Panel failures show up as heat long before they trip: a loose termination, an overloaded busbar, a contactor with worn tips. A control panel AMC finds them with thermal imaging and routine checks, and fixes them in a planned stop instead of a breakdown.
The contract covers the panels you list, from machine control panels to MCCs, PCCs and APFC panels, and every visit is written against the panel in your service record.
Phone answered 24/7
Call at any hour to report a breakdown.
Verified, experienced technicians
Identity checked before a technician is sent to your plant.
01 / Each visit
Control panel preventive maintenance: what each AMC visit covers
Thermal imaging
Terminations, busbars, breakers and contactors are scanned under load, and hot spots are ranked by how urgent they are.
Terminations
Power terminations are re-torqued during a planned stop with the panel isolated, starting with the ones the thermal scan flagged.
Contactors and relays
Contact wear, coil noise and auxiliary contacts are checked, and contactors near the end of their life are listed for replacement.
Breakers and overloads
Breakers are operated where it is safe to do so, and overload relay settings are checked against each motor's full-load current.
Cooling and sealing
Fans, filters and panel air conditioners are cleaned and checked, and door gaskets and cable glands are inspected before the monsoon.
Insulation and earthing
Insulation resistance is tested on outgoing motor feeders when they are isolated, and earth connections in the panel are checked for continuity and corrosion.
APFC panels
Capacitor currents, contactor condition and the controller's power factor readings are checked, since a failed capacitor step shows as a falling power factor.
Drawings and labels
Changes found in the panel are marked up on the drawings and missing labels are noted, so the next fault is traced from paper instead of by tracing wires.
02 / Why
What a control panel AMC prevents
Panel tripping
Overloads, failing breakers and earth leakage, traced from readings rather than reset and forgotten.
Causes & checks →Overload relays tripping
Wrong settings, phase imbalance or a motor going bad, checked against the motor's rating.
Causes & checks →Burnt terminations
A loose lug heats until it burns the terminal or the cable. Thermal imaging finds it while it is only warm.
Monsoon faults
Moisture and dust entering through failed seals, causing tracking and earth faults.
03 / Records
What is kept for every control panel
- Thermal images and readings, visit by visit
- Breaker and overload settings for each feeder
- Contactor and component replacement history
- Insulation readings on motor feeders
- Open items and the planned stop they are scheduled for
04 / How it works
How a control panel AMC is set up
Contracts are written for plants in and around Hyderabad's industrial areas. For plants elsewhere in India, send the equipment list and location and we will say what can be covered.
- 01Send the list of equipment you want covered and where the plant is.
- 02A walk-through records each unit, its condition and its breakdown history.
- 03You get a written scope, the number of visits and a quote, and approve them before the contract starts.
- 04Visits happen on the agreed dates and each ends with a report. Breakdowns on covered equipment are attended ahead of one-off requests.
- 05At renewal the scope is reviewed against what actually failed during the year.
Makes
control panel makes we work on
Questions
Control Panel AMC: common questions
What does a control panel AMC include?+
Scheduled visits with the thermal imaging, termination, contactor, breaker, cooling and sealing checks agreed for each panel, plus labour for attending breakdowns on the covered panels. Parts are normally quoted when they are needed, unless the contract includes them.
Is this the same as an electrical panel AMC?+
It covers the industrial panels that run your machines: machine control panels, MCCs, PCCs and APFC panels. Anything else you want included is discussed at the walk-through and written into the scope.
Do the checks need a shutdown?+
Thermal imaging and most visual checks are done with the panel running and loaded, which is when hot spots show. Re-torquing, insulation tests and work inside live sections are planned into your scheduled stops.
How often should panels be checked?+
Panels in dusty or hot areas, or ones feeding critical machines, need more frequent visits. In Hyderabad a thermal scan before the summer and a sealing check before the monsoon are worth scheduling every year. The number of visits is written into the contract.