C2000 S1: Emergency stop for external safety

S1 on the Delta C2000 is the “Emergency stop for external safety” fault. A fault stops the drive's output. On over-current and over-voltage faults the drive closes its output gate at once and the motor coasts to a stop.

The drive's safe torque off inputs are open, so it cannot produce torque. Either the safety circuit is doing its job (an e-stop, a guard), or the inputs are not wired or jumpered.

Code
S1
Type
Fault (stops the drive)
Drive
Delta C2000
Kind of fault
Safety input

01 / Causes

What causes S1

  • The switch between S1 and SCM opened.
  • The short-circuit link between S1 and SCM is not fitted.
  • Interference.
  • A hardware failure.
  • A bad connection of the IO card.
  • The IO card does not match the control board's version.

02 / Checks

What to check for S1

In the order Delta Electronics gives them.

  1. 01Reset the switch and switch the power off and on.
  2. 02Refit the short-circuit link.
  3. 03Check the main-circuit, control-circuit and encoder wiring and grounding, to keep interference out.
  4. 04If S1 stays after switching the power off and on, Delta's instruction is to return the drive to the factory for repair.
  5. 05Check the IO card's pins are not broken, the card is seated on the control board correctly, and its screws are tight.
  6. 06If the IO card does not match the control board's version, contact your local Delta agent or Delta.

Also in the manual

  • Fault ID 73. Resets only after the S1 error is cleared.

03 / Clearing it

How to clear S1

  • Remove the cause first. Then press STOP/RESET on the keypad, or switch on a multi-function input set to 5 (Reset).
  • Most faults can be reset 5 seconds after the fault has cleared. Over-voltage faults reset only once the DC bus is below 90% of the trip level, and overheating faults only once the temperature is 10°C below it.
  • Some faults can only be cleared by switching the power off: the current detection and hardware protection faults (cd1 to cd3, Hd0 to Hd3), the watchdog (WDTT), STO Loss (STL1 to STL3) and the CPU error (TRAP).
  • After resetting, if the keypad returns to its main page and shows no fault after ESC, the fault is cleared.

Clear it once. If S1 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.

04 / On site

How safety input faults are traced on site

General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.

  1. 01Check the e-stop, guard switches and safety relay feeding the safety inputs.
  2. 02If the machine does not use the safety function, check the manufacturer's jumper is fitted and tight.

05 / Repair

When S1 means a repair

Never bypass a working safety circuit. A safety input fault that stays with the circuit healthy needs the drive's control module checked.

If S1 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Delta drives, and they arrive knowing what to look for.

06 / Other drives

Safety input: the same fault on other drives

Each maker numbers this protection differently. Codes from each maker's own manual.

DriveCodes
Siemens SINAMICS G120F01600 STOP A initiated · F01625 Sign-of-life error in the Safety data · F01650 Acceptance test required · F01659 Write task for parameter rejected · F30600 STOP A triggered · A01666 Static 1 signal at the F-DI for safe acknowledgement
Siemens SINAMICS V90F1611 SI CU: Defect detected · A52902 Emergency missing
Allen-Bradley PowerFlex 525F059 Safety Open · F111 Safety Hardware
ABB ACS355F0044 SAFE TORQUE OFF · F0045 STO1 LOST · F0046 STO2 LOST · A2023 EMERGENCY STOP · A2035 SAFE TORQUE OFF
Delta ASDA-B2AL013 Emergency stop
Hitachi WJ200E37 Safe Stop
Schneider Electric Altivar ATV320SAFF Safety function detected error
Yaskawa V1000Hbb Safe Disable Signal Input · HbbF Safe Disable Signal Input
Yaskawa A1000Hbb Safe Disable Signal Input · HbbF Safe Disable Signal Input
Yaskawa GA500SCF Safety Circuit Fault · SToF Safe Torque OFF Hardware
Mitsubishi Electric FR-D700E.SAF Safety circuit fault · SA Safety stop

07 / More codes

Other C2000 codes

Source

Delta Electronics, C2000 Series User Manual, Issued edition 01, firmware V2.05 (2019-02-13), DELTA_IA-MDS_VFD-C2000_UM_EN_20190213, Chapter 14, Fault Codes and Descriptions.

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Delta and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

S1 won't clear? Get a technician who knows the C2000.

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.