DS0306 on the FANUC 0i-D is the “APC ALARM: BATTERY VOLTAGE 0” alarm. An alarm stops operation until its cause is removed and it is cleared.
The control has lost, or could not establish, the link between where the machine is and what its position detector says. It happens after the absolute encoder's battery backup fails, after an encoder or motor is replaced or disconnected, or when a reference return cannot complete.
- Code
- DS0306
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Reference position
01 / Causes
What causes DS0306
- The absolute position detector's battery has dropped too low to hold data, or the Pulsecoder was powered for the first time.
02 / Checks
What to check for DS0306
In the order FANUC gives them.
- 01If it recurs after a power cycle, the battery or its cable is defective.
- 02Replace the battery with the machine powered on, so the stored position is kept.
03 / Clearing it
How to clear DS0306
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If DS0306 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How reference position faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Check the absolute encoder backup battery; replace batteries with the control powered on, so the stored position is not lost.
- 02Check the encoder cable and its connectors on the motor and the amplifier.
- 03Return the axis to its reference position (or set it by the machine builder's procedure for axes without a deceleration dog), then reset.
- 04Before running a program, confirm the position against a known point on the machine.
- 05If the alarm returns with a good battery and cable, check the encoder's supply voltage and the encoder itself.
05 / Repair
When DS0306 means a repair
Points to a repair when the battery and cables are good but the position is still lost, or a reference return will not complete: a failing encoder, encoder cable or axis card.
If DS0306 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / Other drives
Reference position: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| FANUC 0i-D Program (PS) | PS0090 REFERENCE RETURN INCOMPLETE · PS0091 MANUAL REFERENCE POSITION RETURN IS NOT PERFORMED IN FEED HOLD · PS0092 ZERO RETURN CHECK (G27) ERROR · PS0224 ZERO RETURN NOT FINISHED · PS0301 RESETTING OF REFERENCE RETURN IS INHIBITED · PS0302 SETTING THE REFERENCE POSITION WITHOUT DOG IS NOT PERFORMED |
07 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.