Most drive failures build up for months: a fan slows, dust packs the heat sink, the DC bus capacitors age, a power terminal loosens and heats. A VFD AMC puts those on a checklist, so the drive is cleaned, measured and backed up before it trips in the middle of a shift.
The contract covers the drives you list, of any make and size, at the intervals agreed for each. Every visit is written against the drive in your service record.
Phone answered 24/7
Call at any hour to report a breakdown.
Verified, experienced technicians
Identity checked before a technician is sent to your plant.
01 / Each visit
VFD preventive maintenance: what each AMC visit covers
Cooling and heat sink
Fans are checked for speed and noise, and heat sinks and filters are cleaned. Dust and failed fans are among the most common causes of overheating trips.
DC bus capacitors
Bus voltage and ripple are measured and the capacitors are inspected for bulging or leakage. Their age is tracked against the maker's guidance, so replacement is planned rather than forced by a failure.
Parameter backup
Drive parameters are saved to the keypad or software and kept in the service record, so a replacement drive can be set up from the saved file instead of from memory.
Fault history
The drive's fault log is read and compared with earlier visits. Repeated overcurrent, overvoltage or earth fault trips point to the motor, cable, braking circuit or supply long before the drive itself fails.
Power connections and supply
Input and output terminals are checked for heat under load, input voltage balance is measured, and terminals are re-torqued during a planned stop with the drive isolated.
Braking circuit
Braking resistors and choppers are checked on drives that stop heavy loads, where a failed resistor shows up as overvoltage trips on deceleration.
Motor and cable insulation
Motor insulation is tested with the drive disconnected, since an insulation tester connected to the drive output can damage it. Falling readings warn of an earth fault before it trips.
Spare drives on the shelf
Drives stored unpowered for a long time can need their DC bus capacitors reformed before use, following the maker's procedure. Spares are logged so this is done before they are needed.
02 / Why
What a VFD AMC prevents
Overheating trips
Blocked heat sinks and slow fans, worst through the April to June heat. Cleaning intervals are set from what each visit finds.
Earth fault trips
Usually the motor or its cable, not the drive. Insulation readings on each visit show the decline.
Causes & checks →Overvoltage on deceleration
A failed braking resistor or a deceleration time set too short for the load.
Causes & checks →Nuisance trips
Loose connections, supply dips and wrong parameters, traced from the fault history instead of reset and forgotten.
Causes & checks →03 / Records
What is kept for every VFD
- Parameter backups for every drive, with dates
- Make, model, rating, firmware and serial number
- Fan and capacitor age, and when replacement is due
- Fault history, readings and work done on each visit
- A critical-spares list, including stored spare drives
04 / How it works
How a VFD AMC is set up
Contracts are written for plants in and around Hyderabad's industrial areas. For plants elsewhere in India, send the equipment list and location and we will say what can be covered.
- 01Send the list of equipment you want covered and where the plant is.
- 02A walk-through records each unit, its condition and its breakdown history.
- 03You get a written scope, the number of visits and a quote, and approve them before the contract starts.
- 04Visits happen on the agreed dates and each ends with a report. Breakdowns on covered equipment are attended ahead of one-off requests.
- 05At renewal the scope is reviewed against what actually failed during the year.
Makes
VFD makes we work on
Questions
VFD AMC Service: common questions
What does a VFD AMC include?+
Scheduled visits with cleaning, fan and capacitor checks, parameter backups, a fault history review and thermal checks of the power connections, plus labour for attending breakdowns on the covered drives. Parts such as fans and capacitors are normally quoted when they are needed, unless the contract includes them.
How often should a VFD be serviced?+
It depends mainly on dust, heat and duty. A drive in a dusty plant or a hot panel needs cleaning far more often than one in a clean, cooled room, and the interval is set from what each visit finds. The number of visits is written into the contract.
When should drive fans and capacitors be replaced?+
Makers give a design life for both, and it depends heavily on temperature and load; the manual or the drive's own monitoring parameters state it for each model. The AMC tracks their age and condition so replacement is planned for a stop instead of forced by a failure.
Can the AMC cover drives of different makes and sizes?+
Yes. Siemens, ABB, Schneider, Allen-Bradley, Mitsubishi, Delta, Yaskawa and other drives can sit in the same contract, from small machine drives to large ones on pumps and fans.
Related