SINAMICS G110 F0005: Inverter I2t

F0005 on the Siemens SINAMICS G110 is the “Inverter I2t” fault. On a fault the inverter switches off and shows the fault code (Siemens' reaction STOP II); it will not run until the fault is reset.

The drive's own overload model says it has carried more current, for longer, than its rating allows. The drive is undersized for the duty, or the load has grown.

Code
F0005
Type
Fault (stops the drive)
Drive
Siemens SINAMICS G110
Kind of fault
Drive overload

01 / Causes

What causes F0005

  • The inverter is overloaded.
  • The duty cycle is too demanding.
  • The motor's power (P0307) is more than the inverter can supply (r0206).

02 / Checks

What to check for F0005

In the order Siemens gives them.

  1. 01Check the load duty cycle is within the specified limits.
  2. 02Check the motor power (P0307) matches the inverter power (r0206).

03 / Clearing it

How to clear F0005

  • Reset a fault in one of three ways: switch the power off and on, press the Fn button on the BOP, or use digital input 2 (its default setting).
  • Fault codes are stored in r0947 (F0003 is stored as 3), with the fault value in r0949 (0 when the fault has none).
  • Alarm codes are stored in r2110 (A0503 is stored as 503). An alarm shows as long as its condition lasts and disappears when the condition ends; alarms cannot be switched off.

Clear it once. If F0005 comes straight back, stop resetting and find the cause: repeated resets on current and earth faults can turn a cable fault into a damaged drive.

04 / On site

How drive overload faults are traced on site

General practice for this kind of fault on any drive, in the order a technician works. Isolate the supply and let the DC bus discharge before touching terminals.

  1. 01Record the running current and compare it with the drive's rated current.
  2. 02Look for a change in the load: a dragging bearing, a tighter belt, a heavier product, a blocked impeller.
  3. 03Check acceleration time and boost settings; long periods at high torque add up quickly.

05 / Repair

When F0005 means a repair

If the current is well within the rating and the code keeps returning, the drive's current measurement should be checked on the bench.

If F0005 keeps returning, send the code, a photo of the drive's rating plate and what the machine was doing when it tripped to MachineryFix on WhatsApp or call +91 70133 33007. We match a technician who works on Siemens drives, and they arrive knowing what to look for.

06 / Other drives

Drive overload: the same fault on other drives

Each maker numbers this protection differently. Codes from each maker's own manual.

DriveCodes
Siemens SINAMICS V20F5 Inverter I2t · A505 Inverter I2t
Siemens SINAMICS G120F30005 I2t inverter overload · A07805 Drive: Power unit overload I2t
Siemens SINAMICS V90F30005 Power unit: Overload I2t
Siemens MICROMASTER 440F0005 Inverter I2T · A0505 Inverter I2T
Allen-Bradley PowerFlex 525F064 Drive Overload
Delta VFD-EoL Overload
Delta C2000oL Over load · oL3 Overload protection at low frequency
Hitachi WJ200E38 Low-speed overload protection
INVT Goodrive20 (GD20)OL2 VFD overload
Yaskawa V1000oL2 Drive Overload
Yaskawa A1000oL2 Drive Overload
Yaskawa GA500oL2 Drive Overload
Siemens MICROMASTER 420F0005 Inverter I2t · A0505 Inverter I2t
Siemens MICROMASTER 430F0005 Inverter I2t · A0505 Inverter I2t · A0506 Inverter load duty cycle
INVT Goodrive200A (GD200A)OL2 VFD overload
Mitsubishi Electric FR-D700E.THT Inverter overload trip (electronic thermal O/L relay function)
Danfoss VLT Micro Drive FC 51Alarm 9 Inverter overloaded

07 / More codes

Other SINAMICS G110 codes

Source

Siemens, SINAMICS G110 Parameter List, Issue 11/2004, 6SL3298-0BA11-0BP0, Section 2, Faults and Alarms.

Codes, names, causes and remedies are taken from that edition of the manual and reworded; nothing is added to them. Firmware and manual editions differ, so check your drive's own manual before changing parameters. MachineryFix is independent of Siemens and is not its authorised service partner.

Written & reviewed by MachineryFix — last reviewed — questions? Call +91 70133 33007

F0005 won't clear? Get a technician who knows the SINAMICS G110.

Send the code and what the machine was doing when it tripped. We'll match a technician who works on that drive.