F01040 on the Siemens SINAMICS G120 is the “Parameters must be saved” fault. A fault generally switches the motor off, and it must be acknowledged before the inverter runs again.
The drive could not read or write its stored parameters, or found them invalid. The drive may start with wrong settings, or refuse to start.
- Code
- F01040
- Type
- Fault (stops the drive)
- Drive
- Siemens SINAMICS G120, CU240B-2, CU240E-2
- Kind of fault
- Parameter memory
01 / Causes
What causes F01040
Siemens's table names this fault and lists what to do, but gives no separate cause. The checks below are the ones it lists; the section on tracing parameter memory faults explains where it usually comes from.
02 / Checks
What to check for F01040
In the order Siemens gives them.
- 01Save the parameters (p0971).
- 02Switch the Control Unit off and on again.
03 / Clearing it
How to clear F01040
- Remove the cause, then acknowledge the fault in one of four ways: through bit 7 of PROFIdrive control word 1 (r2090.7), through a digital input set for acknowledgement, from the operator panel, or by switching the inverter's supply off and on.
- Faults found by the inverter's own monitoring of its hardware and firmware can only be acknowledged by switching the supply voltage off and on.
- Alarms need no acknowledgement: they disappear once the cause is removed.
Clear it once. If F01040 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.
04 / On site
How parameter memory faults are traced on site
General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.
- 01Power-cycle the drive and see whether the fault clears.
- 02If it returns, restore the parameters from a backup, or reset to factory settings and set the drive up again.
- 03Keep a parameter backup of every drive, so this never means guessing the settings.
05 / Repair
When F01040 means a repair
A memory fault that survives a factory reset needs the control board repaired or replaced.
If F01040 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.
06 / Other drives
Parameter memory: the same fault on other drives
Each maker numbers this protection differently. Codes from each maker's own manual.
| Drive | Codes |
|---|---|
| Siemens SINAMICS V20 | F51 Parameter EEPROM fault · F61 SD card parameter cloning failed · F62 Parameter cloning contents invalid · F63 Parameter cloning contents incompatible · F64 Inverter attempted to do an automatic clone during startup · F395 Acceptance test/confirmation pending |
| Siemens SINAMICS V90 | A1019 Writing to the removable data medium unsuccessful · A1032 All parameters must be saved · A1045 Configuring data invalid · A52900 Failure during data copying |
| Siemens MICROMASTER 440 | F0051 Parameter EEPROM fault |
| Allen-Bradley PowerFlex 525 | F048 Params Defaulted · F100 Parameter Chksum · F101 External Storage |
| ABB ACS355 | A5010 Corrupted panel parameter backup file · A5018 Parameter default value is not found · A5025 Software is being uploaded or downloaded · A5029 Memory is not ready · A5040 Parameter download error: the selected set is not in the backup file · A5041 Parameter backup file does not fit into memory |
| Delta VFD-E | cF1.0 Power board CPU write failure · cF1.1 Control board CPU write failure · cF2.0 Power board CPU read failure · cF2.1 Control board CPU read failure |
| Delta C2000 | cF1 EEPROM write error · cF2 EEPROM read error |
| Delta ASDA-B2 | AL017 Abnormal EEPROM · AL099 DSP firmware upgrade |
| Hitachi WJ200 | E08 EEPROM error |
| Schneider Electric Altivar ATV320 | EEF1 EEprom control error · EEF2 EEprom power error |
| INVT Goodrive20 (GD20) | EEP EEPROM operation fault |
| Yaskawa V1000 | CPF06 EEPROM Data Error · Err EEPROM Write Error |
| Yaskawa A1000 | CPF06 EEPROM Memory Data Error · dWF1 EEPROM Memory DriveWorksEZ Data Error · Err EEPROM Write Error |
| Yaskawa GA500 | CPF06 Control Circuit Error (EEPROM memory Data Error) · dWF1 EEPROM Memory DWEZ Data Error · Err EEPROM Write Error · LoG Log Com Error |
| Siemens MICROMASTER 420 | F0051 Parameter EEPROM fault |
| Siemens MICROMASTER 430 | F0051 Parameter EEPROM fault · F0053 I/O EEPROM fault |
| Siemens SINAMICS G110 | F0051 Parameter EEPROM fault · F0055 BOP-EEPROM fault |
| INVT Goodrive200A (GD200A) | EEP EEPROM operation fault |
| Mitsubishi Electric FR-D700 | E.PE Parameter storage device fault (control circuit board) |
| Danfoss VLT Micro Drive FC 51 | Error 86 Copy fail · Error 87 LCP data invalid · Error 88 LCP data not compatible |
07 / More codes
Other SINAMICS G120 codes
Source
Siemens, SINAMICS G120 Converter with the CU240B-2 and CU240E-2 Control Units, Operating Instructions, 04/2018, FW V4.7 SP10, A5E34259001B AF, 8.6 List of alarms and faults (Table 8-7, the most important alarms and faults).
Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.
Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007