SV5134 on the FANUC 0i-D is the “FSSB:OPEN READY TIME OUT” alarm. An alarm stops operation until its cause is removed and it is cleared.
The drive stopped receiving messages from its controller (a PLC, a fieldbus master, a keypad or a network) within the allowed time. The drive itself is usually fine; the link to it is not.
- Code
- SV5134
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Communication loss
01 / Causes
What causes SV5134
- During initialisation the FSSB could not reach the open-ready state; the manual suspects the axis card.
02 / Checks
What to check for SV5134
In the order FANUC gives them.
- 01Check that the FSSB-related parameters are set correctly.
- 02Check the power supplies of the servo amplifiers on the FSSB.
- 03Replace the axis cards in the CNC.
- 04Replace the optical cables and servo amplifiers on the FSSB one at a time to find the defective one.
03 / Clearing it
How to clear SV5134
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If SV5134 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How communication loss faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Check whether the PLC or master is running and still sending to this drive.
- 02Check the communication cable, connectors and termination, and the screen's earth connection.
- 03Compare the drive's address, baud rate and timeout settings with the master's.
- 04Look for drives, contactors or welders near the cable that could be injecting noise.
05 / Repair
When SV5134 means a repair
If cable, settings and master are all good and only this drive drops out, its communication port or option card may have failed.
If SV5134 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / Other drives
Communication loss: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
07 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007