F7458 on the Siemens SINAMICS V90 is the “EPOS: Reference cam not found” fault. A fault triggers the reaction set for it: OFF1 ramps the motor down, OFF2 lets it coast down, OFF3 stops it quickly as an emergency stop, and NONE takes no action. Each fault page gives the reaction and the acknowledgement type.
The control has lost, or could not establish, the link between where the machine is and what its position detector says. It happens after the absolute encoder's battery backup fails, after an encoder or motor is replaced or disconnected, or when a reference return cannot complete.
- Code
- F7458
- Type
- Fault (stops the drive)
- Drive
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Kind of fault
- Reference position
01 / Causes
What causes F7458
- After the search for reference started, the axis travelled the maximum permitted distance without finding the reference cam.
02 / Checks
What to check for F7458
In the order Siemens gives them.
- 01Check the "reference cam" input.
- 02Check the maximum permitted distance to the reference cam (p2606).
Also in the manual
- Reaction OFF1 (OFF2, OFF3): the motor ramps down. Acknowledgement IMMEDIATELY: it clears as soon as the cause is removed.
03 / Clearing it
How to clear F7458
- Remove the cause first. Then acknowledge the fault on the BOP, with the RESET digital input, or in SINAMICS V-ASSISTANT.
- Each fault has its own acknowledgement type: POWER ON (power the drive off and on after removing the cause), IMMEDIATELY (it clears once the cause is removed), or PULSE INHIBIT (it can only be acknowledged with a pulse inhibit).
- If the cause is not removed, the fault can come back after five seconds with no button pressed.
- Alarms acknowledge themselves.
Clear it once. If F7458 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.
04 / On site
How reference position faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Check the absolute encoder backup battery; replace batteries with the control powered on, so the stored position is not lost.
- 02Check the encoder cable and its connectors on the motor and the amplifier.
- 03Return the axis to its reference position (or set it by the machine builder's procedure for axes without a deceleration dog), then reset.
- 04Before running a program, confirm the position against a known point on the machine.
- 05If the alarm returns with a good battery and cable, check the encoder's supply voltage and the encoder itself.
05 / Repair
When F7458 means a repair
Points to a repair when the battery and cables are good but the position is still lost, or a reference return will not complete: a failing encoder, encoder cable or axis card.
If F7458 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.