The FANUC Series 0i-MODEL D and 0i Mate-MODEL D are CNC controls for machining centres and lathes, driving FANUC servo amplifiers over the FSSB optical link and FANUC serial spindle amplifiers. On the alarm screen, every alarm is a two-letter type and a four-digit number with FANUC's message, such as SV0401 IMPROPER V_READY OFF, OT0506 + OVERTRAVEL ( HARD ) or SP9073 MOTOR SENSOR DISCONNECTED.
Below are the servo, spindle, overtravel, overheat, memory, power-off and other (DS) alarms from the 0i-D maintenance manual's alarm list, the serial spindle alarms from SP9001 with the number the spindle amplifier shows, and the troubleshooting steps the manual gives for the most common ones. Program and operation (PS) alarms have their own list: FANUC 0i-D Program (PS) alarm codes.
01 / Reading codes
Reading and clearing 0i-D codes
The alarm screen shows the type, number and message, for example SV0401 IMPROPER V_READY OFF. Serial spindle alarms appear on the CNC as SP9001 and up; the spindle amplifier's own display shows the two-digit number (01 for SP9001) with its red LED lit. A number with the yellow LED lit is a sequence error code instead, not an alarm.
FANUC calls every code an alarm and groups them by type: SV servo, SP spindle, OT overtravel, OH overheat, IO memory file, PW power off required, DS other alarms, IE malfunction prevention, and PS, BG and SR for program, background edit and communication. An alarm stops operation until its cause is removed and it is cleared.
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
02 / Current and earth faults
Current and earth faults
| Code | Name | Kind |
|---|---|---|
| SV0437 | CNV. OVERCURRENT POWEROvercurrent in the power supply's input circuit. | Alarm · Overcurrent |
| SV0438 | INV. ABNORMAL CURRENTMotor overcurrent in the servo amplifier. | Alarm · Overcurrent |
| SV0449 | INV. IPM ALARMThe servo amplifier's IPM (intelligent power module) detected an alarm. | Alarm · Overcurrent |
| SV0600 | INV. DC LINK OVER CURRENTDC link overcurrent in the servo amplifier. | Alarm · Overcurrent |
| SP9012 | OVERCURRENT POWER CIRCUIT | Alarm · Overcurrent |
| SP9030 | OVERCURRENT INPUT CIRCUITOvercurrent in the power supply's main circuit input (power supply alarm 1): an unbalanced supply, or a power supply too small. Check and correct the supply voltage. | Alarm · Overcurrent |
03 / Voltage and supply
Voltage and supply
| Code | Name | Kind |
|---|---|---|
| SV0401 | IMPROPER V_READY OFF | Alarm · Servo ready |
| SV0404 | IMPROPER V_READY ON | Alarm · Servo ready |
| SV0432 | CNV. LOW VOLT CONTROLThe control power voltage of the power supply or servo amplifier has dropped. | Alarm · DC bus undervoltage |
| SV0433 | CNV. LOW VOLT DC LINKLow DC link voltage in the power supply or servo amplifier. | Alarm · DC bus undervoltage |
| SV0434 | INV. LOW VOLT CONTROLLow control power voltage in the servo amplifier. | Alarm · DC bus undervoltage |
| SV0435 | INV. LOW VOLT DC LINKLow DC link voltage in the servo amplifier. | Alarm · DC bus undervoltage |
| SV0439 | CNV. OVER VOLT DC LINKThe DC link voltage of the power supply or servo amplifier is too high. | Alarm · DC bus overvoltage |
| SV0440 | CNV. EX DECELERATION POW.Too much regenerative discharge in the power supply or servo amplifier, or a fault in the regenerative circuit. | Alarm · Braking resistor |
| SV0442 | CNV. CHARGE FAILUREThe power supply's DC link pre-charge circuit is abnormal. | Alarm · DC bus undervoltage |
| SV0605 | CNV. EX. DISCHARGE POW.The motor's regenerative power is too high for the power supply. | Alarm · Braking resistor |
| SV0607 | CNV. SINGLE PHASE FAILUREA phase is missing from the power supply's input. | Alarm · Input phase loss |
| SV1025 | V_READY ON (INITIALIZING )The servo amplifier's ready signal (VRDY), which should be off, is on while servo control is on. | Alarm · Servo ready |
| SP9004 | POWER SUPPLY ERRORThe power supply found a missing input phase (power supply alarm E). Check the input voltage to the power supply and its connections. | Alarm · Input phase loss |
| SP9010 | LOW VOLT INPUT POWER | Alarm · DC bus undervoltage |
