The GA500 is Yaskawa's versatile compact AC drive, covering 200 V single-phase input up to 5 HP, 200 V three-phase up to 30 HP and 400 V three-phase up to 40 HP. It runs induction, permanent magnet and synchronous reluctance motors, and takes an LED or Bluetooth LCD keypad.
GA500 codes appear on the keypad as short letter codes, such as oC, ov, GF, oL1 or CPF06, and most are shared with Yaskawa's A1000 and V1000. Below is every fault, minor fault and alarm, parameter setting error (oPE) and Auto-Tuning error (End, Er) in the technical reference's troubleshooting chapter, with the causes and solutions Yaskawa gives.
01 / Reading codes
Reading and clearing GA500 codes
The keypad shows the code. For a fault, ALM/ERR stays lit; for a minor fault or alarm it flashes. Several codes, such as ov, CE, oH and the external faults EF1 to EF7, can appear as either, so note which.
A fault shuts off the drive's output and the motor coasts to a stop (some faults let you choose the stopping method). ALM/ERR stays lit, a terminal set to H2-01 to H2-03 = E activates, and the drive will not run until the fault is reset. A minor fault or alarm leaves the drive running the motor (some let you choose a stopping method) while ALM/ERR flashes. A minor fault activates a terminal set to H2-01 to H2-03 = 10; an alarm gives no signal. No fault reset is needed.
- Remove the cause, then reset in one of three ways: the reset key on the keypad while the code is shown, a multi-function input set to H1-xx = 14 (terminal S4 by default), or switching off the main circuit power and switching it back on once the keypad display has gone out.
- A fault will not reset while a run command is active from the terminals or a communication option; the keypad shows CrST until the run command is removed.
- oL1 resets only once monitor U4-16 (Motor oL1 Level) is below 100.
02 / Current and earth faults
Current and earth faults
| Code | Name | Kind |
|---|---|---|
| GF | Ground Fault | Fault · Earth fault |
| LF | Output Phase Loss | Fault · Output phase loss |
| LF2 | Output Current Imbalance | Fault · Output phase loss |
| oC | Overcurrent | Fault · Overcurrent |
| oC2 | Overcurrent2In OLV/PM, AOLV/PM or EZOLV (A1-02 = 5, 6 or 8), the output current went above L8-27 (Overcurrent Detection Gain). Correct L8-27. | Fault · Overcurrent |
| SC | Short Circuit/IGBT Failure | Fault · Output short circuit |
| HCA | High Current Alarm | Alarm · Overcurrent |
03 / Voltage and supply
Voltage and supply
| Code | Name | Kind |
|---|---|---|
| boL | Braking Transistor Overload Fault | Fault · Braking resistor |
| oL7 | High Slip Braking Overload | Fault · Braking resistor |
| ov | Overvoltage | Fault · DC bus overvoltage |
| PF | Input Phase Loss | Fault · Input phase loss |
| rF | Braking Resistor Fault | Fault · Braking resistor |
| rH | Braking Resistor Overheat | Fault · Braking resistor |
| rr | Dynamic Braking Transistor FaultThe drive's control circuit is damaged, or its internal braking transistor has failed. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Braking resistor |
| Uv1 | DC Bus Undervoltage | Fault · DC bus undervoltage |
| Uv2 | Control Power Undervoltage | Fault · DC bus undervoltage |
| EP24v | External Power 24V SupplyThe main circuit supply voltage fell, and the 24 V supply is powering the drive. Examine the main circuit supply and switch it on to run the drive. | Alarm · DC bus undervoltage |
| L24v | Loss of External Power 24 SupplyThe backup 24 V supply voltage fell while the main circuit supply is working. Examine the external 24 V supply and its wiring, and repair problems. | Alarm · DC bus undervoltage |
| Uv | DC Bus Undervoltage | Alarm · DC bus undervoltage |
04 / Temperature and overload
Temperature and overload
| Code | Name | Kind |
|---|---|---|
| oH | Heatsink Overheat | Fault · Drive overtemperature |
| oH1 | Heatsink Overheat | Fault · Drive overtemperature |
| oH3 | Motor Overheat (PTC Input) | Fault · Motor overload or overtemperature |
| oH4 | Motor Overheat Fault (PTC Input) | Fault · Motor overload or overtemperature |
| oL1 | Motor Overload | Fault · Motor overload or overtemperature |
| oL2 | Drive Overload | Fault · Drive overload |
| LT-1 | Cooling Fan Maintenance TimeThe cooling fan is at 90% of its expected life. Replace the cooling fan and set o4-03 = 0 to reset its operation time. | Alarm · Cooling fan |
| oH2 | External Overheat (H1-XX=B)An external device sent an overheat alarm through an input set to H1-xx = B. Find the device that sent the alarm, remove the cause, and clear the input on S1 to S7. | Alarm · Drive overtemperature |
05 / Motor and load
Motor and load
| Code | Name | Kind |
|---|---|---|
| CP1 | Comparator 1 Limit FaultThe monitor value selected in H2-20 was within the range of H2-21 (lower limit) and H2-22 (upper limit). Examine the monitor value and remove the cause. | Fault · Process limit |
| CP2 | Comparator 2 Limit FaultThe monitor value selected in H2-26 was outside the range of H2-27 (lower limit) and H2-28 (upper limit). Examine the monitor value and remove the cause. | Fault · Process limit |
