PS0090 on the FANUC 0i-D is the “REFERENCE RETURN INCOMPLETE” alarm. An alarm stops operation until its cause is removed and it is cleared.
The control has lost, or could not establish, the link between where the machine is and what its position detector says. It happens after the absolute encoder's battery backup fails, after an encoder or motor is replaced or disconnected, or when a reference return cannot complete.
- Code
- PS0090
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Reference position
01 / Causes
What causes PS0090
- A reference return could not complete: the one-rotation signal was not received at least once while the axis moved toward the reference position fast enough for a positional deviation (diagnosis No. 300) of 128 pulses or more.
- The return started too close to the reference position, the speed was too low, or the Pulsecoder supply voltage is low or the Pulsecoder has failed.
02 / Checks
What to check for PS0090
In the order FANUC gives them.
- 01Check diagnosis No. 300 during the return: if below 128, raise the speed (parameters No. 1420, 1424, 1425 and the servo loop gain No. 1825, plus the rapid traverse override signals).
- 02Check that the motor turns more than one revolution at that speed before reaching the reference position; if not, start the return further away.
- 03Measure the Pulsecoder supply on its circuit board: it must be above 4.75 V.
- 04If the voltage is good, replace the Pulsecoder or the motor, then set the reference position again.
Also in the manual
- With parameter No. 2000 bit 0 (PLC0) at 1, a deviation of 1280 pulses or more is needed. Parameter No. 1836 can lower the minimum deviation below 128.
03 / Clearing it
How to clear PS0090
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If PS0090 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How reference position faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Check the absolute encoder backup battery; replace batteries with the control powered on, so the stored position is not lost.
- 02Check the encoder cable and its connectors on the motor and the amplifier.
- 03Return the axis to its reference position (or set it by the machine builder's procedure for axes without a deceleration dog), then reset.
- 04Before running a program, confirm the position against a known point on the machine.
- 05If the alarm returns with a good battery and cable, check the encoder's supply voltage and the encoder itself.
05 / Repair
When PS0090 means a repair
Points to a repair when the battery and cables are good but the position is still lost, or a reference return will not complete: a failing encoder, encoder cable or axis card.
If PS0090 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / Other drives
Reference position: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| FANUC 0i-D Program (PS) | PS0090 REFERENCE RETURN INCOMPLETE · PS0091 MANUAL REFERENCE POSITION RETURN IS NOT PERFORMED IN FEED HOLD · PS0092 ZERO RETURN CHECK (G27) ERROR · PS0224 ZERO RETURN NOT FINISHED · PS0301 RESETTING OF REFERENCE RETURN IS INHIBITED · PS0302 SETTING THE REFERENCE POSITION WITHOUT DOG IS NOT PERFORMED |
07 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007