SP9006 on the FANUC 0i-D is the “THERMAL SENSOR DISCONNECT” alarm. An alarm stops operation until its cause is removed and it is cleared.
The drive has lost the signal from a temperature sensor: the heat sink sensor inside the drive, or the motor's own sensor. Without it the drive cannot protect itself or the motor.
- Code
- SP9006
- Type
- Alarm (stops the machine)
- Control
- FANUC 0i-D, 0i Mate-D
- Kind of fault
- Temperature sensor signal
01 / Causes
What causes SP9006
- The motor's temperature sensor is disconnected.
02 / Checks
What to check for SP9006
In the order FANUC gives them.
- 01Check and correct the parameter.
- 02Replace the feedback cable.
Also in the manual
- The spindle amplifier shows 06 (red LED).
03 / Clearing it
How to clear SP9006
- Remove the cause, then press RESET on the MDI panel.
- PW alarms need the power switched off and on again.
- After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.
Clear it once. If SP9006 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.
04 / On site
How temperature sensor signal faults are traced on site
General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.
- 01For a motor sensor, check its wiring to the drive and measure the sensor's resistance.
- 02For the drive's own heat sink sensor, there is nothing to adjust from outside.
05 / Repair
When SP9006 means a repair
A lost heat sink sensor signal inside the drive needs the unit opened and repaired.
If SP9006 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.
06 / More codes
Other 0i-D codes
Source
FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007