| FbH | Excessive PID Feedback | Fault · Process limit |
| FbL | PID Feedback Loss | Fault · Process limit |
| LSo | Low Speed Motor Step-Out | Fault · Motor stall |
| oL3 | Overtorque Detection 1 | Fault · Load monitoring |
| oL4 | Overtorque Detection 2 | Fault · Load monitoring |
| oL5 | Mechanical Weakening Detection 1The drive detected overtorque under the mechanical weakening conditions set in L6-08. Do a deterioration diagnosis on the machine. | Fault · Load monitoring |
| STPo | Motor Step-Out Detected | Fault · Motor stall |
| UL3 | Undertorque Detection 1 | Fault · Load monitoring |
| UL4 | Undertorque Detection 2 | Fault · Load monitoring |
| UL5 | Mechanical Weakening Detection 2The drive detected undertorque under the mechanical weakening conditions set in L6-08. Examine the machine for deterioration. | Fault · Load monitoring |
06 / Signals and communication
Signals and communication
| Code | Name | Kind |
|---|---|---|
| bCE | Bluetooth Communication Fault | Fault · Communication loss |
| bUS | Option Communication Error | Fault · Communication loss |
| CE | Modbus Communication Error | Fault · Communication loss |
| dEv | Speed Deviation | Fault · Encoder signal |
| dWF2 | DriveWorksEZ Fault 2A fault in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause. | Fault · External fault |
| dWF3 | DriveWorksEZ Fault 3A fault in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause. | Fault · External fault |
| dWFL | DriveWorksEZ FaultA fault in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause. | Fault · External fault |
| E5 | MECHATROLINK Watchdog Timer ErrThe drive detected a watchdog circuit exception while receiving data from the controller. Check the MECHATROLINK cable connection; if it recurs, check the wiring and reduce interference following the MECHATROLINK-II or -III installation manuals. | Fault · Communication loss |
| EF0 | Option Card External Fault | Fault · External fault |
| EF1 | External Fault (Terminal S1) | Fault · External fault |
| EF2 | External Fault (Terminal S2) | Fault · External fault |
| EF3 | External Fault (Terminal S3) | Fault · External fault |
| EF4 | External Fault (Terminal S4) | Fault · External fault |
| EF5 | External Fault (Terminal S5) | Fault · External fault |
| EF6 | External Fault (Terminal S6) | Fault · External fault |
| EF7 | External Fault (Terminal S7) | Fault · External fault |
| oFA00 | Option Not Compatible with PortThe option on connector CN5 is not compatible. Connect a compatible option. | Fault · Communication loss |
| oFA01 | Option Fault/Connection ErrorThe option card on CN5 was changed during operation. De-energize the drive and connect the option card correctly, following its manual. | Fault · Communication loss |
| oFA03 | Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA04 | Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA05 | Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA06 | Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA10 | Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA11 | Option Card Error Occurred at Option Port CN5A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA12 | Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA13 | Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA14 | Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA15 | Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA16 | Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA17 | Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA30 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA31 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA32 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA33 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA34 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA35 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA36 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA37 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA38 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA39 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA40 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA41 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA42 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oFA43 | Communication Option Card Connection Error (CN5)A fault occurred in the option card on port CN5. De-energize the drive, make sure the option card is seated correctly in its connector, and re-energize; if the problem continues, replace the option card. | Fault · Communication loss |
| oPr | Keypad Connection Fault | Fault · Communication loss |
| oS | Overspeed | Fault · Encoder signal |
| PE1 | PLC FaultsThe communication option detected a fault. See the communication option card's manual. | Fault · Communication loss |
| PE2 | PLC FaultsThe communication option detected a fault. See the communication option card's manual. | Fault · Communication loss |
| PGo | Encoder (PG) Feedback Loss | Fault · Encoder signal |
| SCF | Safety Circuit FaultThe safety circuit is broken. Replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Safety input |
