AL014 on the Delta ASDA-B2 is the “Reverse limit error” warning. This is a warning: the drive reports it on its WARN output and the servo stays on.
An axis went past a limit: a software stroke limit stored in the control's parameters, or a hardware limit switch at the end of travel. The control stops feed so the slide does not run into its mechanical end.
- Code
- AL014
- Type
- Warning
- Drive
- Delta ASDA-B2
- Kind of fault
- Overtravel
01 / Causes
What causes AL014
- The reverse limit switch is activated.
- The servo system is unstable.
02 / Checks
What to check for AL014
In the order Delta Electronics gives them.
- 01Check whether the limit switch is activated.
- 02Check the control parameters and the inertia ratio; adjust the parameters again, or re-evaluate the motor size.
Also in the manual
- WARN output; the servo stays on. Clears with DI.ARST, by switching the servo off, or when the motor moves back off the limit.
03 / Clearing it
How to clear AL014
This is a warning: the drive reports it on its WARN output and the servo stays on.
If AL014 stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.
04 / On site
How overtravel faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Note the axis and direction the alarm names, and whether it is a software (stored stroke) or hardware (limit switch) overtravel.
- 02For a software overtravel, check that the program, work offsets and tool offsets put the axis where intended, then jog or hand-wheel it back inside the limit and reset.
- 03For a hardware overtravel, check whether the slide really is at the end of travel. If it is, back it off using the machine builder's overtravel release procedure; if it is not, check the limit switch, its dog, the cable and the input signal on the PMC diagnosis screen.
- 04If the alarm came after an encoder, motor or battery change, confirm the reference position before running a program: a shifted reference makes good programs overtravel.
05 / Repair
When AL014 means a repair
Usually an operating or program issue. It points to a repair when an axis trips with the slide nowhere near its limit: a failed limit switch, a broken cable or input, or a lost reference position.
If AL014 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Delta drives, and they arrive knowing what to look for.
06 / Other drives
Overtravel: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens SINAMICS V90 | F7475 EPOS: Target position < start of traversing range · F7476 EPOS: Target position > end of the traversing range · F7481 EPOS: Axis position < software limit switch minus · F7482 EPOS: Axis position > software limit switch plus · F7491 STOP cam minus reached · F7492 STOP cam plus reached |
| Hitachi WJ200 | E83 Positioning range error |
07 / More codes
Other ASDA-B2 codes
Source
Delta Electronics, ASDA-B2 Standard AC Servo Drive User Manual, Revision May 2018, DELTA_IA-ASDA_B2_UM_EN_20180509, Chapter 9, Troubleshooting (9.1 to 9.3).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Delta and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007