F0015 on the Siemens MICROMASTER 440 is the “No motor temperature signal” fault. On a fault the inverter switches off and shows the fault code; it will not run until the fault is reset.
The drive has lost the signal from a temperature sensor: the heat sink sensor inside the drive, or the motor's own sensor. Without it the drive cannot protect itself or the motor.
- Code
- F0015
- Type
- Fault (stops the drive)
- Drive
- Siemens MICROMASTER 440
- Kind of fault
- Temperature sensor signal
01 / Causes
What causes F0015
- The motor temperature sensor is short-circuited or open-circuit.
02 / Checks
What to check for F0015
In the order Siemens gives them.
- 01Check the motor temperature sensor and its wiring to the inverter.
Also in the manual
- Once the inverter detects the signal is lost, it switches to protecting the motor with its thermal motor model.
03 / Clearing it
How to clear F0015
- Reset a fault in one of three ways: switch the power off and on, press the Fn button on the BOP or AOP, or use digital input 3 (its default setting).
- Fault codes are stored in r0947 (F0003 is stored as 3), with the fault value in r0949, the time of the fault in r0948 and the number of stored faults in P0952.
- Alarm codes are stored in r2110 (A0503 is stored as 503).
Clear it once. If F0015 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.
04 / On site
How temperature sensor signal faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01For a motor sensor, check its wiring to the drive and measure the sensor's resistance.
- 02For the drive's own heat sink sensor, there is nothing to adjust from outside.
05 / Repair
When F0015 means a repair
A lost heat sink sensor signal inside the drive needs the unit opened and repaired.
If F0015 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.
06 / Other drives
Temperature sensor signal: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens SINAMICS V20 | F12 Inverter temperature signal lost · A507 Inverter temperature signal lost |
| Siemens SINAMICS G120 | F07016 Motor temperature sensor fault · A03520 Temperature sensor fault · A07015 Motor temperature sensor alarm · A30920 Temperature sensor fault |
| ABB ACS355 | F0018 THERM FAIL |
| Delta VFD-E | cF3.4 IGBT overheat (temperature sensor) · cF3.5 Power board overheat (temperature sensor) |
| Delta C2000 | tH1o IGBT temperature detection failure · tH2o Capacitor hardware error |
| Schneider Electric Altivar ATV320 | INFB Internal error 11 (Temperature) · PTFL DI6=PTC probe error |
| Yaskawa A1000 | THo Thermistor Disconnect |
| Siemens MICROMASTER 430 | F0012 No inverter temperature signal · F0015 No motor temperature signal |
| Mitsubishi Electric FR-D700 | E.PTC PTC thermistor operation |
| Danfoss VLT Micro Drive FC 51 | Alarm 11 Motor thermistor over temperature |
07 / More codes
Other MICROMASTER 440 codes
Source
Siemens, MICROMASTER 440 Parameter List, Issue 01/06, 6SE6400-5BB00-0BP0, Section 5, Faults and Alarms.
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007