| AEr | Station Address Setting Error | Alarm · Communication loss |
| bb | BaseblockAn external baseblock command on input S1 to S7 stopped the drive's output. Check the sequence and timing of the baseblock input. | Alarm · External fault |
| CALL | Serial Comm Transmission Error | Alarm · Communication loss |
| CyC | MECHATROLINK CommCycleSettingErrThe controller's communication cycle is outside the MECHATROLINK option's permitted range. Set the controller's communication cycle within the option's range. | Alarm · Communication loss |
| dWA2 | DriveWorksEZ Alarm 2An error in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause. | Alarm · External fault |
| dWA3 | DriveWorksEZ Alarm 3An error in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause. | Alarm · External fault |
| dWAL | DriveWorksEZ AlarmAn error in the DriveWorksEZ program; not a drive fault. Examine the DriveWorksEZ program and remove the cause. | Alarm · External fault |
| PASS | Modbus Communication TestThe MEMOBUS/Modbus communication test completed. PASS clears once test mode is ended. | Alarm · Communication loss |
| SE | Modbus Test Mode ErrorMEMOBUS/Modbus self-diagnostics (H1-xx = 67) was run while the drive was running. Stop the drive, then run the self-diagnostics. | Alarm · Communication loss |
| SToF | Safe Torque OFF Hardware | Alarm · Safety input |
07 / Setup, memory and internal
Setup, memory and internal
| Code | Name | Kind |
|---|---|---|
| bAT | Keypad Battery Low VoltageThe keypad battery voltage is low. Replace the keypad battery. | Fault · Internal drive fault |
| CF | Control Fault | Fault · Setup |
| CoF | Current Offset Fault | Fault · Internal drive fault |
| CPF00 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF01 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF02 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF03 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF06 | Control Circuit Error (EEPROM memory Data Error) | Fault · Parameter memory |
| CPF08 | Terminal Board Connection ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF11 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF12 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF13 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF14 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF16 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF17 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF18 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF19 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF20 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF21 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF22 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF23 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF24 | Control Circuit ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| CPF25 | Terminal Board not ConnectedThe terminal board is not connected to the drive correctly. De-energize the drive, connect the terminal board correctly, and re-energize. | Fault · Internal drive fault |
| CPF38 | EEPROM Memory Data ErrorA drive hardware problem occurred. Re-energize the drive; if the fault stays, replace the control board or the drive (contact Yaskawa about replacing the control board). | Fault · Internal drive fault |
| dCE1 | Communication Error1A temporary drive hardware problem caused by noise. Remove the source of the noise. | Fault · Internal drive fault |
| dCE2 | Communication Error2A temporary drive hardware problem caused by noise. Remove the source of the noise. | Fault · Internal drive fault |
| dv7 | Polarity Judge Timeout | Fault · Motor identification |
| dWF1 | EEPROM Memory DWEZ Data Error | Fault · Parameter memory |
| Err | EEPROM Write Error | Fault · Parameter memory |
| nSE | Node Setup ErrorThe Node Setup input (H1-xx = 47, CANopen) was activated during run, or a run command came while Node Setup was active. Stop the drive while Node Setup is in use. | Fault · Setup |
| SEr | Speed Search Retries Exceeded | Fault · Automatic restart limit |
| TiM | Keypad Time Not SetThe keypad has a battery, but the date and time are not set. Set the date and time on the keypad. | Fault · Setup |
| Uv3 | Soft Charge Answerback Fault | Fault · Internal drive fault |
| bUSy | Busy | Alarm · Setup |
| CrST | Remove RUN Command to ResetA fault reset command arrived while a run command was active. Turn off the run command, then de-energize and re-energize the drive. | Alarm · Setup |
| CyPo | Cycle Power to Accept ChangesF6-15 = 1 (reload now) was set, but the drive has not updated the communication option parameters. Re-energize the drive. | Alarm · Setup |
| dnE | Drive DisabledA terminal set to H1-xx = 6A (Drive Enable) turned off. Check the operation sequence. | Alarm · Setup |
| EF | FWD/REV Run Command Input ErrorForward and reverse commands were both input for longer than 0.5 s. The motor ramps to stop. Check the forward and reverse command sequence and correct it. | Alarm · Setup |
| LoG | Log Com Error | Alarm · Parameter memory |