| SP9011 | OVERVOLT POWER CIRCUIT | Alarm · DC bus overvoltage |
| SP9033 | SHORTAGE POWER CHARGE | Alarm · DC bus undervoltage |
| SP9051 | LOW VOLT POWER CIRCUIT | Alarm · DC bus undervoltage |
| SP9057 | CONV. EX. DECELERATION POW. | Alarm · Braking resistor |
| SP9111 | CONV. LOW VOLT CONTROLLow control power voltage in the power supply (power supply shows 6). Replace the power supply's control printed circuit board. | Alarm · DC bus undervoltage |
| SP9112 | CONV. EX. DISCHARGE POW. | Alarm · Braking resistor |
04 / Temperature and overload
Temperature and overload
| Code | Name | Kind |
|---|---|---|
| SV0430 | SV MOTOR OVERHEATThe servo motor has overheated. | Alarm · Motor overload or overtemperature |
| SV0431 | CNV. OVERLOADThe power supply or servo amplifier has overheated. | Alarm · Drive overtemperature |
| SV0436 | SOFTTHERMAL(OVC)The digital servo software detected a software thermal (OVC). | Alarm · Motor overload or overtemperature |
| SV0443 | CNV. COOLING FAN FAILUREAn internal cooling fan has failed in the power supply or servo amplifier. | Alarm · Cooling fan |
| SV0444 | INV. COOLING FAN FAILUREThe servo amplifier's internal cooling fan has failed. | Alarm · Cooling fan |
| SV0601 | INV. RADIATOR FAN FAILUREThe servo amplifier's external radiator fan has failed. | Alarm · Cooling fan |
| SV0602 | INV. OVERHEATThe manual describes this as the servo motor overheating. | Alarm · Motor overload or overtemperature |
| SV0603 | INV. IPM ALARM(OH)The servo amplifier's IPM detected an overheat. | Alarm · Drive overtemperature |
| SV0606 | CNV. RADIATOR FAN FAILUREThe power supply's external radiator fan has failed. | Alarm · Cooling fan |
| SP9001 | MOTOR OVERHEAT | Alarm · Motor overload or overtemperature |
| SP9006 | THERMAL SENSOR DISCONNECT | Alarm · Temperature sensor signal |
| SP9009 | OVERHEAT MAIN CIRCUIT | Alarm · Drive overtemperature |
| SP9022 | SERIAL SPINDLE ALARM | Alarm · Drive overload |
| SP9029 | OVERLOADAn excessive load continued for a set time, including the motor shaft locked while excited. Check and correct the load. | Alarm · Drive overload |
| SP9054 | OVERCURRENTAn overload current was detected. Review the load. | Alarm · Drive overload |
| SP9056 | COOLING FAN FAILUREThe internal cooling fan stopped. Replace the internal cooling fan. | Alarm · Cooling fan |
| SP9058 | CNV. OVERLOAD | Alarm · Drive overtemperature |
| SP9059 | CNV. COOLING FAN FAILUREThe power supply's internal cooling fan stopped (power supply alarm 2). Replace the power supply. | Alarm · Cooling fan |
| SP9088 | COOLING RADI FAN FAILUREThe spindle amplifier's external radiator fan stopped. Replace the external radiator fan. | Alarm · Cooling fan |
| SP9113 | CONV. COOLING FAN FAILUREThe power supply's external radiator fan stopped (power supply shows A). Replace the power supply's external radiator fan. | Alarm · Cooling fan |
| OH0704 | OVERHEAT | Alarm · Motor overload or overtemperature |
05 / Motor and load
Motor and load
| Code | Name | Kind |
|---|---|---|
| SV0409 | DETECT ABNORMAL TORQUEAn abnormal load was detected on the servo motor, or on the Cs axis or spindle positioning axis. The alarm can be cancelled with RESET. | Alarm · Load monitoring |
| SV0410 | EXCESS ERROR (STOP)The positional deviation with the axis stopped went above parameter No. 1829. | Alarm · Motor stall |
| SV0411 | EXCESS ERROR (MOVING)The positional deviation with the axis moving went above parameter No. 1828. | Alarm · Motor stall |
| OT0500 | + OVERTRAVEL ( SOFT 1 )The axis passed stored stroke check 1 on the positive side. | Alarm · Overtravel |
| OT0501 | - OVERTRAVEL ( SOFT 1 )The axis passed stored stroke check 1 on the negative side. | Alarm · Overtravel |
| OT0502 | + OVERTRAVEL ( SOFT 2 )The axis passed stored stroke check 2 on the positive side (on lathes, also an entry into the chuck and tailstock barrier moving positive). | Alarm · Overtravel |
| OT0503 | - OVERTRAVEL ( SOFT 2 )The axis passed stored stroke check 2 on the negative side (on lathes, also an entry into the chuck and tailstock barrier moving negative). | Alarm · Overtravel |
