An electronic drive that controls the speed and torque of an AC induction motor by varying the frequency and voltage supplied to it.
01 / Definition
What a VFD (Variable Frequency Drive) is
A variable frequency drive controls an AC motor's speed by changing the frequency and voltage it is fed. Inside, a rectifier turns the incoming three-phase AC into DC, a bank of capacitors smooths it into the DC bus, and an inverter of IGBT transistors switches that DC on and off thousands of times a second to build a new AC waveform at whatever frequency the motor should run. Halve the frequency and a four-pole motor runs at roughly half speed, with the voltage reduced in step so the motor's magnetic flux stays right.
A VFD trips to protect itself or the motor, and the trip code is the starting point. Overcurrent trips come from short acceleration ramps, a jammed load or a damaged motor cable. Overvoltage trips come from the motor regenerating energy back into the DC bus when it decelerates faster than friction alone would stop it. Overheating comes from blocked fans and filters or a hot panel. Most of these are cured by settings, braking resistors or cooling, not by replacing the drive. Our fault code pages list every code for common drives from the makers' manuals.
Also called
02 / Anatomy
The parts that matter
The components a technician reaches for when this machine stops working.
Rectifier
Diode or thyristor bridge converting incoming AC to DC; damaged by supply surges.
DC bus capacitors
Smooth the DC; they age with heat and are a common end-of-life failure.
IGBT inverter
Switches the DC to build the output waveform; destroyed by output short circuits.
Control board and keypad
Runs the motor control, protection and parameters.
Cooling fan and heatsink
Remove the heat the power devices make; a failed fan leads to overheat trips.
Braking chopper and resistor
Burn off energy returned by a decelerating motor, preventing overvoltage trips.
03 / Applications
Where it is used
Pumps, fans, conveyors, compressors, mixers and machine-tool spindles — anywhere a motor needs to run at something other than full speed, or needs a soft, controlled start.
04 / Failure modes
How it fails
What actually goes wrong on Indian shop floors, and what each fault looks like to the operator.
FM_01
Overcurrent trips
Short ramps, mechanical overload, motor or cable faults, or wrong motor data.
FM_02
Overvoltage on deceleration
Regenerated energy with no braking resistor or too short a deceleration time.
FM_03
Overheating
Failed fans, clogged filters, a hot panel or overload.
FM_04
Earth faults
Damaged motor insulation or cable, often after moisture gets in.
FM_05
Capacitor and power section failure
Age, heat and supply surges end in a drive that will not power up or blows its input.
05 / Onsite
What our technician checks
A methodical path to root cause, not a scattergun of part swaps.
- 01Read the fault code and fault history before resetting
- 02Check the acceleration and deceleration times against the load
- 03Measure motor and cable insulation with the motor disconnected from the drive
- 04Check the input voltage on all three phases
- 05Check the cooling fan, heatsink and panel ventilation
- 06Check motor nameplate data is entered correctly in the drive
06 / Get it fixed
Related services
The MachineryFix services that cover this equipment.
07 / Questions
Frequently asked questions
Why does my VFD trip on overvoltage when stopping?+
The motor is acting as a generator while it decelerates and pushing energy into the DC bus. Lengthen the deceleration time, enable the drive's overvoltage control, or fit a braking resistor.
Does a VFD save energy?+
On fans and pumps running at reduced flow, usually a lot, because their power falls steeply with speed. On constant-speed loads there is little to save.
Can any motor run on a VFD?+
Most standard induction motors can, but long cables, very low speeds and older winding insulation need care: an output reactor or filter, a separately cooled motor, or inverter-duty insulation.
Why must the motor be disconnected for an insulation test?+
The insulation tester's voltage can damage the drive's output section. Test the motor and cable with the drive disconnected.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007