SP9003 on the FANUC 0i-D is the “DC-LINK FUSE IS BROKEN” alarm. An alarm stops operation until its cause is removed and it is cleared.
The drive's own electronics reported a problem: a self-test, a processor, an internal link or the power module's identification. There is nothing in the machine to fix.
- Code
- SP9003
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Internal drive fault
01 / Causes
What causes SP9003
- The power supply is ready (shows 00) but the spindle amplifier's DC link voltage is too low: the DC link fuse in the amplifier has blown, from a damaged power device or a motor ground fault.
02 / Checks
What to check for SP9003
In the order FANUC gives them.
- 01Replace the spindle amplifier.
- 02Check the motor's insulation.
Also in the manual
- The spindle amplifier shows 03 (red LED).
03 / Clearing it
How to clear SP9003
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If SP9003 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How internal drive fault faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01Power-cycle the drive and note whether the fault returns.
- 02Check for electrical noise: screened cables, earthing and an EMC filter where the manual calls for one.
- 03Note the fault value the drive shows with the code; the manufacturer uses it to narrow the cause.
05 / Repair
When SP9003 means a repair
If the fault survives a power cycle, the drive needs a bench repair or replacement.
If SP9003 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.