| OT0504 | + OVERTRAVEL ( SOFT 3 )The axis passed stored stroke check 3 on the positive side. | Alarm · Overtravel |
| OT0505 | - OVERTRAVEL ( SOFT 3 )The axis passed stored stroke check 3 on the negative side. | Alarm · Overtravel |
| OT0506 | + OVERTRAVEL ( HARD ) | Alarm · Overtravel |
| OT0507 | - OVERTRAVEL ( HARD ) | Alarm · Overtravel |
| OT0508 | INTERFERENCE:+On a lathe, a tool moving positive along the axis fouled another tool post. | Alarm · Overtravel |
| OT0509 | INTERFERENCE:-On a lathe, a tool moving negative along the axis fouled another tool post. | Alarm · Overtravel |
| OT0510 | + OVERTRAVEL ( PRE-CHECK )The stroke check made before the move found the tool would pass a limit. | Alarm · Overtravel |
| OT0511 | - OVERTRAVEL ( PRE-CHECK )The stroke check made before the move found the tool would pass a limit. | Alarm · Overtravel |
| SP0740 | RIGID TAP ALARM : EXCESS ERRORDuring rigid tapping, the stopped spindle's positional deviation went above its setting. | Alarm · Motor stall |
| SP0741 | RIGID TAP ALARM : EXCESS ERRORDuring rigid tapping, the moving spindle's positional deviation went above its setting. | Alarm · Motor stall |
| SP0754 | ABNORMAL TORQUEAn abnormal load was detected on the spindle motor. The alarm can be cancelled with RESET. | Alarm · Load monitoring |
| SP1231 | SPINDLE EXCESS ERROR (MOVING)The spindle's positional deviation while rotating went above its parameter setting. | Alarm · Motor stall |
| SP1232 | SPINDLE EXCESS ERROR (STOP)The spindle's positional deviation while stopped went above its parameter setting. | Alarm · Motor stall |
| SP9002 | EX DEVIATION SPEED | Alarm · Motor stall |
| SP9031 | MOTOR LOCK OR DISCONNECT DETECTOR | Alarm · Motor stall |
| IE0001 | + OVERTRAVEL ( SOFT 1 )The malfunction prevention function found stored stroke check 1 exceeded on the positive side. | Alarm · Overtravel |
| IE0002 | - OVERTRAVEL ( SOFT 1 )The malfunction prevention function found stored stroke check 1 exceeded on the negative side. | Alarm · Overtravel |
06 / Signals and communication
Signals and communication
| Code | Name | Kind |
|---|---|---|
| SV0301 | APC ALARM: COMMUNICATION ERRORA communication error from the absolute position detector, so the machine position could not be read: the detector, its cable or the servo interface module is suspect. | Alarm · Encoder signal |
| SV0302 | APC ALARM: OVER TIME ERRORAn overtime error from the absolute position detector, so the machine position could not be read: the detector, its cable or the servo interface module is suspect. | Alarm · Encoder signal |
| SV0303 | APC ALARM: FRAMING ERRORA framing error from the absolute position detector, so the machine position could not be read: the detector, its cable or the servo interface module is suspect. | Alarm · Encoder signal |
| SV0304 | APC ALARM: PARITY ERRORA parity error from the absolute position detector, so the machine position could not be read: the detector, its cable or the servo interface module is suspect. | Alarm · Encoder signal |
| SV0305 | APC ALARM: PULSE ERRORA pulse error from the absolute position detector, so the machine position could not be read: the detector or its cable is suspect. | Alarm · Encoder signal |
| SV0306 | APC ALARM: OVER FLOW ERRORThe positional deviation overflowed, so the machine position could not be read. Check parameters No. 2084 and No. 2085. | Alarm · Encoder signal |
| SV0307 | APC ALARM: MOVEMENT EXCESS ERRORThe machine moved too far for the correct position to be read. | Alarm · Encoder signal |
| SV0360 | ABNORMAL CHECKSUM(INT)A checksum alarm on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0361 | ABNORMAL PHASE DATA(INT)A phase data alarm on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0362 | ABNORMAL REV. DATA(INT)A speed count alarm on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0363 | ABNORMAL CLOCK(INT)A clock alarm on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0364 | SOFT PHASE ALARM(INT)The digital servo software found an abnormality on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0365 | BROKEN LED(INT)The digital servo software found abnormal data from the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0366 | PULSE MISS(INT)A pulse error on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0367 | COUNT MISS(INT)A count error on the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0368 | SERIAL DATA ERROR(INT)No communication data could be received from the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0369 | DATA TRANS. ERROR(INT)A CRC or stop bit error in the data from the built-in Pulsecoder. | Alarm · Encoder signal |
