AL015 on the Delta ASDA-B2 is the “Forward limit error” warning. This is a warning: the drive reports it on its WARN output and the servo stays on.

An axis went past a limit: a software stroke limit stored in the control's parameters, or a hardware limit switch at the end of travel. The control stops feed so the slide does not run into its mechanical end.

Code
AL015
Type
Warning
Drive
Delta ASDA-B2
Kind of fault
Overtravel

01 / Causes

What causes AL015

  • The forward limit switch is activated.
  • The servo system is unstable.

02 / Checks

What to check for AL015

In the order Delta Electronics gives them.

  1. 01Check whether the limit switch is activated.
  2. 02Check the control parameters and the inertia ratio; adjust the parameters again, or re-evaluate the motor size.

Also in the manual

  • WARN output; the servo stays on. Clears with DI.ARST, by switching the servo off, or when the motor moves back off the limit.

03 / Clearing it

How to clear AL015

This is a warning: the drive reports it on its WARN output and the servo stays on.

If AL015 stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.

04 / On site

How overtravel faults are traced on site

General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.

  1. 01Note the axis and direction the alarm names, and whether it is a software (stored stroke) or hardware (limit switch) overtravel.
  2. 02For a software overtravel, check that the program, work offsets and tool offsets put the axis where intended, then jog or hand-wheel it back inside the limit and reset.
  3. 03For a hardware overtravel, check whether the slide really is at the end of travel. If it is, back it off using the machine builder's overtravel release procedure; if it is not, check the limit switch, its dog, the cable and the input signal on the PMC diagnosis screen.
  4. 04If the alarm came after an encoder, motor or battery change, confirm the reference position before running a program: a shifted reference makes good programs overtravel.

05 / Repair

When AL015 means a repair

Usually an operating or program issue. It points to a repair when an axis trips with the slide nowhere near its limit: a failed limit switch, a broken cable or input, or a lost reference position.

If AL015 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Delta drives, and they arrive knowing what to look for.

06 / Other drives

Overtravel: the same fault on other drives

Each maker numbers this protection differently. Codes from each maker's own manual.

DriveCodes
Siemens SINAMICS V90F7475 EPOS: Target position < start of traversing range · F7476 EPOS: Target position > end of the traversing range · F7481 EPOS: Axis position < software limit switch minus · F7482 EPOS: Axis position > software limit switch plus · F7491 STOP cam minus reached · F7492 STOP cam plus reached
Hitachi WJ200E83 Positioning range error

07 / More codes

Other ASDA-B2 codes

Source

Delta Electronics, ASDA-B2 Standard AC Servo Drive User Manual, Revision May 2018, DELTA_IA-ASDA_B2_UM_EN_20180509, Chapter 9, Troubleshooting (9.1 to 9.3).

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Delta and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

AL015 won't clear? Get a technician who knows the ASDA-B2.

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.