0i-D SP9057: CONV. EX. DECELERATION POW.

SP9057 on the FANUC 0i-D is the “CONV. EX. DECELERATION POW.” alarm. An alarm stops operation until its cause is removed and it is cleared.

The braking resistor is absorbing more energy than its rating allows. The machine is being stopped harder or more often than the resistor was sized for.

Code
SP9057
Type
Alarm (stops the machine)
Control
FANUC 0i-D, 0i Mate-D
Kind of fault
Braking resistor

01 / Causes

What causes SP9057

  • Overload in the regenerative resistor (power supply alarm H): its thermostat tripped or a short-time overload was detected.
  • The regenerative resistor is disconnected or its resistance is abnormal.

02 / Checks

What to check for SP9057

In the order FANUC gives them.

  1. 01Reduce the acceleration and deceleration duty.
  2. 02Check the cooling and the surrounding temperature.
  3. 03If the cooling fan has stopped, or the resistance is abnormal, replace the resistor.

Also in the manual

  • The spindle amplifier shows 57 (red LED).

03 / Clearing it

How to clear SP9057

  • Remove the cause, then press RESET on the MDI panel.
  • PW alarms need the power switched off and on again.
  • After an absolute position alarm such as DS0300, the alarm clears once the axis has returned to its reference position; after an encoder or motor change, the reference position must be set again.

Clear it once. If SP9057 comes straight back, stop resetting and find the cause: repeated resets on servo and spindle alarms can turn a cable or motor fault into a damaged amplifier.

04 / On site

How braking resistor faults are traced on site

General practice for this kind of alarm on CNC machines, in the order a technician works. Switch off and let the servo and spindle amplifiers' DC link discharge before touching terminals.

  1. 01Compare the stopping duty (how often, from what speed, how much inertia) with the resistor's rating.
  2. 02Check the resistor's resistance against the drive manual's minimum.
  3. 03Check the resistor for heat damage and its wiring for loose terminals.

05 / Repair

When SP9057 means a repair

A burnt resistor or a shorted braking transistor in the drive has to be replaced.

If SP9057 keeps returning, send the alarm number, a photo of the alarm screen and what the machine was doing when it stopped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on FANUC CNC systems, and they arrive knowing what to look for.

06 / More codes

Other 0i-D codes

Source

FANUC, FANUC Series 0i-MODEL D / 0i Mate-MODEL D Maintenance Manual, 03, B-64305EN/03, Appendix A.1 and A.3 (alarm lists); chapter 10 (troubleshooting).

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of FANUC and is not its authorised service partner.