse Prohibited ErrorReverse is disabled (b1-04 = 1); Inertia Tuning needs the motor to turn in reverse. Allow reverse on the machine, set b1-04 = 0, and do Inertia Tuning again.Fault · Motor identification
Er-18Back EMF ErrorThe induced voltage tuning result was outside range. Make sure the motor nameplate data entered is correct.Fault · Motor identification
Er-19PM Inductance ErrorThe PM motor inductance result was outside range. Make sure the motor nameplate data entered is correct.Fault · Motor identification
Er-20Stator Resistance ErrorThe PM motor stator resistance result was outside range. Make sure the motor nameplate data entered is correct.Fault · Motor identification
Er-25HighFreq Inject Param Tuning ErrThe motor data is incorrect. Do Stationary Auto-Tuning again; if Er-25 returns after it, the motor may not suit high frequency injection control.Fault · Motor identification

Related

Related pages

Source

Yaskawa, GA500 Drive Technical Reference, C, SIEP C710617 52, 7 Troubleshooting (7.4 to 7.7, 7.9).

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Yaskawa and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

GA500 fault you can't clear?

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.