| SV0380 | BROKEN LED(EXT)A separate (external) detector error. | Alarm · Encoder signal |
| SV0381 | ABNORMAL PHASE (EXT)Abnormal position data from the separate detector. | Alarm · Encoder signal |
| SV0382 | COUNT MISS(EXT)A count error on the separate detector. | Alarm · Encoder signal |
| SV0383 | PULSE MISS(EXT)A pulse error on the separate detector. | Alarm · Encoder signal |
| SV0384 | SOFT PHASE ALARM(EXT)The digital servo software found abnormal data from the separate detector. | Alarm · Encoder signal |
| SV0385 | SERIAL DATA ERROR(EXT)No communication data could be received from the separate detector. | Alarm · Encoder signal |
| SV0386 | DATA TRANS. ERROR(EXT)A CRC or stop bit error in the data from the separate detector. | Alarm · Encoder signal |
| SV0387 | ABNORMAL ENCODER(EXT)An abnormality on the separate detector; the scale maker has the details. | Alarm · Encoder signal |
| SV0421 | EXCESS ERROR(SEMI-FULL)The difference between the semi-closed and full-closed feedback went above its parameter setting. | Alarm · Encoder signal |
| SV0445 | SOFT DISCONNECT ALARMThe digital servo software detected a disconnected Pulsecoder. | Alarm · Encoder signal |
| SV0446 | HARD DISCONNECT ALARMThe hardware detected a disconnected built-in Pulsecoder. | Alarm · Encoder signal |
| SV0447 | HARD DISCONNECT(EXT)The hardware detected a disconnected separate detector. | Alarm · Encoder signal |
| SV0448 | UNMATCHED FEEDBACK ALARMThe separate detector's feedback sign is opposite to the built-in Pulsecoder's. | Alarm · Encoder signal |
| SV0453 | SPC SOFT DISCONNECT ALARM | Alarm · Encoder signal |
| SV0454 | ILLEGAL ROTOR POS DETECTMagnetic pole detection ended abnormally: the motor did not move, so the pole could not be found. | Alarm · Encoder signal |
| SV0460 | FSSB DISCONNECTThe FSSB connection was lost: the FSSB cable is disconnected or broken, an amplifier was switched off, or an amplifier had a low-voltage alarm. Check the FSSB optical cables and their connectors. | Alarm · Communication loss |
| SV0462 | SEND CNC DATA FAILED | Alarm · Communication loss |
| SV0463 | SEND SLAVE DATA FAILED | Alarm · Communication loss |
| SV0465 | READ ID DATA FAILEDReading the amplifier's ID information failed at power-on. | Alarm · Communication loss |
| SV0604 | AMP. COMMUNICATION ERRORCommunication between the servo amplifier and the power supply failed. | Alarm · Communication loss |
| SV1067 | FSSB:CONFIGURATION ERROR(SOFT)The software found an FSSB configuration error: the connected amplifier type does not match the FSSB settings. | Alarm · Communication loss |
| SV5134 | FSSB:OPEN READY TIME OUT | Alarm · Communication loss |
| SV5136 | FSSB:NUMBER OF AMP. IS INSUFFICIENT | Alarm · Communication loss |
| SV5137 | FSSB:CONFIGURATION ERROR | Alarm · Communication loss |
| SV5139 | FSSB:ERRORServo initialisation did not complete: an optical cable, or the connection between an amplifier and another module, has probably failed. | Alarm · Communication loss |
| SV5197 | FSSB:OPEN TIME OUT | Alarm · Communication loss |
| SP1220 | NO SPINDLE AMP.The cable to the serial spindle amplifier is broken, or the amplifier is not connected. | Alarm · Communication loss |
| SP1225 | CRC ERROR (SERIAL SPINDLE)A CRC (communication) error between the CNC and the serial spindle amplifier. | Alarm · Communication loss |
| SP1226 | FRAMING ERROR (SERIAL SPINDLE)A framing error between the CNC and the serial spindle amplifier. | Alarm · Communication loss |
| SP1227 | RECEIVING ERROR (SERIAL SPINDLE)A receive error between the CNC and the serial spindle amplifier. | Alarm · Communication loss |
