MachineryFix

AC drive (VFD) · 40 codes

Mitsubishi Electric FR-D700 fault codes

The FR-D700 is Mitsubishi Electric's compact general-purpose inverter (FR-D720, FR-D740, FR-D720S and FR-D710W models), found on conveyors, fans, pumps and small machines across Indian factories.

A tripping FR-D700 shows E. and a short code, such as E.OC1 or E.THM; warnings and messages such as OL, TH or Er1 appear without shutting off the output. Below is every code in Mitsubishi's FR-D700 instruction manual, with its description, check points and corrective actions.

01 / Reading codes

Reading and clearing FR-D700 codes

The operation panel shows a fault as E. followed by a short code, for example E.OC1 (overcurrent during acceleration). The FR-PU04 and FR-PU07 parameter units show a text name instead, such as OC During Acc.

On a fault the inverter trips (shuts off its output) and outputs a fault signal until it is reset. Error messages, warnings and the fan alarm are shown while the inverter keeps its output on.

  • When a fault occurs the inverter trips and outputs a fault signal; warnings, the fan alarm and error messages do not shut off the output.
  • Resetting the inverter clears the electronic thermal relay function's accumulated data.
  • E.OHT (external thermal relay) does not restart the inverter on its own, even if the relay contacts reset automatically: the inverter has to be reset.

02 / Current and earth faults

Current and earth faults

CodeNameKind
OLStall prevention (overcurrent)Alarm · Overcurrent
E.OC1Overcurrent trip during accelerationFault · Overcurrent
E.OC2Overcurrent trip during constant speedFault · Overcurrent
E.OC3Overcurrent trip during deceleration or stopFault · Overcurrent
E.GFOutput side earth (ground) fault overcurrent at startAn earth (ground) fault on the inverter's output (load) side let an earth fault overcurrent flow at start, so the inverter tripped. Check the motor and its cable for an earth fault, and repair it.Fault · Earth fault
E.LFOutput phase lossFault · Output phase loss

03 / Voltage and supply

Voltage and supply

CodeNameKind
oLStall prevention (overvoltage)Alarm · DC bus overvoltage
RBRegenerative brake pre-alarmAlarm · Braking resistor
UVUndervoltageAlarm · DC bus undervoltage
E.OV1Regenerative overvoltage trip during accelerationFault · DC bus overvoltage
E.OV2Regenerative overvoltage trip during constant speedFault · DC bus overvoltage
E.OV3Regenerative overvoltage trip during deceleration or stopFault · DC bus overvoltage
E.ILFInput phase lossFault · Input phase loss
E.BEBrake transistor alarm detectionFault · Braking resistor

04 / Temperature and overload

Temperature and overload

CodeNameKind
THElectronic thermal relay function pre-alarmAlarm · Motor overload or overtemperature
FNFan alarmOn an inverter with a cooling fan, the fan has stopped because of a fault, or runs differently from the Pr. 244 cooling fan operation selection. Check the cooling fan for a fault, and contact Mitsubishi.Alarm · Cooling fan
E.THTInverter overload trip (electronic thermal O/L relay function)Fault · Drive overload
E.THMMotor overload trip (electronic thermal O/L relay function)Fault · Motor overload or overtemperature
E.FINHeatsink overheatFault · Drive overtemperature
E.PTCPTC thermistor operationFault · Temperature sensor signal

05 / Motor and load

Motor and load

CodeNameKind
E.OLTStall prevention stopStall prevention brought the output frequency down to 1 Hz and it stayed there for 3 seconds, so the inverter tripped. Check whether the motor is used under overload, and reduce the load (check the Pr. 22 stall prevention operation level setting).Fault · Motor stall
E.CDOOutput current detection value exceededThe output current exceeded the Pr. 150 output current detection level. Check Pr. 150 (output current detection level), Pr. 151 (signal delay time), Pr. 166 (signal retention time) and Pr. 167 (output current detection operation selection).Fault · Load monitoring

06 / Signals and communication

Signals and communication

CodeNameKind
PSPU stopAlarm · External fault
SASafety stopAlarm · Safety input
E.OHTExternal thermal relay operationFault · External fault
E.PUEPU disconnectionFault · Communication loss
E.SAFSafety circuit faultFault · Safety input

07 / Setup, memory and internal

Setup, memory and internal

CodeNameKind
HOLDOperation panel lockOperation lock mode is set, so operations other than the stop key are invalid. Press the MODE key for 2 seconds to release the lock.Alarm · Setup
LOCDPassword lockedThe password function is active, so displaying and setting parameters is restricted. Enter the password in Pr. 297 (password lock/unlock) to unlock it before operating.Alarm · Setup
Er1Write disable errorAlarm · Setup
Er2Write error during operationAlarm · Setup
Er3Calibration errorThe analog input bias and gain calibration values are too close together. Check the calibration settings C3, C4, C6 and C7.Alarm · Setup
Er4Mode designation errorAlarm · Setup
Err.Inverter resetA reset is being executed through the RES signal, or a reset command from communication or the PU; it also shows when the power is switched off. Turn off the reset command.Alarm · Setup
MTMaintenance signal outputThe inverter's cumulative energisation time has reached the set time: the Pr. 503 maintenance timer is larger than the Pr. 504 maintenance timer alarm output set time. Setting 0 in Pr. 503 (maintenance timer) clears the signal.Alarm · Setup
E.PEParameter storage device fault (control circuit board)Fault · Parameter memory
E.RETRetry count excessOperation could not be resumed within the number of retries set, so the inverter tripped. Find and remove the cause of the fault that came before this one.Fault · Automatic restart limit
E.CPUCPU faultFault · Internal drive fault
E.IOHInrush current limit circuit faultFault · Internal drive fault
E.AIEAnalog input faultFault · Setup

Related

Related pages

Source

Mitsubishi Electric, FR-D700 Instruction Manual, March 2012 (revision D), IB(NA)-0600368ENG-D, 5.3 Causes and corrective actions.

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Mitsubishi Electric and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

FR-D700 fault you can't clear?