Industry-Specific
What we do
Temperature control drives quality in plastics processing, and the faults are frequently at the sensor rather than the controller. A thermocouple reading slightly low makes the controller overheat the zone, degrading material while every display looks correct.
We verify thermocouples against a reference rather than trusting the displayed value, because the display is exactly what a faulty sensor corrupts.
New to this equipment? How a Injection Moulding Machine works
Scope
What's covered
- Barrel and die zone temperature control tuning
- Injection and screw drive control repair
- Heater band and thermocouple fault diagnosis
- Hydraulic and electric machine control integration
- Mould safety and clamp interlock verification
- Cycle data logging for process consistency
Questions
Plastics Machinery Electrical: common questions
One zone burns material while showing the correct temperature. Why?+
Almost certainly the thermocouple. A sensor reading below actual causes the controller to add heat until the real temperature is well above setpoint, while the display shows exactly what you asked for. Checking against a reference thermometer confirms it in minutes.
Guides
Related guides
Related
Related services
Written & reviewed by MachineryFix
Last reviewed — questions? Call +91 70133 33007