| SP1228 | COMMUNICATION ERROR (SERIAL SPINDLE)A communication error between the CNC and the serial spindle amplifier. | Alarm · Communication loss |
| SP1229 | COMMUNICATION ERROR SERIAL SPINDLE AMP.A communication error between serial spindle amplifiers (motors 1 and 2, or 3 and 4). | Alarm · Communication loss |
| SP1240 | DISCONNECT POSITION CODERThe analog spindle's position coder is disconnected. | Alarm · Encoder signal |
| SP9021 | POS SENSOR POLARITY ERRORThe position sensor's polarity parameter is set wrongly. Check and correct parameters No. 4000 bit 0 and No. 4001 bit 4. | Alarm · Encoder signal |
| SP9024 | SERIAL TRANSFER ERROR | Alarm · Communication loss |
| SP9027 | DISCONNECT POSITION CODERThe spindle position coder signal (connector JYA3) is abnormal. Replace the cable. | Alarm · Encoder signal |
| SP9041 | ILLEGAL 1REV SIGN OF POSITION CODER | Alarm · Encoder signal |
| SP9042 | NO 1REV SIGN OF POSITION CODERThe position coder's one-rotation signal (connector JYA3) is missing. Replace the cable. | Alarm · Encoder signal |
| SP9043 | DISCONNECT POSITION CODER DEF. SPEEDThe differential speed position coder signal (connector JYA3S) in submodule SW is abnormal. Replace the cable. | Alarm · Encoder signal |
| SP9046 | ILLEGAL 1REV SIGN OF SCREW CUT | Alarm · Encoder signal |
| SP9047 | ILLEGAL SIGNAL OF POSITION CODER | Alarm · Encoder signal |
| SP9052 | ITP FAULT 1 | Alarm · Communication loss |
| SP9053 | ITP FAULT 2 | Alarm · Communication loss |
| SP9061 | SERIAL SPINDLE ALARMWith dual position feedback, the difference between the semi-closed and full-closed sides is too large. Check the parameter settings. | Alarm · Encoder signal |
| SP9065 | SERIAL SPINDLE ALARM | Alarm · Encoder signal |
| SP9066 | COM. ERROR BETWEEN SP AMPS | Alarm · Communication loss |
| SP9069 | SAFETY SPEED OVER | Alarm · Safety input |
| SP9072 | MISMATCH RESULT OF MOTOR SPEED CHECK | Alarm · Safety input |
| SP9073 | MOTOR SENSOR DISCONNECTED | Alarm · Encoder signal |
| SP9076 | INEXECUTION OF SAFETY FUNCTIONSThe spindle amplifier found that its safety functions were not executed. Replace the spindle amplifier's control printed circuit board. | Alarm · Safety input |
| SP9077 | MISMATCH RESULT OF AXIS NUMBER CHECK | Alarm · Safety input |
| SP9078 | MISMATCH RESULT OF SAFETY PARAMETER CHECK | Alarm · Safety input |
| SP9080 | ALARM AT THE OTHER SP AMP.During communication between spindle amplifiers, the other amplifier raised an alarm. Remove the cause of the other spindle amplifier's alarm. | Alarm · External fault |
| SP9081 | 1-ROT MOTOR SENSOR ERROR | Alarm · Encoder signal |
| SP9082 | NO 1-ROT MOTOR SENSOR | Alarm · Encoder signal |
| SP9083 | MOTOR SENSOR SIGNAL ERROR | Alarm · Encoder signal |
| SP9084 | SPNDL SENSOR DISCONNECTED | Alarm · Encoder signal |
| SP9085 | 1-ROT SPNDL SENSOR ERROR | Alarm · Encoder signal |
| SP9086 | NO 1-ROT SPNDL SENSOR | Alarm · Encoder signal |
| SP9087 | SPNDL SENSOR SIGNAL ERROR | Alarm · Encoder signal |
| SP9090 | SERIAL SPINDLE ALARM | Alarm · Encoder signal |
| SP9091 | SERIAL SPINDLE ALARMA count error in the synchronous spindle motor's magnetic pole position. Replace the motor sensor cable. | Alarm · Encoder signal |
| SP9110 | AMP COMMUNICATION ERROR | Alarm · Communication loss |
| SP9120 | COMMUNICATION DATA ERROR | Alarm · Communication loss |
| SP9121 | COMMUNICATION DATA ERROR | Alarm · Communication loss |
| SP9122 | COMMUNICATION DATA ERROR | Alarm · Communication loss |
| SP9132 | SERIAL SPINDLE ALARMA serial data error. Replace the sensor. | Alarm · Encoder signal |
| SP9133 | SERIAL SPINDLE ALARMA data transfer error. Replace the sensor. | Alarm · Encoder signal |
| SP9134 | SERIAL SPINDLE ALARM | Alarm · Encoder signal |
| SP9135 | SAFETY SPEED ZERO ERROR(SP)The motor position went outside the safety speed zero monitoring width. Operate within the safety speed zero range. | Alarm · Safety input |
| SP9136 | MISMATCH RESULT OF SAFETY SPEED ZERO CHECK(SP)The spindle amplifier's speed zero result did not match the CNC's. Replace the spindle amplifier's control printed circuit board. | Alarm · Safety input |
