OH0700 on the FANUC 0i-D is the “LOCKER OVERHEAT” alarm. An alarm stops operation until its cause is removed and it is cleared.
The CNC control unit reported a problem with itself: the temperature in its cabinet, one of its cooling fans, or its own hardware. The machine stops because the control cannot guarantee correct operation.
- Code
- OH0700
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- CNC control unit
01 / Causes
What causes OH0700
- The ambient temperature around the CNC control unit is abnormally high; the temperature monitor is on the main board. The limit is 58°C for the LCD-mounted type and 55°C for the stand-alone type.
02 / Checks
What to check for OH0700
In the order FANUC gives them.
- 01Bring the cabinet temperature within range: 0 to 58°C (LCD-mounted) or 0 to 55°C (stand-alone).
- 02If the temperature is clearly normal, the main board may be defective.
03 / Clearing it
How to clear OH0700
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If OH0700 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How cnc control unit faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Check the electrical cabinet: its fans and filters, door seals, panel air conditioner and the temperature inside.
- 02Check the control unit's own fans are turning and free of dust.
- 03Note any message or LED pattern on the control unit, and whether the alarm comes back after a power cycle.
05 / Repair
When OH0700 means a repair
A failed fan is a part to replace. If the cabinet is cool and the fans run but the alarm stays, the control's main board is suspect.
If OH0700 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / Other drives
CNC control unit: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| FANUC 0i-D Program (PS) | PS5303 TOUCH PANEL ERROR |
07 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007