MachineryFix

Mitsubishi Electric AC drive (VFD) · alarm code

FR-D700 RB: Regenerative brake pre-alarm

RB on the Mitsubishi Electric FR-D700 is the “Regenerative brake pre-alarm” alarm. Error messages, warnings and the fan alarm are shown while the inverter keeps its output on.

The braking resistor is absorbing more energy than its rating allows. The machine is being stopped harder or more often than the resistor was sized for.

Code
RB
Type
Alarm (warning)
Drive
Mitsubishi Electric FR-D700, FR-D720, FR-D740, FR-D720S, FR-D710W
Kind of fault
Braking resistor

01 / Causes

What causes RB

  • The regenerative brake duty reached 85% or more of the Pr. 70 special regenerative brake duty value. If it reaches 100%, a regenerative overvoltage trip (E.OV_) occurs.

02 / Checks

What to check for RB

In the order Mitsubishi Electric gives them.

  1. 01Check the brake resistor duty is not too high.
  2. 02Check the Pr. 30 regenerative function selection and Pr. 70 special regenerative brake duty settings are correct.
  3. 03Lengthen the deceleration time.

Also in the manual

  • Mitsubishi lists this as a warning: the inverter's output is not shut off.
  • With Pr. 70 at its initial value 0 this warning does not occur. The RBP output signal can be assigned to a terminal (Pr. 190, Pr. 192 or Pr. 197 set to 7 or 107).

03 / Clearing it

How to clear RB

Error messages, warnings and the fan alarm are shown while the inverter keeps its output on.

If RB stays on, work through the checks above: an alarm that is ignored often becomes a fault that stops the machine.

04 / On site

How braking resistor faults are traced on site

General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.

  1. 01Compare the stopping duty (how often, from what speed, how much inertia) with the resistor's rating.
  2. 02Check the resistor's resistance against the drive manual's minimum.
  3. 03Check the resistor for heat damage and its wiring for loose terminals.

05 / Repair

When RB means a repair

A burnt resistor or a shorted braking transistor in the drive has to be replaced.

If RB keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Mitsubishi Electric drives, and they arrive knowing what to look for.

06 / Other drives

Braking resistor: the same fault on other drives

Each maker numbers this protection differently. Codes from each maker's own manual.

DriveCodes
Siemens SINAMICS V20A535 Braking resistor overload
Siemens SINAMICS G120F07806 Regenerative power limit exceeded
Siemens SINAMICS V90A52901 Braking resistor reaches alarm threshold
Siemens MICROMASTER 440A0535 Brake resistor hot
Delta C2000bF Brake transistor error
Delta ASDA-B2AL005 Regeneration error · AL085 Regeneration error
Hitachi WJ200E06 Braking resistor overload protection
INVT Goodrive20 (GD20)bCE Braking unit fault
Yaskawa V1000oL7 High-Slip Braking oL · rH Braking Resistor Overheat · rr Dynamic Braking Transistor
Yaskawa A1000boL Braking Transistor Overload Fault · oL7 High Slip Braking oL · rF Braking Resistor Fault · rH Braking Resistor Overheat · rr Dynamic Braking Transistor
Yaskawa GA500boL Braking Transistor Overload Fault · oL7 High Slip Braking Overload · rF Braking Resistor Fault · rH Braking Resistor Overheat · rr Dynamic Braking Transistor Fault
INVT Goodrive200A (GD200A)bCE Braking unit fault
Danfoss VLT Micro Drive FC 51Alarm 25 Brake resistor short circuit · Alarm 27 Brake chopper fault · Alarm 28 Brake check failed · Alarm 63 Mechanical brake low

07 / More codes

Other FR-D700 codes

Source

Mitsubishi Electric, FR-D700 Instruction Manual, March 2012 (revision D), IB(NA)-0600368ENG-D, 5.3 Causes and corrective actions.

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Mitsubishi Electric and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

RB won't clear? Get a technician who knows the FR-D700.

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.