F033 on the Allen-Bradley PowerFlex 525 is the “Auto Rstrt Tries” fault. A fault stops the drive; it will not restart until the fault is cleared.
The drive tried to restart itself the number of times it is allowed to and gave up. The original fault is still there, and it is the one to find.
- Code
- F033
- Type
- Fault (stops the drive)
- Drive
- Allen-Bradley PowerFlex 525, PowerFlex 523
- Kind of fault
- Automatic restart limit
01 / Causes
What causes F033
Rockwell Automation's table names this fault and lists what to do, but gives no separate cause. The checks below are the ones it lists; the section on tracing automatic restart limit faults explains where it usually comes from.
02 / Checks
What to check for F033
In the order Rockwell Automation gives them.
- 01Correct the cause of the fault and clear it manually.
03 / Clearing it
How to clear F033
- Rockwell's parameter A551 [Fault Clear] resets a fault when set to 1 (Reset Fault); setting it to 2 (Clear Buffer) also clears the fault queue.
- Correct the cause first: F033 means the drive has already used up its automatic restart attempts on a fault that is still there.
Clear it once. If F033 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.
04 / On site
How automatic restart limit faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Read the fault history to find the fault that triggered the restarts.
- 02Fix that fault before clearing this one.
05 / Repair
When F033 means a repair
This code is never the root cause on its own.
If F033 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Allen-Bradley drives, and they arrive knowing what to look for.
06 / Other drives
Automatic restart limit: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens SINAMICS V20 | F35 Maximum number of auto restart attempts exceeded |
| Siemens SINAMICS G120 | F07320 Automatic restart aborted · A07321 Automatic restart active |
| Siemens MICROMASTER 440 | F0035 Restart after n |
| ABB ACS355 | A2013 AUTORESET |
| Yaskawa V1000 | SEr Too Many Speed Search Restarts |
| Yaskawa A1000 | SEr Too Many Speed Search Restarts |
| Yaskawa GA500 | SEr Speed Search Retries Exceeded |
| Siemens MICROMASTER 420 | F0035 Restart after n · A0571 Auto restart after fault present |
| Siemens MICROMASTER 430 | F0035 Restart after n · A0571 Auto restart after fault present |
| Mitsubishi Electric FR-D700 | E.RET Retry count excess |
07 / More codes
Other PowerFlex 525 codes
Source
Rockwell Automation, PowerFlex 520-Series Adjustable Frequency AC Drive Quick Start, November 2017, 520-QS001B-EN-E, Fault Codes.
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Allen-Bradley and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007