SV0404 on the FANUC 0i-D is the “IMPROPER V_READY ON” alarm. An alarm stops operation until its cause is removed and it is cleared.
The servo amplifier's ready signal did not do what the control expected: it did not come on, dropped out during operation, or stayed on when it should be off. The amplifier needs its control power, main power contactor and emergency stop circuit in the right state before it reports ready.
- Code
- SV0404
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Servo ready
01 / Causes
What causes SV0404
- The servo amplifier's ready signal (VRDY) stayed on while the position control's ready signal (PRDY) was off: it stayed on after the CNC switched MCON off, or came on before MCON.
02 / Checks
What to check for SV0404
In the order FANUC gives them.
- 01The servo amplifier may be defective: replace it.
- 02If that does not cure it, replace the axis cards.
03 / Clearing it
How to clear SV0404
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If SV0404 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How servo ready faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Look for another alarm first: a servo, spindle or power supply alarm often drops the ready signal, and that alarm is the one to clear.
- 02Check the emergency stop is released and the main power contactor (MCC) closes, including any external contactor sequence.
- 03Check the breakers and the control power to the power supply and amplifiers.
- 04Check the status LEDs or display on the power supply and each amplifier for their own alarm numbers.
- 05If the power circuit is good, suspect the amplifier, then the axis card in the control.
05 / Repair
When SV0404 means a repair
Once the power, contactor and emergency stop circuit check out, a ready alarm points at the servo amplifier or the control's axis card.
If SV0404 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.