A7479 on the Siemens SINAMICS V90 is the “EPOS: Software limit switch minus reached” alarm. An alarm takes no action on the motor and acknowledges itself once the cause is gone.
An axis went past a limit: a software stroke limit stored in the control's parameters, or a hardware limit switch at the end of travel. The control stops feed so the slide does not run into its mechanical end.
- Code
- A7479
- Type
- Alarm (warning)
- Drive
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Kind of fault
- Overtravel
01 / Causes
What causes A7479
- The axis is at the software limit switch minus, and an active traversing block was interrupted.
02 / Checks
What to check for A7479
In the order Siemens gives them.
- 01Correct the target position.
- 02Change software limit switch minus (p2580).
03 / Clearing it
How to clear A7479
An alarm takes no action on the motor and acknowledges itself once the cause is gone.
If A7479 stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.
04 / On site
How overtravel faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Note the axis and direction the alarm names, and whether it is a software (stored stroke) or hardware (limit switch) overtravel.
- 02For a software overtravel, check that the program, work offsets and tool offsets put the axis where intended, then jog or hand-wheel it back inside the limit and reset.
- 03For a hardware overtravel, check whether the slide really is at the end of travel. If it is, back it off using the machine builder's overtravel release procedure; if it is not, check the limit switch, its dog, the cable and the input signal on the PMC diagnosis screen.
- 04If the alarm came after an encoder, motor or battery change, confirm the reference position before running a program: a shifted reference makes good programs overtravel.
05 / Repair
When A7479 means a repair
Usually an operating or program issue. It points to a repair when an axis trips with the slide nowhere near its limit: a failed limit switch, a broken cable or input, or a lost reference position.
If A7479 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.
06 / Other drives
Overtravel: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Delta ASDA-B2 | AL014 Reverse limit error · AL015 Forward limit error |
| Hitachi WJ200 | E83 Positioning range error |
07 / More codes
Other SINAMICS V90 codes
Source
Siemens, SINAMICS V90, SIMOTICS S-1FL6 Operating Instructions, 04/2014, 6SL3298-0AV60-0BP0, 11 Diagnostics (11.2 List of faults and alarms).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007