| SP9139 | SERIAL SPINDLE ALARMA pulse error. Replace the sensor. | Alarm · Encoder signal |
| SP9140 | SERIAL SPINDLE ALARM | Alarm · Encoder signal |
| SP9141 | SERIAL SPINDLE ALARM | Alarm · Encoder signal |
| DS0020 | REFERENCE RETURN INCOMPLETEAn automatic reference return on the perpendicular axis was attempted before the angular axis had returned. Return the angular axis to its reference position first, then the perpendicular axis. | Alarm · Reference position |
| DS0300 | APC ALARM: NEED REF RETURN | Alarm · Reference position |
| DS0306 | APC ALARM: BATTERY VOLTAGE 0 | Alarm · Reference position |
| DS0307 | APC ALARM: BATTERY LOW 1 | Alarm · Reference position |
| DS0308 | APC ALARM: BATTERY LOW 2The absolute position detector's battery dropped to the replacement level at some point in the past, including while powered off. Replace the battery with the machine powered on, so the stored position is kept. | Alarm · Reference position |
| DS0309 | APC ALARM: REF RETURN IMPOSSIBLE | Alarm · Reference position |
| DS0405 | ZERO RETURN END NOT ON REF | Alarm · Reference position |
| DS1449 | REFERENCE MARK ARE DIFFERENT FROM PARAMETEROn a distance-coded linear scale, the real reference mark interval differs from parameters No. 1821 and No. 1882. | Alarm · Reference position |
| DS1450 | ZERO RETURN NOT FINISHEDThe first reference return (07h) was commanded before any manual reference return since power-up, with parameter No. 1005 bit 0 (ZRN) at 0. | Alarm · Reference position |
| PS0090 | REFERENCE RETURN INCOMPLETE | Alarm · Reference position |
| IE0009 | ILLEGAL MCN COODINATEThe malfunction prevention function found the machine coordinate displaced at the check point. | Alarm · Reference position |
07 / Setup, memory and internal
Setup, memory and internal
| Code | Name | Kind |
|---|---|---|
| SW0100 | PARAMETER ENABLE SWITCH ONParameter writing is enabled (bit 0, PWE, of parameter No. 8900 is 1). Turn it off again once the parameters are set. | Alarm · Setup |
| SV0403 | CARD/SOFT MISMATCHThe axis card and the servo software do not match: the wrong axis card is fitted, or the wrong servo software is in flash memory. | Alarm · Internal drive fault |
| SV0413 | LSI OVERFLOWThe positional deviation counter overflowed. | Alarm · Setup |
| SV0415 | MOTION VALUE OVERFLOWA speed above the travel speed limit was commanded. | Alarm · Setup |
| SV0417 | ILL DGTL SERVO PARAMETER | Alarm · Setup |
| SV0422 | EXCESS VELOCITY IN TORQUEIn torque control, the permissible speed was exceeded. | Alarm · Setup |
| SV0423 | EXCESS ERROR IN TORQUEIn torque control, the permissible total move set in parameters was exceeded. | Alarm · Setup |
| SV0441 | ABNORMAL CURRENT OFFSETThe digital servo software found an abnormality in the motor current detection circuit. | Alarm · Internal drive fault |
| SV0466 | MOTOR/AMP. COMBINATIONThe amplifier's maximum current does not match the motor's: the amplifier connection setting or parameter No. 2165 is wrong. | Alarm · Setup |
| SV1026 | ILLEGAL AXIS ARRANGEThe servo axis numbers in parameter No. 1023 are negative, duplicated, or larger than the number of controlled axes. | Alarm · Setup |
| IO1001 | FILE ACCESS ERRORAn error in the resident file system prevented access to it. | Alarm · Parameter memory |
| IO1002 | FILE SYSTEM ERRORAn error in the CNC file system prevented access to a file. | Alarm · Parameter memory |
| IO1030 | CHECK SUM ERRORThe checksum of the part program memory is wrong. | Alarm · Parameter memory |
| IO1032 | MEMORY ACCESS OVER RANGEData was accessed outside the part program memory range. | Alarm · Parameter memory |
| IO1104 | OVER MAXIMUM TOOL LIFE PAIRSThe maximum number of tool life management pairs was exceeded. Change the maximum number of pairs in parameter No. 6813. | Alarm · Setup |
| PW0000 | POWER MUST BE OFF | Alarm · Setup |
| PW0001 | X-ADDRESS(*DEC) IS NOT ASSIGNED.The PMC X address for the reference return deceleration dog (*DEC) could not be assigned, while setting parameter No. 3013. | Alarm · Setup |
| PW0002 | PMC address is not correct(AXIS).The address for the axis signals is wrong: parameter No. 3021 is set incorrectly. | Alarm · Setup |
