LT-1 on the Yaskawa V1000 is the “Cooling Fan Maintenance Time” alarm. A minor fault or alarm makes the ALM LED flash and the display show the code; the motor does not stop, and the drive returns to normal once the cause is removed. An alarm output can be set on a digital output (H2-oo = 10).
The drive's cooling fan has stopped or is not reporting. Running on without it will lead to an overtemperature trip and shortens the life of the power devices.
- Code
- LT-1
- Type
- Alarm (warning)
- Drive
- Yaskawa V1000
- Kind of fault
- Cooling fan
01 / Causes
What causes LT-1
- The cooling fan has reached 90% of its expected performance life.
02 / Checks
What to check for LT-1
In the order Yaskawa gives them.
- 01Replace the cooling fan and reset the maintenance monitor by setting o4-03 to 0.
Also in the manual
- An alarm output is only given if a digital output is set to H2-oo = 2F.
03 / Clearing it
How to clear LT-1
A minor fault or alarm makes the ALM LED flash and the display show the code; the motor does not stop, and the drive returns to normal once the cause is removed. An alarm output can be set on a digital output (H2-oo = 10).
If LT-1 stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.
04 / On site
How cooling fan faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Check whether the fan turns, and clear dust or fibre jamming it.
- 02Check the fan connector and its supply.
05 / Repair
When LT-1 means a repair
A seized or dead fan is replaced; it is one of the most common wear parts on a drive.
If LT-1 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Yaskawa drives, and they arrive knowing what to look for.
06 / Other drives
Cooling fan: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens SINAMICS G120 | F30059 Internal fan defective · A30049 Internal fan defective |
| Siemens MICROMASTER 440 | F0030 Fan failed |
| Yaskawa A1000 | FAn Internal Fan Fault · LT-1 Cooling Fan Maintenance Time |
| Yaskawa GA500 | LT-1 Cooling Fan Maintenance Time |
| Mitsubishi Electric FR-D700 | FN Fan alarm |
07 / More codes
Other V1000 codes
Source
Yaskawa, YASKAWA AC Drive V1000 Technical Manual, 18F, SIEP C710606 18, 6.4 Fault Detection.
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Yaskawa and is not its authorised service partner.