F31130 on the Siemens SINAMICS V90 is the “Zero mark and position error from the coarse synchronization” fault. A fault triggers the reaction set for it: OFF1 ramps the motor down, OFF2 lets it coast down, OFF3 stops it quickly as an emergency stop, and NONE takes no action. Each fault page gives the reaction and the acknowledgement type.
The speed or position feedback from the encoder is missing or does not agree with what the drive expects.
- Code
- F31130
- Type
- Fault (stops the drive)
- Drive
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Kind of fault
- Encoder signal
01 / Causes
What causes F31130
- After the pole position was initialised (from track C/D, Hall signals or pole position identification), the zero mark was found outside the permissible range, so fine synchronisation did not happen.
02 / Checks
What to check for F31130
In the order Siemens gives them.
- 01Check the encoder cables are routed to EMC rules.
- 02Check the plug connections.
- 03If a Hall sensor stands in for track C/D, check its connection.
- 04Check the connection of track C or D.
- 05Replace the encoder or the encoder cable.
Also in the manual
- Reaction ENCODER: an encoder fault, which causes OFF2: the motor coasts down. Acknowledgement PULSE INHIBIT: it can only be acknowledged with a pulse inhibit.
- For distance-coded encoders, the test runs after two zero marks have been passed.
03 / Clearing it
How to clear F31130
- Remove the cause first. Then acknowledge the fault on the BOP, with the RESET digital input, or in SINAMICS V-ASSISTANT.
- Each fault has its own acknowledgement type: POWER ON (power the drive off and on after removing the cause), IMMEDIATELY (it clears once the cause is removed), or PULSE INHIBIT (it can only be acknowledged with a pulse inhibit).
- If the cause is not removed, the fault can come back after five seconds with no button pressed.
- Alarms acknowledge themselves.
Clear it once. If F31130 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.
04 / On site
How encoder signal faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Check the encoder cable and connectors, and that the screen is earthed at the right end.
- 02Check the encoder's supply voltage.
- 03Check the encoder settings (type, pulses per revolution) in the drive.
05 / Repair
When F31130 means a repair
A damaged encoder or cable is replaced; a drive encoder input that has failed needs the drive repaired.
If F31130 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.
06 / Other drives
Encoder signal: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens MICROMASTER 440 | F0090 Signal loss, encoder · A0590 Alarm, no signals from the speed encoder |
| Allen-Bradley PowerFlex 525 | F091 Encoder Loss |
| ABB ACS355 | F0023 ENCODER ERR · A2024 ENCODER ERROR |
| Delta VFD-E | PGEr PG feedback signal error |
| Delta C2000 | PGF1 PG feedback error · PGF2 PG feedback loss · PGF3 PG feedback stall · PGF4 PG slip error · PGF5 Hardware error of PG card · AboF PG ABZ line off |
| Delta ASDA-B2 | AL004 Motor combination error · AL011 Encoder error · AL018 Abnormal signal output · AL024 Encoder initial magnetic field error · AL025 The internal of the encoder is in error · AL026 Unreliable internal data of the encoder |
| Hitachi WJ200 | E80 Encoder disconnection |
| Schneider Electric Altivar ATV320 | SPF Encoder feedback loss error |
| Yaskawa V1000 | dEv Speed Deviation (for Simple V/f with PG) · oS Overspeed (Simple V/f with PG) · PGo PG Disconnect (for Simple V/f with PG) |
| Yaskawa A1000 | dEv Speed Deviation · dv1 Z Pulse Fault · dv2 Z Pulse Noise Fault Detection · dv3 Inversion Detection · dv4 Inversion Prevention Detection · oS Overspeed |
| Yaskawa GA500 | dEv Speed Deviation · oS Overspeed · PGo Encoder (PG) Feedback Loss |
| Siemens MICROMASTER 430 | F0090 Signal loss, encoder · A0590 Alarm, no signals from the speed encoder |
07 / More codes
Other SINAMICS V90 codes
Source
Siemens, SINAMICS V90, SIMOTICS S-1FL6 Operating Instructions, 04/2014, 6SL3298-0AV60-0BP0, 11 Diagnostics (11.2 List of faults and alarms).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007