MachineryFix

Siemens Servo drive · alarm code

SINAMICS V90 A7478: EPOS: Target position > software limit switch plus

A7478 on the Siemens SINAMICS V90 is the “EPOS: Target position > software limit switch plus” alarm. An alarm takes no action on the motor and acknowledges itself once the cause is gone.

An axis went past a limit: a software stroke limit stored in the control's parameters, or a hardware limit switch at the end of travel. The control stops feed so the slide does not run into its mechanical end.

Code
A7478
Type
Alarm (warning)
Drive
Siemens SINAMICS V90, SIMOTICS S-1FL6
Kind of fault
Overtravel

01 / Causes

What causes A7478

  • In the current traversing operation, the target position is above the software limit switch plus.

02 / Checks

What to check for A7478

In the order Siemens gives them.

  1. 01Correct the target position.
  2. 02Change software limit switch plus (p2581).

03 / Clearing it

How to clear A7478

An alarm takes no action on the motor and acknowledges itself once the cause is gone.

If A7478 stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.

04 / On site

How overtravel faults are traced on site

General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.

  1. 01Note the axis and direction the alarm names, and whether it is a software (stored stroke) or hardware (limit switch) overtravel.
  2. 02For a software overtravel, check that the program, work offsets and tool offsets put the axis where intended, then jog or hand-wheel it back inside the limit and reset.
  3. 03For a hardware overtravel, check whether the slide really is at the end of travel. If it is, back it off using the machine builder's overtravel release procedure; if it is not, check the limit switch, its dog, the cable and the input signal on the PMC diagnosis screen.
  4. 04If the alarm came after an encoder, motor or battery change, confirm the reference position before running a program: a shifted reference makes good programs overtravel.

05 / Repair

When A7478 means a repair

Usually an operating or program issue. It points to a repair when an axis trips with the slide nowhere near its limit: a failed limit switch, a broken cable or input, or a lost reference position.

If A7478 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.

06 / Other drives

Overtravel: the same fault on other drives

Each maker numbers this protection differently. Codes from each maker's own manual.

DriveCodes
Delta ASDA-B2AL014 Reverse limit error · AL015 Forward limit error
Hitachi WJ200E83 Positioning range error

07 / More codes

Other SINAMICS V90 codes

Source

Siemens, SINAMICS V90, SIMOTICS S-1FL6 Operating Instructions, 04/2014, 6SL3298-0AV60-0BP0, 11 Diagnostics (11.2 List of faults and alarms).

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

A7478 won't clear? Get a technician who knows the SINAMICS V90.

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.