OT0507 on the FANUC 0i-D is the “- OVERTRAVEL ( HARD )” alarm. An alarm stops operation until its cause is removed and it is cleared.
An axis went past a limit: a software stroke limit stored in the control's parameters, or a hardware limit switch at the end of travel. The control stops feed so the slide does not run into its mechanical end.
- Code
- OT0507
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Overtravel
01 / Causes
What causes OT0507
- The negative-direction stroke limit switch was triggered: the machine reached its stroke end.
02 / Checks
What to check for OT0507
In the order FANUC gives them.
The manual gives no specific remedy for OT0507. Work through the general method for overtravel faults below.
Also in the manual
- In automatic operation, feed stops on all axes; in manual operation, only on the axis that tripped.
03 / Clearing it
How to clear OT0507
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If OT0507 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How overtravel faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Note the axis and direction the alarm names, and whether it is a software (stored stroke) or hardware (limit switch) overtravel.
- 02For a software overtravel, check that the program, work offsets and tool offsets put the axis where intended, then jog or hand-wheel it back inside the limit and reset.
- 03For a hardware overtravel, check whether the slide really is at the end of travel. If it is, back it off using the machine builder's overtravel release procedure; if it is not, check the limit switch, its dog, the cable and the input signal on the PMC diagnosis screen.
- 04If the alarm came after an encoder, motor or battery change, confirm the reference position before running a program: a shifted reference makes good programs overtravel.
05 / Repair
When OT0507 means a repair
Usually an operating or program issue. It points to a repair when an axis trips with the slide nowhere near its limit: a failed limit switch, a broken cable or input, or a lost reference position.
If OT0507 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.