| PW0003 | PMC address is not correct(SPINDLE).The address for the spindle signals is wrong: parameter No. 3022 is set incorrectly. | Alarm · Setup |
| PW0006 | POWER MUST BE OFF (ILL-EXEC-CHK)The malfunction prevention function raised an alarm that needs the power switched off. | Alarm · Setup |
| PW0007 | X-ADDRESS(SKIP) IS NOT ASSIGNEDThe PMC X address for the skip signal (parameter No. 3012), or another X address (No. 3019), could not be assigned. | Alarm · Setup |
| PW1102 | ILLEGAL PARAMETER (I-COMP.)The slope compensation parameters are wrong: points out of order, outside the pitch error compensation range, or a compensation per point too small or large. | Alarm · Setup |
| PW1110 | ILLEGAL PARAMETER (SERVO MOTOR SPINDLE)The parameters for a spindle driven by a servo motor are set incorrectly. | Alarm · Setup |
| PW1111 | ILLEGAL SPINDLE NUMBER (SERVO MOTOR SPINDLE)The spindle number (No. 11010) or spindle amplifier number (No. 3717) for a servo-motor spindle is wrong. | Alarm · Setup |
| SP0742 | RIGID TAP ALARM : LSI OVERFLOWAn LSI overflow on the spindle during rigid tapping. | Alarm · Setup |
| SP0752 | SPINDLE MODE CHANGE ERRORA spindle mode change (Cs contour, spindle positioning, rigid tapping or spindle control) did not finish: the spindle control unit did not respond correctly. | Alarm · Setup |
| SP1202 | SPINDLE SELECT ERRORIn multi-spindle control, an invalid spindle number was selected by the position coder select signal. | Alarm · Setup |
| SP1221 | ILLEGAL MOTOR NUMBERThe spindle number and motor number are matched incorrectly. | Alarm · Setup |
| SP1224 | ILLEGAL SPINDLE-POSITION CODER GEAR RATIOThe spindle to position coder gear ratio is wrong. | Alarm · Setup |
| SP1241 | D/A CONVERTER ERRORThe D/A converter controlling the analog spindle has failed. | Alarm · Internal drive fault |
| SP1996 | ILLEGAL SPINDLE PARAMETER SETTINGA spindle is assigned incorrectly, or there are more spindles than the system allows. Check parameters No. 3701 bits 1 and 4, No. 3716 and No. 3717. | Alarm · Setup |
| SP9003 | DC-LINK FUSE IS BROKEN | Alarm · Internal drive fault |
| SP9007 | OVER SPEEDThe motor went above 115% of its rated speed, or in position control mode the positional deviation built up too far (SFR and SRV turned off during spindle synchronisation). Check for a sequence error, such as spindle synchronisation commanded when the spindle could not turn. | Alarm · Setup |
| SP9013 | CPU DATA MEMORY FAULTA fault in a spindle amplifier control component (internal RAM). Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| SP9014 | SERIAL SPINDLE ALARMThe spindle amplifier is not registered in the spindle software. Upgrade the spindle software. | Alarm · Internal drive fault |
| SP9015 | SPINDLE SWITCHING FAULT | Alarm · Setup |
| SP9016 | RAM ERRORA fault in a spindle amplifier control component (external data RAM). Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| SP9017 | SERIAL SPINDLE ALARMThe spindle amplifier's ID data is abnormal. Replace the spindle amplifier. | Alarm · Internal drive fault |
| SP9018 | SUMCHECK ERROR PROGRAM ROMA fault in a spindle amplifier control component (program ROM data). Replace the spindle amplifier's control printed circuit board. | Alarm · Parameter memory |
| SP9019 | EXCESS OFFSET CURRENT UThe U-phase current detection circuit's initial value is abnormal. Replace the spindle amplifier. | Alarm · Internal drive fault |
| SP9020 | EXCESS OFFSET CURRENT VThe V-phase current detection circuit's initial value is abnormal. Replace the spindle amplifier. | Alarm · Internal drive fault |
| SP9032 | SIC-LSI RAM FAULTA fault in the serial transfer LSI in the spindle amplifier. Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| SP9034 | ILLEGAL PARAMETER | Alarm · Setup |
| SP9036 | OVERFLOW ERROR COUNTERThe error counter overflowed. Check whether the position gain is too high, and correct it. | Alarm · Setup |
| SP9037 | ILLEGAL SETTING VELOCITY DETECTORThe speed detector's pulse count parameter is set wrongly. Correct it using the spindle motor parameter manual (B-65280EN). | Alarm · Setup |
