RB on the Mitsubishi Electric FR-D700 is the “Regenerative brake pre-alarm” alarm. Error messages, warnings and the fan alarm are shown while the inverter keeps its output on.
The braking resistor is absorbing more energy than its rating allows. The machine is being stopped harder or more often than the resistor was sized for.
- Code
- RB
- Type
- Alarm (warning)
- Drive
- Mitsubishi Electric FR-D700, FR-D720, FR-D740, FR-D720S, FR-D710W
- Kind of fault
- Braking resistor
01 / Causes
What causes RB
- The regenerative brake duty reached 85% or more of the Pr. 70 special regenerative brake duty value. If it reaches 100%, a regenerative overvoltage trip (E.OV_) occurs.
02 / Checks
What to check for RB
In the order Mitsubishi Electric gives them.
- 01Check the brake resistor duty is not too high.
- 02Check the Pr. 30 regenerative function selection and Pr. 70 special regenerative brake duty settings are correct.
- 03Lengthen the deceleration time.
Also in the manual
- Mitsubishi lists this as a warning: the inverter's output is not shut off.
- With Pr. 70 at its initial value 0 this warning does not occur. The RBP output signal can be assigned to a terminal (Pr. 190, Pr. 192 or Pr. 197 set to 7 or 107).
03 / Clearing it
How to clear RB
Error messages, warnings and the fan alarm are shown while the inverter keeps its output on.
If RB stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.
04 / On site
How braking resistor faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Compare the stopping duty (how often, from what speed, how much inertia) with the resistor's rating.
- 02Check the resistor's resistance against the drive manual's minimum.
- 03Check the resistor for heat damage and its wiring for loose terminals.
05 / Repair
When RB means a repair
A burnt resistor or a shorted braking transistor in the drive has to be replaced.
If RB keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Mitsubishi Electric drives, and they arrive knowing what to look for.
06 / Other drives
Braking resistor: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens SINAMICS V20 | A535 Braking resistor overload |
| Siemens SINAMICS G120 | F07806 Regenerative power limit exceeded |
| Siemens SINAMICS V90 | A52901 Braking resistor reaches alarm threshold |
| Siemens MICROMASTER 440 | A0535 Brake resistor hot |
| Delta C2000 | bF Brake transistor error |
| Delta ASDA-B2 | AL005 Regeneration error · AL085 Regeneration error |
| Hitachi WJ200 | E06 Braking resistor overload protection |
| INVT Goodrive20 (GD20) | bCE Braking unit fault |
| Yaskawa V1000 | oL7 High-Slip Braking oL · rH Braking Resistor Overheat · rr Dynamic Braking Transistor |
| Yaskawa A1000 | boL Braking Transistor Overload Fault · oL7 High Slip Braking oL · rF Braking Resistor Fault · rH Braking Resistor Overheat · rr Dynamic Braking Transistor |
| Yaskawa GA500 | boL Braking Transistor Overload Fault · oL7 High Slip Braking Overload · rF Braking Resistor Fault · rH Braking Resistor Overheat · rr Dynamic Braking Transistor Fault |
| INVT Goodrive200A (GD200A) | bCE Braking unit fault |
| Danfoss VLT Micro Drive FC 51 | Alarm 25 Brake resistor short circuit · Alarm 27 Brake chopper fault · Alarm 28 Brake check failed · Alarm 63 Mechanical brake low |
07 / More codes
Other FR-D700 codes
Source
Mitsubishi Electric, FR-D700 Instruction Manual, March 2012 (revision D), IB(NA)-0600368ENG-D, 5.3 Causes and corrective actions.
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Mitsubishi Electric and is not its authorised service partner.