| LT-2 | Capacitor Maintenance TimeThe main and control circuit capacitors are at 90% of expected life. Replace the control board or the drive (contact Yaskawa about replacing the control board). | Alarm · Internal drive fault |
| LT-3 | SoftChargeBypassRelay MainteTimeThe soft charge bypass relay is at 90% of its expected life. Replace the control board or the drive (contact Yaskawa about replacing the control board). | Alarm · Internal drive fault |
| LT-4 | IGBT Maintenance Time (50%)The IGBTs are at 50% of expected life. Check the load, carrier frequency and output frequency. | Alarm · Internal drive fault |
| ovEr | Too Many Parameters ChangedMore than 150 parameters were changed (fewer if some have dependencies). Return parameters that do not affect operation to their defaults. | Alarm · Setup |
| rUn | Motor Switch during RunMotor 2 Selection (H1-xx = 16) was input during run. Switch motors only while the drive is stopped. | Alarm · Setup |
| TrPC | IGBT Maintenance Time (90%)The IGBTs are at 90% of expected life. Replace the IGBT or the drive. | Alarm · Internal drive fault |
| oPE01 | Drive Capacity Setting Erroro2-04 (Drive Model) does not match the drive. Set o2-04 correctly. | Fault · Setup |
| oPE02 | Parameter Range Setting Error | Fault · Setup |
| oPE03 | Multi-Function Input Setting Err | Fault · Setup |
| oPE05 | Run Cmd/Freq Ref Source Sel Err | Fault · Setup |
| oPE07 | Analog Input Selection Error | Fault · Setup |
| oPE08 | Parameter Selection Error | Fault · Setup |
| oPE09 | PID Control Selection Fault | Fault · Setup |
| oPE10 | V/f Data Setting ErrorThe V/f pattern does not follow E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04 (E3 parameters for motor 2). Correct the V/f parameters to meet the rule. | Fault · Setup |
| oPE11 | Carrier Frequency Setting Error | Fault · Setup |
| oPE13 | Pulse Monitor Selection ErrorH6-07 = 0 while H6-06 is not 101, 102, 105 or 116. Set H6-06 correctly. | Fault · Setup |
| oPE16 | Energy Saving Constants ErrorThe energy saving parameters are outside their ranges. Set the E5 parameters from the motor nameplate. | Fault · Setup |
| oPE33 | Digital Output Selection Error | Fault · Setup |
| End1 | Excessive Rated Voltage Setting | Fault · Motor identification |
| End2 | Iron Core Saturation Coefficient | Fault · Motor identification |
| End3 | Rated Current Setting AlarmThe rated current entered is incorrect. Tune again with the rated current from the motor nameplate. | Fault · Motor identification |
| End4 | Adjusted Slip Calculation Error | Fault · Motor identification |
| End5 | Resistance Tuning Error | Fault · Motor identification |
| End6 | Leakage Inductance Alarm | Fault · Motor identification |
| End7 | No-Load Current Alarm | Fault · Motor identification |
| End8 | HFI Alarm | Fault · Motor identification |
| End9 | Initial Pole Detection Alarm | Fault · Motor identification |
| Er-01 | Motor Data Error | Fault · Motor identification |
| Er-02 | Drive in an Alarm State | Fault · Motor identification |
| Er-03 | STOP Button was PressedThe STOP key was pressed during Auto-Tuning. Do Auto-Tuning again. | Fault · Motor identification |
| Er-04 | Resistance Tuning Error | Fault · Motor identification |
| Er-05 | No-Load Current Alarm | Fault · Motor identification |
| Er-08 | Rated Slip Error | Fault · Motor identification |
| Er-09 | Acceleration Error | Fault · Motor identification |
| Er-10 | Motor Direction Error | Fault · Motor identification |
| Er-11 | Motor Speed Error | Fault · Motor identification |
| Er-12 | Current Detection Error | Fault · Motor identification |
| Er-13 | Leakage Inductance Alarm | Fault · Motor identification |
| Er-14 | Motor Speed Error 2The motor speed went above twice the speed reference amplitude during Inertia Tuning. Lower C5-01 (ASR Proportional Gain 1). | Fault · Motor identification |
| Er-15 | Torque Saturation Error | Fault · Motor identification |
| Er-16 | Inertia ID Error | Fault · Motor identification |
| Er-17 | Reverse Prohibited ErrorReverse is disabled (b1-04 = 1); Inertia Tuning needs the motor to turn in reverse. Allow reverse on the machine, set b1-04 = 0, and do Inertia Tuning again. | Fault · Motor identification |
| Er-18 | Back EMF ErrorThe induced voltage tuning result was outside range. Make sure the motor nameplate data entered is correct. | Fault · Motor identification |
| Er-19 | PM Inductance ErrorThe PM motor inductance result was outside range. Make sure the motor nameplate data entered is correct. | Fault · Motor identification |
| Er-20 | Stator Resistance ErrorThe PM motor stator resistance result was outside range. Make sure the motor nameplate data entered is correct. | Fault · Motor identification |
| Er-25 | HighFreq Inject Param Tuning ErrThe motor data is incorrect. Do Stationary Auto-Tuning again; if Er-25 returns after it, the motor may not suit high frequency injection control. | Fault · Motor identification |
Related
Related pages
Source
Yaskawa, GA500 Drive Technical Reference, C, SIEP C710617 52, 7 Troubleshooting (7.4 to 7.7, 7.9).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Yaskawa and is not its authorised service partner.