| SP9049 | DEF. SPEED IS OVER VALUEIn differential speed mode, the other spindle's speed, converted by the gear ratio, went above the allowed limit. Check whether the calculated differential speed exceeds the maximum motor speed. | Alarm · Setup |
| SP9050 | SYNCRONOUS VALUE IS OVER SPEEDIn spindle synchronisation, the calculated speed command went above the allowed limit. Check whether the calculated value exceeds the maximum motor speed. | Alarm · Setup |
| SP9055 | ILLEGAL POWER LINE | Alarm · Setup |
| SP9070 | ILLEGAL AXIS DATAThe axis data is abnormal: an error in the axis number check. Set the spindle amplifier side to match the connection. | Alarm · Setup |
| SP9071 | SAFETY PARAMETER ERROR | Alarm · Parameter memory |
| SP9074 | CPU TEST ERRORAn error in a CPU test. Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| SP9075 | CRC ERRORAn error in a spindle amplifier CRC test. Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| SP9079 | INITIAL TEST ERRORAn error in the spindle amplifier's initial test. Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| SP9089 | SERIAL SPINDLE ALARM | Alarm · Internal drive fault |
| SP9092 | SERIAL SPINDLE ALARMThe motor speed exceeded the acceleration level for the speed command. Check the sequence: whether SFR or SRV is switched on and off in position control mode. | Alarm · Setup |
| SP9123 | SERIAL SPINDLE ALARMA submodule SW (SSW) error (spindle switching). Replace submodule SW. | Alarm · Internal drive fault |
| SP9131 | SERIAL SPINDLE ALARMA spindle adjustment function alarm. Check the message shown by SERVO GUIDE. | Alarm · Setup |
| SP9137 | SERIAL SPINDLE ALARMA device communication error. Replace the spindle amplifier's control printed circuit board. | Alarm · Internal drive fault |
| OH0700 | LOCKER OVERHEAT | Alarm · CNC control unit |
| OH0701 | FAN MOTOR STOPA fan motor at the top of the CNC control unit has stopped or failed. Replace the fan motor, following the manual's fan replacement section. | Alarm · CNC control unit |
| DS0004 | EXCESS MAXIMUM FEEDRATEThe malfunction prevention function found a command above the maximum speed. | Alarm · Setup |
| DS0005 | EXCESS MAXIMUM ACCELERATIONThe malfunction prevention function found a command above the maximum acceleration. | Alarm · Setup |
| DS0014 | TOOL CHANGE DETECT MACHINE LOCKMachine lock is on for the Z axis during a tool change. | Alarm · Setup |
| DS0015 | TOOL CHANGE DETECT MIRROR IMAGEMirror image is on for the Z axis during a tool change. | Alarm · Setup |
| DS0021 | START ERROR(ONE TOUCH MACRO)A macro program start was refused: feed hold (*SP) is 0, an alarm is active, or the SRN signal is 1. | Alarm · Setup |
| DS0059 | SPECIFIED NUMBER NOT FOUNDA program or sequence number search (or external workpiece number search) found no match, or offset data was requested for a tool number with no data. | Alarm · Setup |
| DS0131 | TOO MANY MESSAGEFive or more external operator or alarm messages were needed at once. | Alarm · Setup |
| DS1150 | A/D CONVERT ALARMThe A/D converter has malfunctioned. | Alarm · Internal drive fault |
| DS1448 | ILLEGAL PARAMETER (D.C.S.)The distance-coded reference mark parameters are invalid (for example APC set, a mark interval of 0, equal intervals, or values out of range). | Alarm · Setup |
| DS1451 | IMPROPER PMC AXIS COMMANDThe PMC axes cannot be controlled in this state. | Alarm · Setup |
| DS2005 | NOW GAIN TUNINGAutomatic operation cannot start while automatic speed gain adjustment is running. Start automatic operation after the adjustment finishes. | Alarm · Setup |
| DS5340 | PARAMETER CHECK SUM ERRORThe parameter checksum does not match the reference checksum because parameters have changed. Restore the parameters, or set the reference checksum again. | Alarm · Parameter memory |
| IE0007 | EXCESS MAXIMUM REV. DATAThe malfunction prevention function found a command above the maximum speed. | Alarm · Setup |
| IE0008 | ILLEGAL ACC/DECThe malfunction prevention function found an acceleration or deceleration error. | Alarm · Setup |
Related
Related pages
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.